검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 8

        1.
        2021.12 KCI 등재 서비스 종료(열람 제한)
        The role of the distribution basin role is to apportion incoming raw water to the primary sedimentation basin as part of the water treatment process. The purpose of this study was to calculate the amount of water in the distribution basin using computational fluid dynamics (CFD) analysis and to find a way to improve any non-uniformity. We used the Taguchi method and the minitab tool as optimization methods. The results of the CFD calculation showed that the distribution flow had a deviation of 5% at the minimum inflow, 10% at the average inflow, and 22% at the maximum inflow. At maximum flow, the appropriate heights of the 7 weirs(C, D, A, B, E, F, G) were 40 mm, 20 mm, 20 mm, 0, 0, 0, and 20 mm, respectively, according to the Taguchi optimization tool. Here, the maximum deviation of the distribution amount was 9% and the standard deviation was 23.7. The appropriate heights of the 7 weirs, according to the Minitab tool, were 40 mm, 20 mm, 20 mm, 0, 0, 0, and 20 mm, respectively, for weirs C, D, A, B, E, F, and G. Therefore, the maximum deviation of the distribution amount was 8% and the standard deviation was 17.1, which was slightly improved compared to the Taguchi method.
        2.
        2011.08 KCI 등재 서비스 종료(열람 제한)
        The covered stream of cities are considered an odor source. Also, the public do not want a wastewater treatment plant(WWTP) near their properties due to the emission of odor emanating from such sources, although they play an important role in urban development. The purpose of this study is to analyze the pattern distribution of the odorous compounds from the Nambu WWTP and Youngho stream in Busan. odor sampled four times were analyzed by instrumental analysis method and indirect olfactory method. The kinds of offensive odorous compounds examined are acetaldehyde, propion aldehyde, hydrogen sulfide, methyl mercaptan, dimethyl sulfide and ammonia. Also, Concentration of air pollutants has been calculated by ISCST3 models. At the result of this study, The Nambu WWTP releases sulfur compounds. And the major odorous were hydrogen sulfide (1,475 ppb) and acetaldehyde (95 ppb) at Youngho stream. The stink which residents feel will point out the Nambu WWTP mainly if the odor is removed with the improvement of a Youngho stream. Accordingly, we should pay more attention to appropriate components to processes in odor reducing plan at Nambu WWTP.
        3.
        2010.03 KCI 등재 서비스 종료(열람 제한)
        To acquire preliminary data for the control of total nitrogen (TN) in S sewage treatment plant, which processes merging food waste and sewage, the effect of reject water on the total nitrogen in the effluent was examined in this study. Water quality data for the plant during the winter period were applied to calculate the mass balance. It was calculated that at least more than 231 kg/d TN should be removed to control the TN concentration in the effluent. Assuming 18 ppm as the goal TN concentration in the effluent, about 941 kg/d TN should be removed from this plant. Approximately 10% more TN should be removed than at present to achieve this result. It was observed that dewatering the filtrate had a considerably greater effect on the total nitrogen in the effluent than the reject waters. The dewatered filtrate contained 1,399kg/d TN. The contribution of the dewatered filtrate to the TN concentration in the effluent was 0.183, which was 7 to 23 times greater than the other reject waters. In addition, the amount of total nitrogen from the reject water, with the exception of the dewatering filtrate, was lower than the amount of TN that should be removed from S sewage treatment plant. Therefore, it was concluded that one of the most effective methods for controlling the TN concentration in effluent was the removal of the TN contained in the dewatering filtrate.
        8.
        1999.02 KCI 등재 서비스 종료(열람 제한)
        수영하수처리장 방류수의 해중방류법과 3차 처리 시설 설치의 비용분석을 한 결과는 다음과 같다. 1) 해안에서 4km 거리와 관경을 2m의 해중방류법을 이용한 수용만의 수질을 개선시키는데 소요되는 해중방류관 건설비용은 383억 원이 소요되는 것으로 산출되었다. 2) 수영하수처리장의 유출수를 해중방류관을 통해서 방류할 경우 방류수심을 32m, Diffuser의 길이를 200m로 할 경우의 초기희석배율은 유속에 따라서 56.4∼399.2으로 계산되었다. 3) 질소를 제거하기 위한 순환법의 경우의 20년 동안의 총 비용은 1,364억 원, 인을 제거하기 위한 응집제 첨가 활성슬러지법은 1,010억 원, 해중방류법은 383억 원으로 해중방류법이 3차 처리시설을 설치하는 비용보다 약 2.6∼3.5배 비용을 적게 소요하는 것으로 산출되었다. 4) 해중방류법을 이용할 경우의 수영만의 수질영향을 예측하기 위해서 물질순환모델을 이용하여 예측한 결과 수영만의 수질이 COD, 용존무기질소(DIN)와 용존무기인(DIP)의 전 항목에서 해역환경 II등급을 만족하는 것으로 예측되었다.