논문 상세보기

비 혼합 2유체 열사이폰의 저온시동 특성에 관한 연구 KCI 등재

A Study on the Frozen Start up Characteristics of the Immiscible

  • 언어KOR
  • URLhttps://db.koreascholar.com/Article/Detail/298836
구독 기관 인증 시 무료 이용이 가능합니다. 4,000원
한국기계항공기술학회지(구 한국기계기술학회지) (Journal of the Korean Society of Mechanical and Aviation Technology)
한국기계항공기술학회(구 한국기계기술학회) (Korean Society of Mechanical Technology)
초록

This study presents design, construction and testing of a immiscible two working fluids thermosyphon with water and FC-40 to prevent freezing of vehicle starting up at temperatures below freezing point of water. The two working fluids thermosyphon was experimentally investigated on the startup characteristics at low temperatures below 0°C and then the thermosyphon was stable during startup and operated reliable at temperature of –30°C. The testing also showed that the performance and characteristics of the two working fluids thermosyphon differ from the charging ratio and mixture ratio of the two working fluids.

목차
1. 서 론
 2. 실험장치 및 실험방법
 3. 실험결과 및 고찰
  3.1 물 히트파이프의 시동 실패 특성
  3.2 비혼합 2유체 히트파이프의 저온시동 특성
  3.3 비혼합 작동유체의 충전율과 체적비의 영향
 4. 결 론
 References
저자
  • 도선엽(Member, Korea Polytechnic University) | S. Y. D o Corresponding author
  • 강환국(Dongeun ATS) | H . K . K ang
  • 박승철(Kroea Polytechnic University) | S. C . Park