검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 2

        1.
        2005.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In the June, 1991, there was the explosion in which methanol rectified column as a part of the new surface active agent's manufacturing processes. The type of explosion was estimated as the 'detonation'. The methanol rectified column was ruined, and broken pieces of the column were scattered within 900m. Also, there were victims such as the two deads and thirteen wounded persons. The cause of the explosion was heat explosion by being concentrated locally from 0.1% to several tens% of supply fluid at Metal Hydroperoxide, which was produced by methanol and hydrogen peroxide used as the bleach of surface active agent, during the operation stoppage process of methanol rectified column.
        4,800원
        2.
        2005.05 구독 인증기관 무료, 개인회원 유료
        1991년 6월 신규 계면활성제 [a-SF]의 제조 공정의 하나인 메탄올 정류탑에 있어서 폭발사고가 발생했다. 폭발 형태는『폭굉』 이였다 라고 판단되어지고 정류탑은 대파되었으며 탑벽 파편은 대강 900m 범위로 비산되었고 사망자 2명, 부상자 13명의 피해를 입었다. 원인물질은 계면활성제의 표백으로 사용하는 메탄올과 과산화수소에 의해 미량 생성한 유기과산화물(Metal Hydroperoxide)에서 정류탑의 운전정지과정 중에 공급액의 부터 수십까지 국부적으로 농축되어져 열 폭발을 일으킨 것으로 추정 되어진다.
        5,100원