검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 48

        41.
        2010.04 KCI 등재 서비스 종료(열람 제한)
        The pressure drop through pulse air jet-type bag filter is one of the most important factors on the operating cost of bagfilter houses. In this study, the pilot-scale pulse air jet-type bag filter with about 6 ㎡ filtration area was designed and tested for investigating the effects of the four operating conditions on the total pressure drop, using the coke dust collected from a steel mill factory. When the face velocity is higher than 2 m/min, it is not applicable to on-spot due to the increase of power expenses resulting from a high-pressure drop, and thus, 1.5 m/min is considered to be reasonable. The regression analysis results show that the degree of effects of independent parameters is a order of face velocity > concentration > time > pressure. The results of SPSS answer tree analysis also reveal that the operation time affects the pressure drop greatly in case of 1 m/min of face velocity, while the inlet concentration affects the pressure drop in case of face velocity more than 1.5 m/min.
        42.
        2008.07 KCI 등재 서비스 종료(열람 제한)
        This study was carried out to evaluate the characteristics of atmospheric concentrations of volatile organic compounds(VOCs) and aldehydes for near a large shipyard. Most of the painting work in marine coating is performed indoor and outdoor. Most of the VOCs are emitted to the atmosphere as the paint is applied and cures. The massive scale of a ship makes it difficult to capture the emissions from outdoor painting. The VOCs are an important health and contributors to photochemical smog. The VOCs and aldehydes samples were collected using adsorbent tube and 2,4-DNPH cartridge, and were determined by an automatic thermal desorption coupled with GC/MS and HPLC-UV analysis, respectively. A total of 16 aromatic VOCs and 12 aldehydes of environmental concern were determined. At indoor coating facilities, the most abundant compound among 16 target VOCs appeared to be m,p-xylene, being followed by o-xylene. But most of the aldehydes were extremely lower concentrations. The atmospheric concentration of VOCs, m,p-xylene concentrations were the highest and the mean value were outdoor workshop 11.323 ppb, residental area 5.134 ppb, and green area 2.137 ppb, respectively. However, the most aldehydes were extremely lower concentrations such as formaldehyde, acetaldehyde and non-detection such as iso-valeraldehyde, n-valeraldehyde and o-tolualdehyde.
        43.
        2005.08 KCI 등재 서비스 종료(열람 제한)
        Scanning electron microscopy / energy dispersive X-ray analyzer(SEM/EDX) has played an important role for evaluation the source of atmospheric particle because it is a powerful tool for characterizing individual particles. The SEM/EDX system provides various physical parameters like optical diameter, as well as chemical information for a particle-by-particle basis. The purpose of the study was to classify individual particle emitted from the point sources based on clustering analysis and physico-chemical analysis by SEM/EDX. The total of 490 individual particle were analyzed at 8 point sources including coal-fired power plant, incinerator, B-C oil boiler, and metal manufacturing industry. The main components were Si and Al in the coal-fired power plant, Cl and Na in the domestic waste Incinerator, S in the B-C oil boiler and S and Fe in the metal manufactory industry, respectively.
        45.
        2004.03 KCI 등재 서비스 종료(열람 제한)
        The change of pressure drop according to the change in the inlet concentration, pulse interval, and injection distance of pulse air jet type bag filters, and the effect of venturi installation are as follows. The pressure drop with the range of 30 to 50mmH2O varies according to the injection distance with 30, 50, 70, 90sec and the inlet concentration of venture built-in fabric filters. For the lower concentration of 0.5g/m3 and 1g/m3, the pressure drop(ΔP) was stable 60 to 90minutes after operation. For the higher concentration of 3g/m3, as ΔP continues to go up, pulse interval should be set shorter than 30 seconds. The pressure drop with the injection distance of 110mm, when inlet dust concentration is 0.5g/m3 or 1g/m3, is 1.3 to 2 lower than with the injection distance of 50, 160, and 220mm, which means that the inflow amount of the secondary air by the instant acceleration is large. The injection distance of 2g/m3 and 3g/m3 has the similar pressure distribution. The higher inlet concentration is, the more important pulse interval is than injection distance. The pressure drop has proved to be larger when inlet concentration is lower and injection distance closer, on condition that the venturi is installed. The change in the pressure drop was smallest when injection distance was 50mm, followed by 220mm, 160mm, and 110mm.
        46.
        2002.07 KCI 등재 서비스 종료(열람 제한)
        UV photolysis process is little known in parts of air pollution treatment, so there are not many applications in field. Therefore we have to do more experiment and study application possibility for treatment of VOCs(Volatile organic compounds). To solve these problems, we have been studying for simultaneous application of this technology. It has shown that concentration of TCE and B.T.X., diameter of reactor and wavelength of lamp have effected on decomposition efficiency. Analysis of TCE and B.T.X. concentration was carried out by GC-FID. A cylinderical reactor consisting of a quartz tube and a centrally located lamp(ψ25mm) was used. The length and diameter of reactor were 1800mm, 75mm. It has shown that the generated ozone concentration goes up 250ppm when using 64watt ozone lamp. When using Photolysis process only, the rates of fractional conversion of each material are TCE 79%, Benzene 65%, Toluene 68%, Xylene 76%. This phenomenon can be rationalized in terms of the different bond energy that indicates how easily VOCs species can be decomposed.
        47.
        2002.06 KCI 등재 서비스 종료(열람 제한)
        The purpose of this study was to investigate spatial distributions of total deposition. A total number 79 samples were collected at 17 sampling sites from September 1999 to January 2000. Total (=wet+dry) atmospheric depositions were collected by filtered deposition sampler at sampling site (the Western Part of Kyongsangnam Province). In addition, the deposition of soluble and insoluble fraction was also investigated to find a suitable simplified collection method for a long-term monitoring of total deposition. The total depositions were measured soluble amount(mm/month), insoluble amount(kg/km2/month), pH, conductivity(E.C.) and eight ionic components. The spatial distribution of deposition flux was to estimated by using a kringing analysis. The 17 sites mean fluxes of water soluble ionic components; SO42-, Cl-, NO3-, Na+, NH4+, K+, Mg2+, Ca2+ were 100.7~315.6kg/km2/month, 30.1~234.3kg/km2/month, 64.4~139.4kg/km2/month, 7.5~68.3kg/km2/month, 10.7~48.7kg/km2/month, 5.6~27.9kg/km2/month, 4.5~17.5kg/km2/month, 27.6~81.7kg/km2/month, respectively.
        48.
        1998.08 KCI 등재 서비스 종료(열람 제한)
        This study has been carried out to investigate Electrostatic Precipitator`s(ESP) performance enhancement and removal efficiency of fine particle according to (NH_4)_2SO_4 injection rate. The following conclusions are derived from the these test results : 1)For plant condition cases, according to the variation of concentration agent [(NH_4)_2SO_4] - 10ppm, 20ppm, 30ppm, 40ppm - ESP`s collection efficiency was increased to 97.74%, 98.95%, 99.04%, 99.47%, when inlet dust loading was 2g/㎥. And when inlet dust loading was 3g/㎥, that was increased to 98.19%, 99.16%, 99.23%, 99.58%. 2)It is seen from this experiments that the increasing 30ppm concentration of (NH_4)_2SO_4 increase the collection efficiency and fine particle emission control.
        1 2 3