Two sewage treatment facilities were selected to identify odor emission characteristics, focusing on volatile organic compounds (VOCs) and sulfur compounds. The complex odor, 5 kinds of sulfur compounds and 23 kinds of VOCs were analyzed from gas and sludge storages. Hydrogen sulfide was detected in the highest concentration and had the highest odor quotient among the odorous compounds monitored in this study, demonstrating that the contribution of hydrogen sulfide to the complex odor reached up to 90%. For VOCs, the overall contribution to the complex odor was not critical but VOCs can sufficiently trigger an odorous sensation because the sum of the odor quotient reached up to 2.89.