검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 36

        1.
        2022.05 KCI 등재 구독 인증기관 무료, 개인회원 유료
        To solve the pathological problems of the musculoskeletal system based on evidence, a sophisticated analysis of human motion is required. Traditional optical motion capture systems with high validity and reliability have been utilized in clinical practice for a long time. However, expensive equipment and professional technicians are required to construct optical motion capture systems, hence they are used at a limited capacity in clinical settings despite their advantages. The development of information technology has overcome the existing limit and paved the way for constructing a motion capture system that can be operated at a low cost. Recently, with the development of computer vision-based technology and optical markerless tracking technology, webcam-based 3D human motion analysis has become possible, in which the intuitive interface increases the user-friendliness to non-specialists. In addition, unlike conventional optical motion capture, with this approach, it is possible to analyze motions of multiple people at simultaneously. In a non-optical motion capture system, an inertial measurement unit is typically used, which is not significantly different from a conventional optical motion capture system in terms of its validity and reliability. With the development of markerless technology and advent of non-optical motion capture systems, it is a great advantage that human motion analysis is no longer limited to laboratories.
        4,000원
        2.
        2021.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        A normal range of motion is essential for performing activities of daily living. The capsular pattern is the proportional motion restriction in range of motion during passive exercises due to tightness of the joint capsule. Although the capsular pattern is widely referred to in clinical practice, there is no scientific evidence to support the concept. In this review, the appropriateness of the capsular pattern for evaluation of joint pathology was assessed. In the Textbook of Orthopaedic Medicine written by Cyriax, the capsular pattern did not specify how much reduction in angular motion is considered motion restriction. As the definition proposed initially was unclear, different methods have been used in previous studies investigating capsular pattern. In addition, the capsular pattern described all the major joints of the human body, but only the hip joint, knee joint, and shoulder joint were studied in experimental studies. Sensitivity and specificity were reported in one study and were meaningful in specific pathologies (loss of extension to loss of flexion). There was no consensus on the reliability and validity. In summary, the capsular pattern suggested by Cyriax or Kaltenborn is not supported or applies only to certain conditions. Various components around a joint complement each other and provide stability to the joint. It is recommended that the therapist perform multiple assessments rather than rely on a single assessment when evaluating joints.
        4,000원
        3.
        2020.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Background: To prevent or reduce the risk of strain injury, various approaches, including stretching techniques are currently being used. The effect of proprioceptive neuromuscular facilitation (PNF) and static stretching on flexibility has been demonstrated; however, it is not clear which one is superior. Objects: This study aimed to evaluate the differences between the effects of PNF and static stretching performed at various intensities on muscle flexibility. Methods: The maximum voluntary isometric contraction (MVIC) of the hamstrings using the PNF stretching technique was performed in the P100 group, while 70% of the MVIC was performed in the P70 group. The MVIC value obtained during the PNF stretching in both groups was used as a reference for setting the intensity of static stretching. Static stretching was performed at 130% (S130), 100% (S100), and 70% of the MVIC (S70). The active knee extension (AKE) values, defined as the knee flexion angle were measured before stretching (baseline), immediately after stretching (post), and at 3 minutes, 6 minutes, and 15 minutes. Results: PNF stretching produce a greater improvement in flexibility compared with static stretching. Specifically, the ΔAKE was significantly higher in the S100 and S70 groups than in the P100 group at Post. In the comparison of ΔAKE over time in each group, the ΔAKE at Post showed a significant decrease compared to the value at Baseline in the S130 group; however, no significant difference was observed at 6 minutes while a significant increase was noted at 15 minutes. Conclusion: This study found that PNF stretching is more effective than static stretching with respect to increasing and maintaining the flexibility of muscles. In addition, the increase in flexibility at maximal intensity was similar to that observed at submaximal intensity during both PNF and static stretching.
        4,000원
        4.
        2016.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        목 적 : GRAPPA 기법을 이용하는 검사에서 GRAPPA factor는 k-공간 내에 누락시 킬 신호의 양을 결정하고 검사시간을 줄이는 변수이다. 하지만 GRAPPA factor가 증가할수록 영상의 SNR이 저하되고 인공물이 증가하는 제한점이 있다. 따라서 본 연구에서는 GRAPPA factor와 ACS Line 수를 변화시켜 영상 화질과의 상관관계를 평가하여 분석하고자 하였다. 대상 및 방법 : VIBE sequence를 사용하여 GRAPPA factor를 2, 3, 4, 5로 ACS Line의 수는 20, 40, 60, 80, 100, 120로 증가시키고 검사하였다. 화질 평가를 위해 영상의 SNR을 측정하였고 GRAPPA 기법을 이용하지 않은 영상과 GRAPPA 기법을 이용한 영상의 유사성(SSIM)을 평가하였다. 또한 GRAPPA factor를 2, 3, 4, 5로 고정하였을 때 ACS Line과 SNR, ACS Line과 SSIM의 상관관계분석을 실시하였다. 결 과 : GRAPPA factor가 증가 할수록 SNR은 저하되었고 같은 GRAPPA factor의 조건에서 ACS line의 수가 증가 할수록 SNR은 증가되었다. GRAPPA 기법을 이용하지 않은 영상과 GARPPA기법을 이용한 영상의 유사성 평가에서는 GRAPPA factor가 증가 될수록 SSIM은 저하되었고 같은 GRAPPA factor의 조건에서 ACS Line의 수가 증가 될수록 SSIM은 1에 가까워졌다. ACS Line의 수와 SNR의 상관관계분석 결과 GRAPPA factor가 2일 경우 Pearson 상관계수가 0.291, GRAPPA factor가 3일 경우 0.458, GRAPPA factor가 4일 경우 0.779, GRAPPA factor가 5일 경우 0.88로 나타났다. ACS Line의 수와 SSIM의 상관관계분석 결과 GRAPPA factor가 2일 경우 Pearson 상관계수가 0.787, GRAPPA factor가 3일 경우 0.792, GRAPPA factor가 4일 경우 0.918, GRAPPA factor가 5일 경우 0.946로 나타났다. 결 론 : GRAPPA 기법을 이용하는 검사에서 GRAPPA factor를 증가시킬 경우 검사시간이 감소하지만 SNR이 저하되고 인공물이 증가하는 제한점이 있다. 따라서 GRAPPA 기법을 이용하였을 때 검사에 영향을 주지 않은 시간 내에서 ACS Line의 수를 최대로 사용하면 SNR 증강 효과와 더불어 인공물을 개선할 수 있고 GRAPPA factor가 높을 경우 ACS Line의 수를 증가시키면 개선효과가 더 클 것으로 사료된다.
        4,000원
        5.
        2015.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        목 적 : 초음파를 이용한 심장 혈류의 정량적 측정은 관측자의 숙련도에 의해 평가결과가 변화할 수 있는 문제가 있다. 이를 보완하기 위해 자기공명 영상 장치의 위상 대조도 자기공명 영상 기법을 통한 심장 혈류의 정량적 측정이 많이 이용되고 있다. 하지만 아직까지 고자기장(3.0T) 자기공명 영상 장치와 저자기장(1.5T) 자기공명 영상 장치의 측정 오차에 대한 기준이 표준화 되어 있지 않다. 따라서 본 연구에서는 자기장에 따른 심장 혈류의 측정값을 비교하여 분석하고 이에 대한 해결책을 제시하여 검사의 정확성을 향상시키고자 한다. 대상 및 방법 : 심혈관계 질환이 없는 정상의 남자 지원자 15명(평균연령: 35.4±4.10세)을 대상으로 심장 혈류 평가를 실시하였다. 장비는 초음파 Philips IU-21을 이용하여 심장 상행 대동맥의 최대 혈류속도와 평균 혈류량을 측정 하였으며, 자기공명 영상 장치는 GE Signa HDxt 3.0T/1.5T(GE Medical System Milwaikee, Wisconsin, USA)와 8channel cardiac array 코일을 사용하였다. 2D 자기공명 위상 대조도 영상은 상행 대동맥의 S-T juction과 Aortic valve LV에서 각각 시행하였다. 자기장의 세기에 의한 심장혈류의 차이를 비교하기 위해 1.5T와 3.0T 모두에서 shim을 사용하지 않고(NO shim) 검사를 시행하였으며, shimming에 의한 심장 혈류 차이를 평가하기 위해 각각 Auto shim, Local shim, 그리고 두 가지 shim(auto + local: All shim)을 모두 사용한 상태에서 각각 검사를 시행하였다. 결과 분석은 SPSS 20.0을 이용하여 대응표본 검정(Wilcoxon signed-Rank test), 다중회귀분석, 일원분산분석(ANOVA)을 실시하였다. 유의 수준은 0.05미만으로 하였다. 결 과 : 각각 1.5T와 3.0T에서 얻은 혈류 측정값은 서로 유의한 차이를 보였으며(LV AF: z=-3.409, p=0.001 / AA AF: z=-3.239, p=0.001), NO shim LV 1.5T의 혈류 측정값이 초음파의 혈류 측정값과 가장 높은 상관 관계가 있는 것으로 나타났다(t=5.827, p=0.000). 3.0T의 혈류 측정값은 shim을 사용했을 때 NO shim LV 1.5T와 비교해 유의한 차이가 없는 것으로 나타났다. 결 론 : 자기공명 영상 장치를 이용한 심장 혈류 평가에 있어서 자기장이 높은 3.0T에서 측정한 혈류값은 자기장이 낮은 1.5T에서 측정한 결과와 차이가 발생할 수 있다. 따라서 자기공명 영상 장치를 이용한 심장 혈류의 평가는 저자기장(1.5T) 자기공명 영상장치를 사용하거나 자기장이 높은 자기공명 영상장치를 사용할 경우 정확한 혈류 평가를 위해 반드시 shimming을 통해 자기장의 균일도를 개선해야 한다
        4,500원
        6.
        2014.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        목 적 : 좌심실의 기능(left ventricular function)을 정확하게 평가하는 것은 심장 질환을 가진 환자의 임상적 진단이나 치료 전략 및 예후 평가에 있어 매우 중요하다. 본 논문의 목적은 대동맥판막 협착증으로 진단된 환자의 좌심실 기능평가를 dual source computed tomography(DSCT)와 two dimensional-transthoracic echocardiography(2D-TTE)와 비교하여 심장 검사에서 MRI의 활용에 대한 근거자료를 마련하고 우수성을 입증하는 것이다. 대상 및 방법 : 2008년 08월부터 2010년 09월까지, AS로 진단된 환자 중, 2주 이내에 DSCT, 2D-TTE, CMR를 모두 시행한 93명(남성 48명, 여성 45명, 평균연령 57.7세)을 수술 전 비교 평가하였다. EDV, ESV, SV, EF은 M mode를 사용한 2DTTE, threshold-based technique를 사용한 DSCT, 심슨의 방법을 사용한 CMR을 통해 계산하였다. LV 기능의 파라미터에 대한 통계적 분석은 피어슨 상관분석, 다중회귀분석 그리고 CMR 데이터를 독립적으로 분석한 두 명의 방사선사 사이의 관찰자간 일치도를 평가하였으며, 유의수준은 p값 0.05미만을 유의한 것으로 보았다. 결 과 : 총 환자수는 93명(남성 48명, 여성 45명, 평균연령 57.71±13.7, 1.5T MRI 69명, 3.0T MRI 24명) 이었다. EDV, ESV, SV, EF을 위한 CMR과 DSCT는 매우 우수한 상관관계(r=0.93, 0.94, 0.83, and 0.85, 각각, p<0.01)를 나타내었으며, CMR과 2D-TTE는 우수한 상관관계(r=0.81, 0.92, 0.56, and 0.77, 각각, p<0.01)를 보여주었다. DSCT는 CMR에 비해 EDV(130.48ml), ESV(40.74ml), 그리고 SV(89.74ml)에서 낮은 측정치를 보였으나, EF(71.1%)은 높게 나타났다. CMR을 이용한 LV 기능 평가의 관찰자간 일치도 평가에서 매우 높은 상관관계(r=EDV; 0.96, ESV; 0.94, SV; 0.92, EF; 0.84, 각각, p<0.01)를 보였다. 다중회귀분석에서 DSCT의 회귀계수(Β=EDV; 0.91, ESV; 0.72, SV; 0.86, EF; 0.68)는 2D-TTE의 회귀계수(Β=EDV; 0.21, ESV; 0.53, SV; 0.13, EF; 0.32) 보다 높게 나타났으며, 결정계수(r2)는 각각 0.88, 0.91, 0.71, 0.78로 높게 나타났다. 결 론 : 심슨의 방법을 사용한 CMR 측정은 재현성과 우수성이 입증되었다. 따라서 대동맥판막 협착증을 가진 환자의 LV 기능을 평가하기 위해 CMR의 폭 넓은 활용과 많은 연구가 필요할 것으로 사료된다.
        4,000원
        7.
        2014.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        During the fierce competition among the companies, improvement of logistics center managing efficiency is importantly recognized. Among them, studies on improvement of picking work process on about 55% of logistics center managing costs are continuously conducted. And, most of studies focus on analysis on strengths and weaknesses of picking method performable on the stage of logistics center design, etc, so the purposes of this research are to define load location rule by product releasing frequency in logistics managing environment based on conveyer and suggest expected effects by simulation analyzing method to improve picking managing efficiency.
        4,000원
        8.
        2014.04 구독 인증기관 무료, 개인회원 유료
        Recently, Pharmaceutical Logistics Center in the introduction of automated equipment and systems for the efficiency of logistics is very important. However, the base of a distributed logistics, shipment data analysis and process improvement and automation, if not considered as an automated logistics center can not function well in many cases. To do this, we first classify the specific background factors in pharmaceutical environment factor and then develop the automation system model to analyze the factors that affect the pharmaceutical distribution center. We also develop a efficiency of Logistics Center thorough DPS(Digital Picking System), DPC(Digital Picking Cart System), Sorter such as factory automation equipment by improving the process and data analysis.
        4,300원
        12.
        2011.05 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        This paper has relatively high technical standard and experimental skill. The fabrication of TCO film with hightransparency, low resistance and low chromaticity require exact control of several competing factors. This paper has resolvedthese problems reasonably well, thus recommended for publication. Indium tin oxide(ITO) thin films were by D.C. magnetronroll-to-roll sputter system utilizing ITO and SiO2 targets of ITO and SiO2. In this experiment, the effect of D.C. power, windingspeed, and oxygen flow rate on electrical and optical properties of ITO thin films were investigated from the view point ofsheet resistance, transmittance, and chromaticity(b*). The deposition of SiO2 was performed with RF power of 400W, Ar gasof 50sccm and the deposition of ITO, DC power of 600W, Ar gas of 50sccm, O2 gas of 0.2sccm, and winding speed of 0.56m/min. High quality ITO thin films without SiO2 layer had chromaticity of 2.87, sheet resistivity of 400ohm/square, and trans-mittance of 88% and SiO2-doped ITO Thin film with chromaticity of 2.01, sheet resistivity of 709ohm/square, and transmittanceof more than 90% were obtained. As a result, SiO2 was coated on PET before deposition of ITO, their chromaticity(b*) andtransmittance were better than previous results of ITO films. These results show that coating of SiO2 induced arisingchromaticity(b*) and transmittance. If the thickness of SiO2 is controlled, sheet resistance value of ITO film will be expected tobe better for touch screen. A four point probe and spectrophotometer are used to investigate the properties of ITO thin films.
        4,000원
        14.
        2009.07 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        Indium Tin Oxide (ITO) thin films on Polyethylene Terephtalate (PET) substrate were prepared by Roll-to-Roll sputter system with targets of 5 wt% and 10 wt% SnO2 at room temperature. The influence of the chromaticity (b*) and transmittance properties of the ITO Films were investigated. The ITO thin films were deposited as a function of the DC power, rolling speed, and Ar/O2 gas flow ratio, and then characterized by spectrophotometer. Their crystallinity and surface resistance were also analyzed by X-ray diffractometer and 4-point probe. As a result, the chromaticity (b*) and transmittance of the ITO films were broadly dependent on the thickness, which was controlled by the rolling speed. When the ITO films were prepared with the DC power of 300 W and the Ar/O2 gas flow ratio of 30/1 sccm using 10 wt% SnO2 target as a function of the rolling speeds 0.01 through 0.10 m/min, its chromaticity (b*) and transmittance were about -4.01 to 11.28 and 75.76 to 86.60%, respectively. In addition, when the ITO films were deposited with the DC power of 400W and the Ar/O2 gas flow ratio of 30/2 sccm used in 5 wt% SnO2 target, its chromaticity (b*) and transmittance were about -2.98 to 14.22 and 74.29 to 88.52%, respectively.
        4,000원
        15.
        2009.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The objective of this study was to investigate the relationship between addiction to online games and carpal tunnel syndrome (CTS) in college students. A total of 377 (205 male and 172 female) college students completed an online game addiction scale, a Symptom Severity Scale (SSS), and a Function Status Scale (FSS) for CTS. It was found that five (1.3%) students were diagnosed with an online game addiction, 74 (19.6%) students were diagnosed with a pre-addiction to online games, and 298 (79.0%) students were diagnosed as being average users. The pre-addiction group had significantly higher scores on the SSS than did the average user group (p<.05). The average user group scored significantly lower than did the online game addiction group (p<.05). Symptoms of wrist pain and hand numbness in the daytime were common in the addiction group. There were statistically significant but poor positive relationships between the online game addiction scale and the SSS (r=.312, p<.01), and between the online game addiction scale and the FSS (r=.149, p<.01). The information about online game addiction and CTS identified in this study could contribute to the prevention of online game addiction and CTS in college students.
        4,000원
        17.
        2023.06 KCI 등재 서비스 종료(열람 제한)
        국내 포항 소재 R사의 구룡포산 천연 제올라이트의 물리·화학적 특성을 규명하기 위해 X-선 회절 분석, X-선 형광 분석, 열 시차·열 중량 분석, 양이온 교환능 분석 및 세슘(Cs), 스트론튬(Sr) 흡착 실험을 수행하였다. X- 선 회절 분석 결과 모데나이트, 휼란다이트, 클라이놉티로라이트 및 일라이트와 같은 광물이 함유되어 있으며, X- 선 형광 분석 결과 SiO2, Al2O3, CaO, K2O, MgO, Fe2O3 및 Na2O 원소가 함유되어 있었다. 양이온 교환능은 148.6 meq/100 g이었으며 열시차 및 열중량 분석 결과 600℃까지 열적으로 안정성이 우수한 것을 확인하였다. 시 간에 따른 흡착 평형 실험 결과 세슘(Cs)의 경우 30분이내 스트론튬(Sr)의 경우 8시간이내에 평형에 도달하였으며 세슘(Cs) 및 스트론튬(Sr)의 흡착률은 각각 80% 및 18%를 보이고 있었다. 단일 성분 등온 흡착 실험 결과 Langmuir model에 부합하였으며 세슘(Cs) 최대 흡착량은 131.5 mg/g으로 높게 나타났으며 반면 스트론튬(Sr) 최 대 흡착량은 29.5 mg/g로 낮은 흡착량을 나타내었다. 본 연구에 사용된 천연 제올라이트의 경우 클라이놉티로라 이트, 휼란다이트 및 모데나이트와 같은 8-ring을 포함하는 광물의 함량이 높아 세슘(Cs)에 대한 높은 선택성을 보 여주고 있다.
        18.
        2022.12 KCI 등재 서비스 종료(열람 제한)
        Tl+ 이온으로 교환된 제올라이트 A (|Tl12|[Si12Al12O48]-LTA, Tl12-A) 단결정을 진공 탈수시킨 후, 623 K 에서 72시간 동안 ZrI4 (g, 6.0 × 103 Pa) 와 반응시켜, Zr,I,Tl-A (|Zr0.25I1.5Tl12|[Si12Al12O48]-LTA)를 제조하였다. 제조된 단결정의 구조는 294 K에서 단결정 X-선 회절 기술을 이용하여 Pm3m (a = 12.337(2) Å) 입방 공간군에 속함을 확인 하였고, Fo> 4σ(Fo)를 사용하여 최종 오차 인자를 R1/wR2= 0.055/0.189로 정밀화 하였다. 이 구 조에서 Tl+ 이온은 6-ring 맞은편의 3-fold 축상의 서로 다른 3개의 결정학적 위치에서 단위세포당 7.5개가 발 견되었고, 모든 8-ring 근처(단위세포당 3개)에서 3개의 결정학적 위치로 채워졌다. 그리고 단위세포당 1.5개의 Tl+ 이온은 ZrI4(g)와 반응 후 sodalite cavity 안에서 3-fold 축상을 벗어난 자리에서 골격산소 O2 및 O3와 결 합하면서 발견되었다. Zr4+ 이온은 6개의 I- 이온과 함께 8면체의 ZrI6 2- 형태로 large cavity 정중앙에 존재하 였고, 이들은 8-ring 및 6-ring 근처에 존재하고 있던 Tl+ 양이온과 3차원적으로 연결하면서 ZrI6Tl11 9+ cationic cluster을 형성하였다. 이러한 cationic cluster은 Zr,I,Tl-A의 large cavity 중에서 약 25%에만 존재하였다.
        19.
        2022.06 KCI 등재 서비스 종료(열람 제한)
        몽골(6종), 미국(1종), 한국(9종)지역에서 채취한 총 16종의 천연 제올라이트를 X-선 회절 분석, X-선 형광 분석, 열 시차, 열 중량 분석 및 양이온 교환능 분석을 통해 특성분석을 수행하였다. 16종의 시료 모두 두 종류 이상의 광물상이 공존하는 혼합광 형태이며, 주로 클라이놉틸로라이트, 휼란다이트, 모데나이트 및 차 바자이트와 같은 광물의 조합으로 이루어져 있으며, 일부 시료에서는 운모 점토광물인 일라이트와 석영과 같은 광물이 불순물로 함유되어 있었다. X-선 형광 분석 결과 16종의 천연 제올라이트는 SiO2, Al2O3, K2O, CaO, Na2O, MgO 및 Fe2O3 산화물이 함유되어 있었다. 미국 천연 제올라이트인 U-1 시료가 223.3 meq/100 g으로 양이온 교환능이 가장 높게 나타났으며 몽골 천연 제올라이트에서는 M-6 시료가, 한국 천연 제올라이트에서는 K-1 시료가 각각 166.6 meq/100 g으로 가장 높게 나타났다. 열시차 및 열중량 분석 결과 16종의 시료 모두 600℃까지 열적으로 안정성이 우수한 것을 확인 하였다.
        20.
        2022.03 KCI 등재 서비스 종료(열람 제한)
        이온교환 용액내 Na+ 이온의 몰농도 증가에 따른 zeolite A의 Sr2+ 이온교환 특성을 연구하기 위하여, Sr2+ 및 Na+ 이온으로 교환된 4개의 zeolite A 단결정을 혼합 이온교환 용액을 이용하여 회분법으로 준비하였 다. 이들 이온교환용액의 전체 몰농도는 0.05M이며, Sr(NO3)2:NaNO3 몰비는 각각 1:1(crystal 1), 1:100(crystal 2), 1:250(crystal 3), and 1:500(crystal 4) 이다. 이들 단결정은 623 K와 1×10-4 Pa의 진공하에서 2 일간 탈수 시 켰다. 이들의 구조는 단결정 싱크로트론 X-선 회절법으로 입방공간군 Pm3-m을 사용하여 해석하였으며 crystals 1, 2, 3 및 4의 최종 오차 인자를 각각 0.047/0.146, 0.048/0.142, 0.036/0.128, and 0.040/0.156로 정밀화하였다. Crystal 1과 2에서는 6개의 Sr2+ 이온이 결정학적으로 서로 다른 3개의 위치에서 발견되었다. Crystal 3에서는 1 개의 Sr2+ 이온과 10개의 Na+ 이온이 large cavity와 sodalite 내부에서 발견 되었다. Crystal 4 에서는 단지 12 개의 Na+ 이온만이 3개의 서로 다른 결정학적 자리에 점유하고 있었다. Sr2+ 이온의 이온교환율은 초기 Na+ 이온의 농도가 증가하고 Sr2+ 이온의 농도가 감소함에 따라 100에서 16.7 및 0%로 급격하게 감소 하였다. 또한, Sr2+ 이온 교환률이 감소 함에 따라 제올라이트 골격의 단위 격자 상수 값이 갑소 하였다.
        1 2