검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 3

        1.
        2019.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        A survey on the indoor air quality of schools was conducted on a total of 10 schools in each location, such as industrial zones, roadside zones and clean zones of the Jeonbuk Province. Regardless of their location, 75% of the schools were not suitable to the environmental standard, and five schools were inadequate in both the first and the second half measurement results. Compared to the public facilities survey conducted by the Jeollabukdo Institute Health and Environment Research from 2008 to 2016, the concentration of CO2, total airborne bacteria (TAB), and PM10, with the exception of HCHO, was higher in school classrooms than in any other public facilities. The correlations between pollutants and test items demonstrated that total airborne bacteria (TAB) were significantly correlated with the degree of ventilation, and the PM10 was correlated with the cleaning status, respectively. Although the other test items of indoor air quality in the school were measured in the same way as the public facilities measurement methods, the PM10 is applied in accordance with the simplified method. In order to investigate the difference between the measurement methods, the results were compared at the same point at the same time. When comparing the concentrations of PM10, the gravimetric method, which is a public facilities measurement method, showed a significant difference from the light scattering method, which is a method of measuring PM10 in schools. By comparison, it was confirmed that the light scattering method was measured lower than the gravimetric method. The light scattering method is useful for confirming the change of the particulate matter, but it is considered difficult to judge the concentration of the particulate matter in the classroom by the instantaneous measurement because of the potential error caused by high humidity, etc. Secondary pollution ions were measured at 17.1% ~ 40.5% in the industrial zone schools, 7.4%~27.4% in the roadside zone schools and 8.1%~21.8% in the clean zone schools, The percentage of pollution ions were not clearly distinguished by location.
        4,200원
        2.
        2005.08 KCI 등재 서비스 종료(열람 제한)
        천문동 (Asparagus cochinchinesis (Lour.) Merr.)의 기내생장과 증식의 가능성을 검토하기 위하여 신초의 유기, 생장 및 발근에 적합한 배지, 식물생장조절제, 배양온도를 검정한 결과를 요약하면 다음과 같다. MS 기본배지에 3.0 mg/l BA 처리시 신초의 유기 및 생장이 가장 양호하였으며 MS 기본배지에 0.5 mg/l IBA 처리가 발근에 가장 효과적이었고 기내배양 온도는 23~25℃가 적합하였다.
        3.
        2001.06 KCI 등재 서비스 종료(열람 제한)
        한인진에 대한 항산화 효과와 항균 효과를 알아보기 위하여 추출용매별 고형분 함량을 측정하여 본 결과 물 추출물에서 18. 1%로 가장 많은 고형분을 얻을 수 있었으며 메탄올, 에탄을 추출물에서는 12. 8%, 12. 6%로 별 차이가 없었다. 항산화 효과를 알아보는 방법 중 DPPH 소거효과를 이용하여 측정하여 메탄올 추출물이 36.2μg/ml로 가장 효과 좋았지만, 대두유에 대한 한한인진 추출물의 항산화 효과를 60℃로 20일간 저장하면서 과산화물가(POV)를 측정하여 대두유를 기질로 한 저장시험 에서 1,000ppm 농도의 물추출물과 메탄올 추출물이 저장 기간이 20일 되었을 때 46.8(meq/kg, 50.8(meq/kg)의 과산화물가를 나타내 대조구의 과산화물가 79.1 (meq/kg)에 비해 낮았다. 식품의 부패균이나 식중독의 원인균으로 알려진 세균 4종을 대상으로한 항균실험에서는 추출 용매에 따른 항균력은 에탄올 추출물이 가장 좋았으며 세균에 대한 항균력으로는 Vibrio parahaemolyticus에 대해 가장 좋았다. 한인진의 간보호 효과 시험에서는 한인진 추출물을 경구투여한 V, IV군의 간무게, 체중에 대한 간무게의 비율이 생리 식염수만을 투여한 III군보다는 낮았으나 시료 채취전후로 한인진 추출물을 경구투여한 V군과 IV군사이에는 별다른 차이점이 없었다. 예방효과를 알아보기 위해 10일간 실험을 실시한 결과 한인진 물추출물만을 단독 투여한 VI군의 체중은 계속 증가하였으나 한인진 물추출물을 계속 투여한 다음 시료 채취전에 사염화탄소를 투여한 VIII군의 간무게, 체중에 대한 간비율이 대조군 VII보다 다소 감소하였다. 병리학적인 소견으로 한인진추출물을 투여 한 군에서는 사염화탄소만 투여한 군보다 간세포의 괴사와 지방적의 축적이 감소하여 사염화탄소에 의한 간독성에 효과가 있는 것으로 사료된다.