논문 상세보기

전기집진장치의 코로나 전류 발생 전극 제작에 따른 추타력 비교에 관한 연구 KCI 등재

The Study of Comparison on Rapping Force on Generation of Corona Discharge Electrode of Electrostatic Precipitator

  • 언어KOR
  • URLhttps://db.koreascholar.com/Article/Detail/365630
서비스가 종료되어 열람이 제한될 수 있습니다.
한국환경과학회지 (Journal of Environmental Science International)
한국환경과학회 (The Korean Environmental Sciences Society)
초록

Rapid industrial development has led to a serious problem of pollution in the industrial sector. With the increasing social need for environmental protection, research on air pollution prevention equipment for reducing pollutants in industrial processes is actively being undertaken. The deterioration of existent, installed facilities, their increased emission rates, and the strengthening of the effluent quality standards make complying with permissible emission standards difficult. In fact, installing new electric precipitators or complementing existent facilities is inevitable. The expansion and complementation of the installed electrical precipitators have led to improvements in dust collection efficiency, shorter working times, and lower costs. Because of its easy installation and simple manufacturing process, the production method with the discharge electrode of an electric precipitator is widely used. The following conclusions were reached by classifying discharge electrodes into four types based on the production method and mutually comparing them by their dust collection efficiency. None of the four types used in this study were damaged by impact. However, we were able to confirm some strain from the compression sites of both type A and type B. Both type B and type C are expected to have greater dust collection efficiencies than the other models due to their large vibration transmissibility. Moreover, the high vibrational energy is expected to cause rapping damage during its operation. Particularly, in the case of type B, some of the strain was found at the end of the compression site. The coupling schemes of both type C and type D are out of vibration transmissibility. On the other hand, the ability to maintain straightness and solidity of the side is regarded as outstanding and stable. Type D has outstanding on-site workability, considering the presence of locking, structural stability, and work conditions. From these experiments, we determined that type C is the most ideal connection method of discharge electrode, considering its construction period of renovation. Type C is inferior to type D with regard to on-site workability. However, type C has outstanding dedusting transmission with regard to the straightness, solidity maintenance, and vibration of shearing stress.

목차
Abstract
 1. 서 론
 2. 재료 및 방법
 3. 결과 및 고찰
  3.1. 외관 검사에 따른 적용성
  3.2. 진동 측정 검사에 따른 적용성
 4. 결 론
 REFERENCES
저자
  • 이강욱(KC한미산업(주)) | Kang-Wuk Lee (KC Hanmi Environment Co., Ltd.)
  • 박정호(경남과학기술대학교 환경공학과) | Jeong-Ho Park (Department of Environmental Engineering, Gyeongnam National University of Science and Technology)
  • 장성호(부산대학교 바이오환경에너지학과) | Seong-Ho Jang (Department of Bio-Environmental Energy, Pusan National University)
  • 임우택(안동대학교 응용화학과) | Woo-Taik Lim (Department of Applied Chemistry, Andong National University)
  • 서정민(부산대학교 바이오환경에너지학과) | Jeong-Min Suh (Department of Bio-Environmental Energy, Pusan National University) Corresponding author