A method using liquid chromatography-tandem mass spectrometry (LC-MS/MS) was developed for neonicotinoid pesticide analysis in agricultural products. Four compounds (imidacloprid, clothianidin, acetamiprid, thiacloprid) were extracted with acetonitrile from agricultural products and cleaned up by NH2 solid-phase extraction procedure, and eluted with 0.1% formic acid in methanol/dichloromethane (5/95, v/v). The limit of detection and quantification were 0.0001-0.0005 mg/kg and 0.001 mg/kg, respectively. The mean recoveries of neonicotinoid pesticide from agricultural products were in the range of 90.7-100.9% and 94.4-99.8%, as spiked at 0.2 mg/kg and 0.02 mg/kg, respectively. This validation satisfied the national criteria for pesticide analytical methods. In summary, The present method is fast, precise and sensitive enough for the Positive List System (PLS), and we conclude that the method is also suitable for neonicotinoid pesticide determination in a wide range of agricultural products.