Korea's facility horticultural heating costs account for a high proportion. Therefore, it is the most important factor to consider in greenhouse construction. It is important to assess the heating load of greenhouses. But there is not much data from the weather station. This study determined the heating load for each segmented area using the spatial correction method. The heating degeneration calculated from standard weather data (AHDH and BHDH) and total weather data (CHDH and DHDH) is consistent. However, there was a big difference between AHDH and DHDH. Therefore, the updated heating load data for each region is needed. Each of the four types of set temperatures (8℃, 12℃, 16℃, 20℃) was provided, and the heating temperature setpoint (℃) for each region of 168 cities and counties was presented. As a result of the analysis, the reliability of about 99% was confirmed in most of the regions suggested in this study. By using the calculated heating load for each region, it is possible to predict and utilize energy consumption and management costs.