This study proposes a steel plate retrofit method and a polyurea method to improve the structural stability and usability of a factory floor slab with a thickness of 120mm. To assess vibration changes, vibrations were measured before and after retrofit. A numerical analysis model was also developed to evaluate improvements in structural safety and usability. The natural frequency increased from 11.4Hz to 17Hz through steel plate reinforcement, confirming an increase in slab stiffness. The damping ratio increased from 2.3% to 3.2% with polyurea reinforcement, indicating improved vibration reduction. Additionally, numerical analysis modeling showed that the natural frequency increased from 13.9Hz to 16.2Hz due to the steel plate reinforcement, enhancing the dynamic characteristics of the floor slab and confirming the reliability of the analysis model.