In this study, the mechanical properties of concrete incorporating blast furnace slag with 60 % were analyzed according to CBS-Dust replacement rate. Results indicate that replacement of more than 10 % of CBS-Dust have a positive effect on reducing waste disposal costs and strength improvement
본 연구에서는 슬래그를 다량 치환한 콘크리트의 동결융해 저항성능에 미치는 미세공극의 영향을 검토하였다. 콘크리트는 용선예비처리슬래그가 포함된 고로슬래그 미분말을 0, 40, 70 % 치환하여 제조하였으며 압축강도 특성 및 동결융해 저항성능과 미세공극을 검토하였다. 또한 설계기준강도와 목표공기량을 설정하고, 동결융해 작용에 따른 열화를 확인하기 위하여 재령 14일의 낮은 압축강도로 인한 내력저하를 유도하였다. 실험결과, 설계기준강도를 유사하게 설정하고 목표공기량을 확보하였음에도 불구하고 콘크리트의 미세공극 분포가 상이한 결과를 나타내었다. GGBS70 시험체는 동결융해를 받지 않은 초기 0사이클에서 10~100 nm 크기의 공극량이 가장 적어 공극 내 동결할 수 있는 물의 양이 적을 것으로 판단된다. 이러한 이유로 다른 시험체에 비해 동결팽창압력이 상대적으로 작기 때문에 동결융해 저항성능이 우수한 것으로 판단된다.
As a result of strength test on FA and BFS, FA concrete showed higher increase of strength compared to OPC, when FA4000 and FA5000 were mixed 30%, respectively. For BFS concrete, those mixed with 30% and 50% of BFS8000, respectively, showed higher or equivalent strength compare to OPC. As a result of test of chloride penetration on FA and BFS, diffusion coefficients of concrete mixed with 30% FA4000 and FA5000, respectively, showed to restrain average 6.5% of diffusion coefficient compared to OPC. And in case of BFS concrete, those mixed with BFS6000 and BFS8000, restrained diffusion of chloride ions 253% and 336%, respectively, compared to OPC. Therefore, Mixing 50% of BFS was most efficient in order to maximize restraint of chloride penetration according to metathesis of large amount.
This study examined dynamic and characteristics and chloride penetration of concrete mixed with large amount of FA and BFS, which are considered for positive application to construction fields with purpose of long-tern durability of concrete structures. As a result of strength test on FA and BFS, FA concrete showed higher increase of strength compared to OPC, when FA4000 and FA5000 were mixed 30%, respectively. For BFS concrete, those mixed with 30% and 50% of BFS8000, respectively, showed higher or equivalent strength compare to OPC. As a result of test of chloride penetration on FA and BFS, diffusion coefficients of concrete mixed with 30% FA4000 and FA5000, respectively, showed to restrain average 6.5% of diffusion coefficient compared to OPC. And in case of BFS concrete, those mixed with BFS6000 and BFS8000, restrained diffusion of chloride ions 253% and 336%, respectively, compared to OPC. Therefore, Mixing 50% of BFS was most efficient in order to maximize restraint of chloride penetration according to metathesis of large amount. For relation between compression strength and diffusion coefficient of FA and BFS concrete, as strength increased, diffusion coefficient decreased. In this study, when mixing FA and BFS to concrete for long-run durability and restraint against chloride penetration, for FA, mixing it to concrete with less or equivalent 30% of replacement rate was most efficient. And for BFS, as fineness was higher and mixing it to concrete with less or equivalent 50% of replacement rate, there were results of higher strength compared to OPC and more efficient restraint of chloride ions.
The objective of this paper is to investigate the effect of spreading time of waste cooking oil (WCO) on durability of high volume blast furnace slag concrete. Carbonation and resistance to chloride attack were measured according to spreading time of WCO. WCO was spreaded on the surface of the concrete with different curing condition after demolding. Blast furnace slag with 60% was incorporated into concrete with 45% of W/B. Test results indicated that carbonation and penetration resistance of chloride attack had favorable results with the condition of 28days water curing and spreading WCO.
Comparing with using ordinary Portland cement, using blast furnace slag as binder in concrete shows low resistance for carbonation phenomenon. In this research, we focus on carbonation of high volume blast furnace-blended concrete, analysis the reason and find a more efficient method which comparing with using ordinary Portland cement, using FC shows better effort on concrete carbonate resistant.