Recently, the use of transfer slab system has increased greatly. However, several construction problems are being encountered owing to its excessive thickness. Therefore, in this study, a transfer slab system that uses a reverse drop panel, which can utilize the facility space of the pit floor by reducing the transfer slab thickness, was considered. To investigate the shear behavior of transfer slab system that uses the reverse drop panel, the two-way shear strength of transfer slab-column connection with the reverse drop panel was analyzed using nonlinear FE analysis. In addition, the two-way shear strength evaluations of transfer slab with the reverse drop panel conducted using the existing evaluation methods were verified by comparing the strengths predicted by those methods with the results of nonlinear FE analysis.
최근 국내에서는 고층 벽식 아파트 건설 시, 하부 주차공간과 공용공간 확보를 위하여 RC 전이슬래브 시스템을 사용하는 경우가 증가하고 있다. 하지만 두께가 얇은 RC 무량판 슬래브를 위해 개발된 설계방법 및 구조성능평가 방법을 두께가 매우 두꺼운 전이슬래브 구조설계에 그대로 사용하고 있다는 문제점이 있다. 따라서 합리적인 전이슬래브의 구조설계를 위해서는 RC 전이슬래브 시스템의 2면 전단거동 양상에 대한 명확한 분석이 필요하다. 이에 따라 본 연구에서는 전이슬래브의 두께, 콘크리트 강도, 전단경간비, 철근비 등 다양한 설계변수에 따라 비선형 FEM을 이용하여 전이슬래브의 2면 전단거동을 분석 하였다. 또한 비선형 FEM 해석결과와 기존의 2면 전단강도 평가식으로 예측한 전단강도를 비교분석하여 기존 평가식의 전이슬래브 2면 전단강도 평가 유효성을 검토하였다.
In this study, an experimental research was conducted to investigate the effective compressive strengths of slab-column connections with different strengths. From the test results, it was found that the effective compressive strengths of the interior columns completely restrained by slab were similar to the compressive strengths of the columns.
This paper presents the influence factors of heat transfer in a voided slab under fire situation. The effects of a void in a slab on heat transfer are presented and the results are quantitatively analyzed for each influence factor. For this purpose, the finite element analysis method was used to evaluate the influence of the heat transfer factors on the thermal characteristics in a voided slab. Based on these results, the influence factors which have significant difference in the temperature spectrum were derived.
본 연구에서 내부 공간을 확장시키기 위한 평면확장형 공동주택 리모델링에 있어서 기존 슬래브와 신규 슬래브 접합부의 횡방향 하중 전달 성능을 평가하기 위한 실험을 수행하였다. 슬래브의 접합연결재로 후 매립 Dowel 철근을 사용하였다. 기존 슬래브는 철거 예정인 기존 아파트로부터 채취하였으며, 휨성능을 향상시키기 위하여 탄소판(CFRP)으로 보강하였다. 실험결과로부터 후 매립 Dowel 철근으로 접합된 접합부 실험체가 최종파괴 시까지 완전합성거동을 하는 것을 확인하였으며, 충분한 극한성능 및 사용성능을 확보하고 있음을 알 수 있었다.