논문 상세보기

Simulating Evaluation for Efficient Design and Manufacture of Spent Nuclear Fuel Burnup Detector Using MCNP

  • 언어ENG
  • URLhttps://db.koreascholar.com/Article/Detail/431120
모든 회원에게 무료로 제공됩니다.
한국방사성폐기물학회 학술논문요약집 (Abstracts of Proceedings of the Korean Radioactive Wasts Society)
한국방사성폐기물학회 (Korean Radioactive Waste Society)
초록

For efficient design and manufacture of PWR spent fuel burnup detector, data simulated with various condition of spent fuel in the NPP storage pool is required. In this paper, to derive performance requirements of spent fuel burnup detector for neutron flux and dose rates were evaluated at various distances from CE16 and WH17 types of fuel, representatively. The evaluation was performed by the following steps. First, the specifications of the spent fuel, such as enrichment, burnup, cooling time, and fuel type, were analyzed to find the conditions that emit maximum radioactivity. Second, gamma and neutron source terms of spent fuel were analyzed. The gamma source terms by actinides and fission products and neutron source terms by spontaneous and (α, n) reactions were calculated by SCALE6 ORIGAMI module. Third, simulation input data and model were applied to the evaluation. The material composition and dose conversion factor were referred as PNNL-15870 and ICRP-74 data, respectively and dose rates were displayed with the MCNP output data. It was assumed that there was only one fuel modeled by MCNP 6.2 code in pool. The evaluation positions for each distance were selected as 5 cm, 10 cm, 25 cm, 50 cm, and 1 m apart from the side of fuel, respectively. Fourth, neutron flux and dose rates were evaluated at distance from each fuel type by MCNP 6.2 code. For WH 17 types with a 50 GWd/MTU burnup from 5 cm distance close to fuel, the maximum neutron flux, gamma dose rates and neutron dose rates are evaluated as 1.01×105 neutrons/sec, 1.41×105 mSv/hr and 1.61×101 mSv/hr, respectively. The flux and dose rate of WH type were evaluated to be larger than those of CE type by difference in number of fuel rods. The relative error for result was less than 3~7% on average secured the reliability. It is expected that the simulated data in this paper could contribute to accumulate the basic data required to derive performance requirements of spent fuel burnup detector.

저자
  • Young Hwan Choi(KONES Corp.) Corresponding author
  • Yun Sik Kim(KONES Corp.)
  • Moonoh Kim(KONES Corp.)