Hole carrier selective MoOx film is obtained by atomic layer deposition(ALD) using molybdenum hexacarbonyl[Mo(CO)6] as precursor and ozone(O3) oxidant. The growth rate is about 0.036 nm/cycle at 200 g/Nm of ozone concentration and the thickness of interfacial oxide is about 2 nm. The measured band gap and work function of the MoOx film grown by ALD are 3.25 eV and 8 eV, respectively. X-ray photoelectron spectroscopy(XPS) result shows that the Mo6+ state is dominant in the MoOx thin film. In the case of ALD-MoOx grown on Si wafer, the ozone concentration does not affect the passivation performance in the as-deposited state. But, the implied open-circuit voltage increases from 576 oC to 620 oC at 250 g/Nm after post-deposition annealing at 350 oC in a forming gas ambient. Instead of using a p-type amorphous silicon layer, high work function MoOx films as hole selective contact are applied for heterojunction silicon solar cells and the best efficiency yet recorded (21 %) is obtained.
Background: In the stroke patients with the characteristics of hemiplegic gait, turning direction of the affected and unaffected side influences turning time. Therefore, it is important to investigate the walking response to turning directions in stroke patients. Objects: This study aimed to measure the walking time while turning direction in hemiplegic patients depending on balance ability measured by Berg Balance Scale. Methods: A group of forty-five subjects with stroke (Berg Balance Scale score≥46 were twenty-eight, Berg Balance Scale score≤45 were seventeen) were enrolled in this study. Subjects were asked to perform the Timed Up and Go test. Testing indications included two directions for turning in each subject. These indications were for turning toward the affected and unaffected side in stroke patients. The duration of total analysis duration, sit to stand phase, stand to sit phase, mid-turning phase, and end turning phase were recorded. The obtained data were analyzed by using paired t-test and Wilcoxon signed rank test in the group that are below and above 45 points of Berg Balance Scale score. The significance level was set at ɑ=.05. Results: There were significant increase time in the analysis duration and end turning phase duration while subjects were turned the unaffected side in stroke patients that presented a Berg Balance Scale score≤45 (p<.05). However, the comparison between the affected side and the unaffected side in the stroke patients with Berg Balance Scale score≥46, revealed no significant differences of the measured parameters. Conclusion: This finding should be suggested in the specific definition of turning direction for evaluation with Timed Up and Go test in the Berg Balance Scale score≤45, and other intervention for hemiplegic patients need to be suggested the direction of turning during walking training program.
보일러 배기가스를 이용해 온실 내부의 CO2 농도를 높여 식물의 생장을 촉진하는 CO2 시비 시스템의 공급 최적화를 위한 연구를 진행하였다. 다기관의 유로를 사용하는 시비 시스템의 기하학적 변수에 따른 유량균일성 파악을 위해 전산유체역학 기법을 사용하였다. 먼저 PVC 형상을 수정하여, 처음 설비에서 출구유량이 적어 튜브 뒤쪽까지 CO2가 나오지 못했던 문제점을 해결하고 개선된 형상을 결정했다. 그 다음 실험값과 동일하게 맞추기 위하여 실험값과 해석값의 출구 속도를 비교하여 입구 압력을 결정하였다. 이때 여섯 개의 출구에서 나타나는 유량 비균일성은 출구에 Gasket을 부착하여 출구 면적 변화를 통해 유량을 조절할 수 있다고 보았다. 여섯 개의 출구 직경을 각각 변화시킨 3개의 Case 결과가 출구 면적을 모두 동일하게 두었을 때보다 편차가 최대 ±18%까지 감소되었다. 비닐 튜브 역시 뒤쪽까지 CO2가 전달되지 못하는 문제점을 해결하기 위하여 출구의 직경을 변화시켜가며 비교하였다. 각각의 출구 직경은 동일하게 하고 입구 면적 대비 출구 면적이 153.4%(D = 10mm), 97.8% (D = 8mm), 54.9%(D = 6mm)이 되도록 3개의 Case로 나누어 유량 균일성 향상 효과를 알아보았다. 그 결과 출구직경이 10mm일 때보다 6mm일 때, 유량 편차가 ±13% 정도 감소되었다. 따라서 출구 면적이 작아질수록 유량 균일성이 향상됨을 파악하였다. 앞서 결정된 최적 PVC 형상과, 비닐 튜브 조건을 조합하여 전체 형상을 해석한 경우 역시 모든 hole에서의 유량이 0.1g/s 이내의 차이를 보이며 높은 균일성을 나타냈다. 이와 같은 방법으로, 다기관의 유로를 이용하여 CO2를 분배시키는 다른 형태의 시비 시스템에서 역시 PVC 배관에서의 압력강하를 최소화시킨 뒤, PVC와 비닐 튜브의 출구 직경을 변화시키는 순서로 각 출구로의 유량을 균일하게 조정할 수 있을 것으로 판단된다.
본 연구에서는 수자원 계획 및 가뭄관리를 위해 비교적 넓은 지역에 활용할 수 있는 가뭄지표 산정을 위해 강우량, 일최고기온, 유출량, Palmer 지수 등의 다양한 계열의 자료를 이용하였다. 가뭄감시를 위해 가뭄단계를 가뭄주의보, 가뭄경보, 비상가뭄으로 구분하였으며, 각각 가뭄단계는 산정된 지수의 25%, 10%, 5%에 대한 비초과확률치로 정의하였다. 또한 가뭄지수들이 과거의 가뭄을 얼마나 잘 표현하고 있으며, 가뭄감시를 위한 가뭄지표로 활용할 수 있