초록

The purpose of this study was to verify the change in temperature·humidity·perspiration of fire suit when applying phased intensive exercises to fire fighter wearing fire suit. For this study, three male fire fighters took basic physical test and performed 10 minute phased intensive exercises -exercise intensity I (30%VO2max), exercise intensity II (45%VO2max), exercise intensity III (60%VO2max) based on maximum oxygen consumption (VO2max)- wearing fire suit (helmet, boots, air respirator) in treadmill and took a rest. The result of study shows that the temperature in the suit elevated during stabilization period after each exercise intensity, humidity elevated as exercise intensity increased, perspiration elevated as exercise intensity increased.