        1.
        2012.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        두 개의 간헐반응조, 막분리조, 탈기조로 구성된 생물학적 MBR고도처리 공정에 동일한 유입수량과 수질의 하수가 유입되는 경우 운전 온도 및 SRT (Sludge Retention Time)변화에 따른 질소제거 특성을 컴퓨터 시뮬레이션을 통해 파악하였다. SRT가 25일이고 운전온도가 25℃인 경우 간헐반응조를 간헐폭기 시키는 경우에 운전온도 13℃의 59%에서 31%로 질소제거효율이 급격히 떨어지는데, 이는 운전온도 13℃에 비해서 간헐반응조의 RBO (Readily Biodegradable Organic) 농도가 낮아져서 발생한 현상으로 파악되었다. 운전온도 25℃에서 SRT를 12.6일로 운전하는 경우 간헐반응조 RBO농도는 증가하고 질소제거 효율은 회복되었다. 간헐반응조를 갖는 MBR시스템에서 SRT와 운전온도가 간헐반응조 RBO농도에 미치는 영향은 좀더 깊게 연구되어야 한다.
        4,500원
        2.
        2004.07 KCI 등재 서비스 종료(열람 제한)
        This study was conducted to remove organics and nutrients using 2 stage intermittent aeration reactor. First reactor, using suspended microbial growth in intermittent aeration instead of anaerobic reactor in the typical BNR process, used minimum carbon source to release P, and it was possible to reduce ammonia loading going to second reactor. In the second reactor, using moving media intermittent aeration, it was effective to reduce nitrate in non-aeration time by attached microorganisms having long retention time. In aeration time, nitrification and P uptake were taken place simultaneously. From the experiment, two major results were as follows. First, the removal of organics was more than 90%, and optimum aeration/non-aeration time ratio for organic removal was corresponded with aeration/non-aeration time ratio for nitrogen removal. Second, in the first reactor, optimum aeration/non-aeration time ratio was 15/75 (min.) because it was necessary to maintain 75 min. of non-aeration time to suppress of impediment of return nitrate and to lead release of phosphate. In the second reactor, optimum aeration/non-aeration time ratio was 45/90 (min.).
        3.
        2003.01 KCI 등재 서비스 종료(열람 제한)
        This study was carried out to obtain the operating characteristics of SMMIAR process for biological nitrogen·phosphorus removal. SMMIAR was operated at HLR(Hydraulic loading rate) of 39.6, 52.8, 63.4 and 79.2ℓ/㎡/d respectively and the operating parameters such as intermittent aeration time ratio of aerobic/anoxic, DO and microorganism concentration were changed to confirm the optimum operating condition. The concentrations of the wastewater BOD, TN(Total nitrogen) and TP(Total phosphorus) were 150, 30 and 7.5㎎/ℓ respectively. Achieving better removal efficiencies of BOD, TN and TP up to 90, 85.4 and 95.4% respectively, we must keep in operation condition of SMMIAR by 0.75 of time ratio of aerobic/anoxic and by minimum 45 minutes of oxic period simultaneously.