검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 1

        1.
        2014.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study was performed to measure the concentration of odorous compounds and dilution ratio values at each part of the anaerobic digester process with composting facilities using swine manure and food waste. Complex odors, ammonia, volatile fatty acids and sulfur compounds were measured at each part of the process. Complex odors measured during swine manure storage, food waste storage and in the digested liquid tank, were 35,312 Odor Unit(OU), 39,086 OU and 17,733 OU, respectively. The odor contribution index was calculated by the concentration of odorous compounds during each process divided by the threshold limit. As a result, the major odorous compound that appeared during swine manure storage, food waste storage and in the digested liquid tank was hydrogen sulfide. On the other hand, the major odorous compound in the other processes was ammonia. The overall average concentrations of ammonia were highest in the digested liquid tank(337 ppm) and the separated liquid tank(131 ppm). Wastewater treatment process(10.9 ppm) and deodorization process(11.6 ppm) revealed the lowest concentration of ammonia. The overall average concentration of total volatile fatty acids(TVFAs) was 102.8 ppb during food waste storage and among the TVFAs, the main element was propionic acid(66.1 ppb). Sulfur compounds were only detected during swine manure storage, food waste storage and in the digested liquid tank. The dominant sulfur compound was hydrogen sulfide during swine manure storage(96.3 ppm) and methyl mercaptan during food waste storage(17.7 ppm) and dimethyl sulfide during food waste storage(34.5 ppm).
        4,000원