검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 4

        1.
        2010.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The objectives of this study were to investigate the microbial contamination levels on food service in university and to provide the information of microbial contamination to improve food safety. A total of 288 samples were collected during summer and winter season between 2006 and 2008 from 4 food services located in the university in Western Gyeongnam and were used to detect sanitary indicator bacteria [aerobic plate count (APC), coliform,and Escherichia coli] and pathogenic bacteria (Staphylococcus aureus, Salmonella spp.). As a result, APC and coliform for hand and kitchen utensils which are used often by the employee were detected at high levels of 1.1~5.5and 1.3~5.3 log CFU/(100 cm2, hand), respectively. The contamination levels of APC and coliform in cooked foods and drinking water were 0.8~6.4 and 1.3~5.0 log CFU/(g, mL), respectively. Especially, the cooked foods showed the highest contamination for APC (2.1~6.4 log CFU/g) and coliform (1.0~5.0 log CFU/g). We think the reason that the cooked foods may be contaminated with APC and coliform on cooking process by using employee’s hand and kitchen utensils. Moreover, S. aureus for hand and kitchen utensils was detected at levels of 2.8~3.0 and 2.0~2.3 log CFU/(g,hand), but Salmonella spp. was not detected. According to the above results, contamination levels of the samples were mostly decreased irrespective of summer and winter season. The results obtained indicated that it is necessary to periodic monitoring for microorganism contamination and education about personal and environmental hygiene to employee for ensuring food safety of food service in university.
        4,000원
        3.
        2015.10 서비스 종료(열람 제한)
        In this paper, the tensile capacity of the grout-filled head splice sleeve experienced repeated loads was evaluated. From the tensile test of the sleeves, it was found that all the sleeves had enough tensile strength showing the tensile failure of the steel bars.
        4.
        2014.10 서비스 종료(열람 제한)
        This paper presents a design process of columns in precast concrete frame building structure constructed by using hollowed precast concrete (HPC) column. An example PC frame building was designed and the structural safety of HPC columns was checked as a form for during slab construction and a composite column for design load after construction based on the previous research.