This study was carried out to determine the effect of biji addition on the quality of extruded isolated soy protein (ISP). ISP-based biji addition (0, 20, 40 and 60%) was extruded at die temperatures 140oC and 150oC and a screw speed of 250 rpm. The moisture contents were adjusted to 35% and 45%. As the content of biji increased from 0% to 60%, springiness, cohesiveness, and cutting strength of the extruded ISP were significantly decreased. When the die temperature increased from 140oC to 150oC and the water content increased from 35% to 45%, the nitrogen solubility index, cutting strength and integrity index decreased. When the biji addition was increased at a barrel temperature of 140oC and a moisture content of 45%, the integrity index of the ISP texture decreased. With an increase in the addition of biji to ISP, rough surface and irregular fiber structure were observed, but regular microfiber structure was not observed.
This study aims to investigate the physicochemical properties of extruded Biji. As the extrusion process variables, the barrel temperature and the moisture content were adjusted at barrel temperatures of 120, 140, and 160°C and 35, 45% respectively. L-value (lightness) increased as the moisture content and barrel temperature increased from 35% to 45% and 120°C to 160°C. In contrast, decreasing a-value and b-value resulted in increasing moisture content and barrel temperature. Total sugar, DPPH (1,1-diphenyl-2-picrylhydrazyl) radical-scavenging activity, ABTS (2,2'-azino-bis-(3-ethylbenzothiazoline-6-sulfonic acid)) radical scavenging activity, and total phenolic compound were increased by the extrusion process. The water solubility index (WSI) and dietary fiber of the extruded biji decreased to 3.9% and 592.6 mg/g compared to the non-extruded biji of 12.3% and 592.6 mg/g. According to the result of this study, the extruded biji could be used in various kinds of food processing, and future study is needed to find the optimum condition of the extrusion.
구강 및 두경부 암의 방사선치료 시 치료 범위에 피부를 포함하는 경우가 많으며 이때 볼루스의 사용이 빈번해진다. 특히 턱 부분의 요철로 인하여 환자의 적용 시 선량 불확실성을 제공한다. 본 연구에서는 3D Printing을 이용하여 Gel 볼루스와 Poly lactic acid(PLA), Silicon을 적용한 환자 맞춤형 볼루스를 제작하여 물성 특성을 확인하고, 제작된 볼루스와 치료계획의 불일치성을 확인하며, 실제 방사선 선량 전달시 발생하는 선량불확실성을 측정하였다. 그 결과 일반적인 요철 부위에는 PLA 재질의 볼루스가 안정적이며, 요철이 심하거나 환자의 체형이 자주 바뀔 수 있는 환자의 경우 Silicon 재질의 볼루스가 유용할 것으로 사료된다.
Compton suppression 장치는 Compton 산란 반응을 이용하여, 스펙트럼의 Compton continuum 부분을 억제함으로써 Compton continuum 영역 내에서의 감마선 피크들의 분석을 보다 명확하게 할 수 있게 해주는 장치이다. 표층토양 시료에서 검출된 인공 방사능인 137Cs과 자연 방사능인 40K핵종의 방사능 농도 값들에 대한 방사능 계수치가 백그라운드를 상회하는 측정값이 발생되거나, 불필요한 방해피크나 비해석 대상 피크에 대하여 검출된 표준선원의 방사능 농도 값들의 실측치에 대한 background를 비억제 스펙트럼(Compton Unsuppression)과 억제 스펙트럼(Compton suppression)을 적용시켜 측정 에너지에 대한 교정을 알고자 점선원인 137Cs을 거리별에 따라 측정하여, 몬테칼로 시뮬레이션과 비교 분석함으로서 효율적인 검출 능력을 얻고자 함이며, Compton 억제 인자를 보면 거리가 멀어짐에 따라 CSF 값이 클수록 더 많은 Compton suppression가 이루어졌음을 알 수 있고, 137Cs을 이용한 컴프턴 비억제 모드와 억제모드로 측정된 스펙트럼에서 컴프턴 연속에 의한 백그라운드가 감소함을 알 수 있었다.