검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 8

        1.
        2015.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        It analyzes the new structure and mechanism of organ type accel pedal to have a double curve to obtain a low effort force has been devised an electronic accel pedal consisting of two springs. To confirm the characteristics of effort force on variation of spring constants for two springs, dynamic analyzes were performed by using the ADAMS software program. According to the result of the simulation analysis, new mechanism of organ type accel pedal has an inflection point of the curve of pedal effort force on variation of spring constants, k, in various range of pedal angle.
        4,000원
        2.
        2013.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Electro-accel pedal is needed to raise fuel efficiency by controlled pedal angle signal regardless driver’s willings to fast start or stop pedaling, and to reduce muscle fatigue by designed Ergonomic structure. For this purpose, in this study, we designed new mechanism of accel pedal in a double linkage with two springs to minimize the force of pedaling on main pedal period for HECV in close the future. We have achieved the simulation to dynamic characteristics and experimented to measure the pedal force with proto sample, and confirmed the potentialities this new mechanism.
        4,000원
        3.
        2012.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study was to investigate drivers' postures in different car pedal systems and skilled levels under fatigue. Twenty four subjects participated in this experiment. For three-dimensional analyses, six cameras (Proreflex MCU-240, Qualisys) were used to acquire raw data. The parameters were calculated and analyzed with Visual-3D. In conclusion, ROAs of two leg-pedal system were less than one leg pedal system by pattern analysis. Through statistical tests, skilled levels have effects on ROAs(X, Y, Z) of ankle joint at breaking a pedal and ROAs(Y, Z) of ankle joint at accelerating a pedal. Also, car pedal systems have effects on ROAs(Y, Z) of ankle joint, and ROA(Z) of knee joint at accelerating a pedal. In addition, skilled levels and car pedal systems (cross effects) have an effect on ROA(Z) of ankle joint. These findings suggested that we should improve a present single pedal system.
        4,500원
        4.
        2012.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study was to compare drivers' postures with different car pedal systems and skilled levels. Fourteen subjects participated in this experiment and for three-dimensional analyses, six cameras (Proreflex MCU-240, Qualisys) were used to acquire raw data. The parameters were calculated and analyzed with Visual-3D. In conclusion, the patterns of pelvic, hip, knee and ankle joint angles were different as to pedal systems and skilled levels, and distal joints ROA pelvis have large angles. ROA(range of angle) of a double pedal system was small, but ROA of a single pedal system was large. These findings suggested that we should improve a present single pedal system.
        4,300원
        5.
        2010.05 구독 인증기관 무료, 개인회원 유료
        The purpose of this study was to compare pedaling patterns according to pedal types during driving. Three-dimensional gait analyses were performed from a self-selected pace, and fourteen subjects participated in the three times(the early, middle and last years). Six cameras (Proreflex MCU-240, Qualisys) were used to acquire raw data. The parameters were calculated and analyzed with Visual-3D. In conclusion, most joint - ROM of lower limbs were less than two-foot pedal system. It is necessary that the current pedal system is to be improved.
        4,000원
        6.
        2006.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
          This study determined the optimal positions of the movable steering wheel and pedal systems of industrial vehicle by various body dimensions. The position of objects and starting driving posture were measured by Martin-type anthropometer and goniometer.
        4,000원
        7.
        2001.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        As a part of HMS(Human-Machine System), the car is very important thing in common life. It is also a significant part to study on the controllers of car that is intentively related with all sensibilities during driving. There are lots of controllers on seating buck of the car. However, there are few study on the sensibility analysis of them. Most of all, the foot controller could be easily overlooked because it could be invisible. This study was based on relationship that the controllers fitted to the driving posture in the drivers' sensibility difference of two transmission modes, automatic and manual transmission. The results show the driver's preference driving posture and sensibility in two kinds of transmission cars. Consequently, it should be designed the seating buck for two different types respectively to be taken comfort driving posture and improve the safety for drivers. Also, it could reduce the fatigue and discomfort in the task of driving. The design of the controllers strongly effects on the drivers' response time. hereby this study was accessed to the sensibility of Korean with analyzing the relationship, quantitative data, and sensibility difference between two kinds of transmission cars.
        4,000원
        8.
        2018.10 KCI 등재 서비스 종료(열람 제한)
        방사선사는 일반촬영 시에 다양한 환자를 만나게 된다. 노령환자, 유아 등 몸이 불편한 환자를 검사하게 된다. 소규모의 병·의원에는 방사선사가 혼자 업무를 보는 경우가 자주 발생한다. 이러한 경우 방사선사의 두 손은 환자의 자세를 유지하는데 사용되어지기 때문에 촬영에 있어서 어려움을 느끼게 된다. 본 연구는 이러한 문제점을 극복하고자 진단용 방사선 발생 발판 스위치를 고안하여 실험하였다. 제작한 발판 스위치를 진단용 엑스선 촬영장치에 장착하여 조사선량 재현성 시험, kVp, mAs, 백분율평균오차와 같은 정량적 평가를 실시하였다. 결과적으로 발판 스위치 사용에 대한 정량적 평가는 조사선량 재현성 시험에서 변동계수가 0.05이하로 측정되었고 kVp 시험에서는 백분율 평균오차가 ± 10% 이내로 측정되었다. mAs 시험에서도 백분율 평균오차가 ± 20% 이내로 측정되었다. 이는 진단용 방사선 발생장치의 검사기준 범위에 모두 부합하여 사용상 문제점은 제시되지 않았다. 또한 현재 근무 중인 방사선사를 상대로 유용성에 관한 정성적 평가를 실시하였다. 결론적으로 발판스위치의 엑스선 발생효율의 정량적 평가에서는 실험된 검사가 엑스선 발생장치 장비 기준 범위에 부합하였으며 설문을 통한 평가에서도 먼저 병·의원에서 근무하는 방사선사를 상대로 발판 스위치를 사용한 이후 설문을 통해 발판 스위치에 대한 편리성과 활용성에 대해 설문 실시한 결과는 발판스위치 사용은 임상에서 많은 도움을 줄 수 있는 긍정적인 결과로 나타내었다. 그러므로 진단용 엑스선 촬영용 발판 스위치를 사용하면 방사선 기술자 작업의 신속성과 정확성을 효과적으로 향상 시킬 수 있으므로 의료 서비스 만족도를 높이는 데 효과적으로 사용할 수 있을 것이다.