검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 6

        1.
        2016.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The present study analyzes the flexure behavior of the circular CFT member through experiment and numerical analysis. Through comparison between experimental and numerical results, whether or not the member was a full composite have little effect on the behavior. There circular CFT’s flexure behavior when considering pure moment is almost similar regardless of the interface characteristics between the steel and concrete. This is because there is no difference in the neutral axis of the full-composite and non-composite circular CFT member.
        4,000원
        2.
        2016.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Two types of connection between the abutment and CFT pile were proposed for the sub-structure of the integral abutment bridge. One was a bolt connection (Type-A) and the other was a hook connection (Type-B). To analyze the performance of connection Type-A and Type-B, a quasi-static experiment was carried out. According to experimental results, the destruction occurred at the connection point and so both type A and type B need to have a reinforced design as the link between the abutment and CFT pile. However, when the load resistance performance and energy dissipation capacity was analyzed, the performance of connection Type-B was superior to the performance of connection Type-A.
        4,000원
        3.
        2016.04 구독 인증기관 무료, 개인회원 유료
        In this study, a quasi-static experiment was conducted on the connection performance between the integral abutment bridge and CFT pile. Six experiment specimen were manufactured and were divided into type A and type B. Experiment specimens of Type A were connected with bolts and experiment specimens of Type B were connected with hooks. In the experiment results the connection performance of Type B showed excellent performance more than that of Type A.
        3,000원
        4.
        2015.04 구독 인증기관·개인회원 무료
        In this study, we study the behavior of CFT subjected to pure bending moment considering the interface character between the materials. We assume that the interface between the materials has 2 cases, one is full-composite the other is non-composite. Through the analysis of the FEM results, we find that CFT’s flexure behavior is unique compared to other composite structures. There is almost similar CFT’s flexure behavior in the pure moment regardless of interface character between steel and concrete. This is because there is no difference in the neutral axis of the full-composite and non-composite in the CFT scetion.
        6.
        2021.06 KCI 등재 서비스 종료(열람 제한)
        목적: 본 연구는 태권도선수의 실패공포, 지각된 케어링, 운동지속의도의 구조적 관계를 분석하여 기초자료의 축 적과 연구의 활용을 기대하고자 한다. 방법: 이를 위해 연구자는 수도권 및 광역시⋅도에 소재한 각 품새팀 중 20개 팀을 무작위로 선정하여 총 225명을 대상으로 표본을 추출하였고, 총 202부의 자료를 최종유효표본으로 사 용하였다. 본 연구의 가설을 검증하기 위해 Window SPSS Ver 22.0 프로그램을 이용하여 빈도분석, 탐색적 요인 분석, 신뢰도분석, 독립표본 t-검정과 일원배치 분산분석을 실시하였고, AMOS Ver 22.0 프로그램을 이용하여 확 인적 요인분석, 상관분석, 구조방정식모형(SEM) 분석을 실시하였다. 결과: 첫째, 태권도선수의 인구사회학적 특성 에 따라 일부 변수에서 유의한 차이가 나타났다. 둘째, 태권도선수의 실패공포는 지각된 케어링에 부분적으로 유 의한 영향을 미쳤다. 셋째, 태권도선수의 지각된 케어링은 운동지속의도에 유의한 영향을 미쳤다. 넷째, 태권도선 수의 실패공포는 운동지속의도에 부분적으로 유의한 영향을 미쳤다. 다섯째, 태권도선수의 실패공포와 운동지속의 도 간의 관계에서 지각된 케어링은 부분적으로 매개효과가 있는 것으로 나타났다. 결론: 이러한 연구결과를 통해 태권도선수가 시합 상황에서 느끼는 실패공포를 보다 이해하고, 올바른 지도의 필요성을 확인하였다.