The aim of this study was to improve the chemical stability of cycloserine containing organic and inorganic compounds. Composite particles were manufactured with a 1:1 weight ratio of organic/inorganic compounds and cycloserine. The influence of organic/inorganic compounds on the stability of cycloserine was investigated under accelerated stress conditions at 60°C/75% RH for 24 hours. In addition, the properties of the composite particles were evaluated using differential scanning calorimetry (DSC), scanning electron microscopy (SEM), and the dissolution of the drug was assessed by preparing it as a hard capsule. Among the organic and inorganic compounds investigated, calcium hydroxide most improved the stability of cycloserine under accelerated stress conditions (53.3 ± 2.2% vs 1.7 ± 0.2%). DSC results confirmed the compatibility between calcium hydroxide and the cycloserine, and SEM results confirmed that it was evenly distributed around the cycloserine. Calcium hydroxide also showed more than 90% cycloserine dissolution within 15 minutes. Therefore, the calcium hydroxide and cycloserine composite particles may be candidates for cycloserine oral pharmaceuticals with enhanced drug stability.
In zinc-air batteries, the gel polymer electrolyte (GPE) is an important factor for improving performance. The rigid physical properties of polyvinyl alcohol reduce ionic conductivity, which degrades the performance of the batteries. Zinc acetate is an effective additive that can increase ionic conductivity by weakening the bonding structure of polyvinyl alcohol. In this study, polymer electrolytes were prepared by mixing polyvinyl alcohol and zinc acetate dihydride. The material properties of the prepared polymer electrolytes were analyzed by Fourier-transform infrared spectroscopy (FT-IR), scanning electron microscopy (SEM), X-ray diffraction (XRD), and thermogravimetric analysis (TGA). Also, Electrochemical impedance spectroscopy was used to calculate ionic conductivity. The electrolyte resistances of GPE, 0.2 GPE, 0.4 GPE, and 0.6 GPE were 0.394, 0.338, 0.290, and 0.213 Ω, respectively. In addition, 0.6 GPE delivered 0.023 S/cm high ionic conductivity. Among all of the polymer electrolytes tested, 0.6 GPE showed enhanced cycle life performance and the highest specific discharge capacity of 11.73 mAh/cm2 at 10 mA. These results verified that 0.6 GPE improves the performance of zinc-air batteries.
저자들은 절제 불가능한 국소진행형 췌장암 환자가 동시 적 항암화학방사선요법 및 gemcitabine 유지 항암화학요법을 받은 후 장기간 동안 완전 관해를 유지하고 있는 증례를 보고하는 바이다. 이 증례를 통해 다른 절제 불가능한 국소 진행형 췌장암 환자들에게도 동시적 항암화학방사선요법 및 gemcitabine 유지 항암화학요법 치료를 시도해 볼 수 있을 것이다.
기후 변화가 가속화되어 국내에서는 국지성 호우가 증가하는 추세이며, 이에 대해 도심지역 토지의 불투수층이 증가하여 도로 유출수, Combined Sewer Overflows(이하 CSOs라고 한다.) 등 도심에서의 비점오염원에 의하여 하천 수중생물의 폐사, 부영양화, 대장균 및 병원성 미생물의 증가, 중금속 오염 등의 방류 수계에 타격을 줄 수 있기 때문에 이에 따른 환경오염 문제가 대두되고 있다. 그 중에서도 CSOs는 합류식 하수도 시스템에서 강우 시에 처리시설을 거치지 않고 하천이나 해안 등의 수계로 직접 방류되는 경우를 의미하며, 해당 오염 부하량은 강우의 지속시간 및 강우량에 큰 영향을 받는다. 이 때 합류식 하수관로에서는 관로 내부의 퇴적물이 강우 초기에 유출되는 초기세척효과(first flush effect)에 의해 강우 초기에 오염부하량이 높은 값으로 유출된다. 이런 CSOs에 대하여 현재 국내에는 3Q로 차집한 용량에 대하여 2Q의 월류수를 스크리닝 및 완충저류로 이루어진 간이처리만을 통하여 수계로 배출되고 있는 실정이다. 이러한 CSOs의 주된 오염물질은 입자성 물질이 가장 큰 비율을 차지한다. 환경부에서 제시한 임의의 도시지역 하수 평균 SS는 60 mg/L의 값을 나타내는데 강우 초기의 CSOs의 SS는 1,936 mg/L의 값으로 고농도의 값을 나타낸다. 이러한 입자성 물질을 제거해 줌으로써 입자성 물질에 영향을 받는 다른 항목에 대해서도 그 농도를 낮출 수 있다. 이에 본 연구에서는 CSOs의 입자성 물질을 제거하기 위한 공정으로 여과(filtration)방법을 선정하였으며, 여과용 담체로는 폐유리를 발포시켜 제조한 여재를 사용하였다. 여과속도 및 여과층 구성에 따른 SS제거효율 및 폐색된 여재의 효율을 복구시키기 위한 역세척 조건에 따른 역세척 효율에 대해 알아보고자 하였다.