국내 건축자재별 라돈 방출량 평가 KCI 등재

Investigation of radon emanation of domestic building materials

  • 언어KOR
  • URLhttps://db.koreascholar.com/Article/Detail/291946
구독 기관 인증 시 무료 이용이 가능합니다. 4,000원
실내환경 및 냄새 학회지 (Journal of Odor and Indoor Environment)
한국냄새환경학회 (Korean Society Of Odor Research And Engineering)
초록

The objective of this study is to censure the provision of correct information to the public through investigating radon emanation by building materials that are used in domestic construction environment. Radon emanation has been identified in 10 framing materials and 16 finishing materials of 26 building materials used in the domestic construction-industry. Radon emanation was measured using the closed chamber method based on CR-39 nuclear track detectors(NTDs). On Brick-General in framing materials, the highest radon emanation rates were 0.60028 Bq/ m2·h for surface and 0.00733 Bq/kg·h for mass, while on Ceiling-Tex Cement Plaster in finishing materials. The highest radon emanation rates were 0.47708 Bq/m2·h for surface and 0.05885 Bq/kg·h for mass.

목차
1. 서 론
 2. 연구 방법
  2.1 연구대상
  2.2 라돈 방출량 측정 및 분석방법
 3. 결 과
  3.1 골조자재 라돈방출량
  3.2 마감자재 라돈방출량
 4. 고 찰
 5. 결 론
 감사의 글
 References
저자
  • 이철민(평택대학교 환경융합시스템학과) | Cheolmin Lee Corresponding Author
  • 정순원(국립환경과학원 환경보건연구과) | Soonwon Jung
  • 이동현((주)EHS 기술연구소) | Donghyun Lee
  • 김영범((주)EHS 기술연구소) | Youngbeom Kim
  • 이다정((사)한국라돈협회) | Dajeong Lee
  • 조용석((사)한국라돈협회) | Yongseog Cho
  • 진영화((사)한국라돈협회) | Younghwa Jin