        This study examined management problems about the current rural sewage treatment facilities where is outside of sewage treatment boundary in Chungnam province. It suggested that optimum plan based on this investigation as follows. Management cost of sewage treatment facilities considering the circuit operation person was charge of about 51.8% personnel expenditure, 31.0% electricity power cost, and 9.9% repairing expenses. So, the presumptive cost will be to ₩191/㎥․d for the facility capacity a year. Recently the core operation and management has converted to environment related section or consignment company but a work subjective section administers the facilities that is a 75 districts of total 161 business zone yet. It is desirable to conclude a commission contract with the company which is operate the facilities including circuit operation person for sewage treatment plants. And it recommend that one who has qualified or certificate requirement for the sewage treatment should be stationed at the related section because there are no experienced men in many treatment facilities. Rural sewage treatment facilities and small sewage treatment plant whose capacity is more than 500㎥/d ought to be controlled by collecting sewage tax involved the related special budget according to local government regulations and the charge would be to notify the actual usage. Also, it is necessary to introduce unmanned automatic operating system in order to reduce labor costs, advance progressive management, and operate integrated management of facilities.