        1.
        2012.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Because a smart isolation system cannot be used as a base isolation system for tall buildings, top-story or mid-story isolation systems are required. In this study, adaptability of a smart top-story isolation system for reduction of seismic responses of tall buildings in regions of low-to-moderate seismicity has been investigated. To this end, 20-story example building structure was selected and an MR damper and low damping elastomeric bearings were used to compose a smart base isolation system. Artificial earthquakes generated based on design spectrum of low-to-moderate seismicity regions are used for structural analyses. Based on numerical simulation results, it has been shown that a smart top-story isolation system can effectively reduce both structural responses and isolation story drifts of the building structure in low-to-moderate seismicity regions in comparison with a passive top-story isolation system.
        4,000원
        2.
        2010.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 스마트 최상층 면진시스템을 적용한 고층건물의 풍응답 제어성능을 검토해보았다. 이를 위하여 77층 초고층 건물을 예제구조물로 선택하였고 풍동실험을 통해서 얻은 풍하중을 사용하여 수치해석을 수행하였다. 예제구조물의 최상층은 FPS 및 MR 감쇠기로 구성된 스마트 면진시스템을 이용하여 주구조물과 분리된다. 주구조물의 동적응답을 저감시키는 것이 스마트 최상층 면진시스템의 가장 중요한 목표이지만 면진된 최상층의 과도한 응답은 구조물을 불안정하게 만들 수 있다. 따라서, 본 연구에서는 면진된 최상층과 주구조물을 효과적으로 제어하기 위하여 스카이훅제어기를 제어알고리즘으로 사용하였다. 제안된 스마트 최상층 면진시스템의 제어성능을 검토하기 위하여 일반적인 수동 최상층 면진시스템의 제어성능과 비교하였다. 수치해석결과 제안된 스마트 최상층 면진시스템을 이용하면 일반적인 수동 최상층 면진시스템에 비해서 면진층의 변위를 효과적으로 줄이면서도 구조물의 응답을 저감시킬 수 있음을 확인할 수 있었다.
        4,000원
        3.
        2008.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 최상층면진시스템을 적용한 고층건물의 진동제어 가능성을 검토하여 보았다. 이를 위하여 20층 및 50층 건물을 예제구조물로 선택하였고 El Centro 남북방향 성분을 지진하중으로 사용하여 수치해석을 수행하였다. 그리고 인공풍하중을 사용하여 풍하중에 대한 예제구조물의 사용성을 검토하였다. 면진되는 상부층의 수를 변화시켜가면서 구조물의 응답을 평가함으로써 최적의 면진질량에 대해서 검토하였다. 또한 상부층면진시스템의 고유진동주기 변화에 따른 진동제어성능의 변화를 고정기초구조물과 비교하여 검토하였다. 해석결과 최상층면진시스템은 동조질량감쇠기로서 활용될 수 있으며 풍하중 및 지진하중에 대한 고층건물의 동적응답을 효과적으로 저감시킬 수 있었다.
        4,000원
        4.
        2013.09 KCI 등재 서비스 종료(열람 제한)
        In order to reduce seismic responses of a structure, additional dampers and vibration control devices are generally considered. Usually, control performance of additional devices are investigated for optimal design without variation of characteristics of a structure. In this study, multi-objective integrated optimization of structure-smart control device is conducted and possibility of reduction of structural resources of a building structure with smart top-story isolation system has been investigated. To this end, 20-story example building structure was selected and an MR damper and low damping elastomeric bearings were used to compose a smart base isolation system. Artificial earthquakes generated based on design spectrum of low-to-moderate seismicity regions are used for structural analyses. Based on numerical simulation results, it has been shown that a smart top-story isolation system can effectively reduce both structural responses and isolation story drifts of the building structure in low-to-moderate seismicity regions. The integrated optimal design method proposed in this study can provide various optimal designs that presents good control performance by appropriately reducing the amount of structural material and damping device.
        5.
        2013.04 서비스 종료(열람 제한)
        Adaptability of a smart top-story isolation system for reduction of seismic responses of tall buildings in regions of low-to-moderate seismicity has been investigated in this study. To this end, 20-story example building structure was selected and an MR damper and low damping elastomeric bearings were used to compose a smart base isolation system. Artificial earthquakes generated based on design spectrum of low-to-moderate seismicity regions are used for structural analyses.