검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 55

        41.
        2012.11 서비스 종료(열람 제한)
        This study presents bond performance of insulated concrete sandwich panel systems considering different type of insulation through two-way acting insulated concret sandwich panel mock-up test under wind pressure.
        42.
        2012.11 서비스 종료(열람 제한)
        This paper analyzed the CO2 emission of existing buildings on the operation phase in the declined residential area of Jeonju old town. The average CO2 emission to square meter of residential buildings in jeonju was calculated.
        43.
        2012.02 KCI 등재 서비스 종료(열람 제한)
        To compare the effects of two external forcing on track of typhoon, TWRF(Typhoon WRF) based ensemble experiments are carried out in the case of Typhoon Morako which is the 8th typhoon at Northwest Pacific region in 2009. The two forcing are tropical SST and topography induced thermal and mechanical forcing, respectively. According to the result of numerical experiment for five-day forecast, the effect of mechanical forcing is about two times stronger than thermal forcing on the track error of the typhoon. More case study for other typhoon will be done as a next paper.
        44.
        2010.11 KCI 등재 서비스 종료(열람 제한)
        본 논문에서는 노후화된 부재의 내력평가 및 보강설계를 위한 기본 자료를 구축하기 위하여 기존 공동주택에서 채취한 철근콘크리트 기둥에 대한 구조실험을 통하여 노후화된 부재의 내력특성을 분석하고자 하였다. 이를 위하여 기존 재건축 아파트 현장에서 총 10개의 기둥을 채취하고, 각각의 기하학적 특성에 따라 중심축력 및 편심축력 실험을 실시하였다. 채취된 부재의 치수는 도면과 최대 40mm 정도 차이가 있었으며, 철근 피복두께는 약 25∼115 mm 정도의 범위로서 매우 고르지 못한 분포를 나타냈다. 본 실험결과에 의하면 모든 부재의 실험 압축내력이 계산치보다 최소한 75% 이상 큰 것으로 나타나 현행 설계기준을 만족하는 것으로 파악되었다. 그러나, 부재의 변위 연성비는 최소 2.12, 최대 5.86으로 나타나 전반적으로 부족한 것으로 파악되었다.
        45.
        2010.05 KCI 등재 서비스 종료(열람 제한)
        본 논문에서는 리모델링 공사에 있어 요구되는 노후화된 부재의 내력평가 및 보강설계를 위한 기본 자료를 구축하기 위하여 기존 공동주택의 해체공사시 채취한 철근콘크리트 보 부재에 대한 구조실험을 통하여 노후화된 부재의 내력특성을 분석하고자 한다. 이를 위하여 기존 재건축 아파트 현장에서 총 10개의 보 부재를 채취하고, 각각의 기하학적 특성에 따라 정적 휨 또는 전단내력 실험을 실시하였다. 본 실험결과에 의하면 모든 부재에서 계산치 이상의 실험 내력값을 얻을 수 있었으나, 콘크리트 타설불량 및 심각한 균열이 관측된 일부 실험체에서는 취성적인 파괴와 더불어 낮은 내력값을 나타내었다. 따라서 이러한 심각한 균열/손상 등은 리모델링 공사에 앞서 적절히 보수․보강되어야 할 것으로 판단된다.
        46.
        2010.01 KCI 등재 서비스 종료(열람 제한)
        본 논문에서는 FRP 복합체로 보강된 콘크리트 구조물의 동결융해 저항성을 평가하기 위하여 동결융해 진행에 따른 FRP 복합체의 인장강도 및 콘크리트에 대한 인발접착강도의 변화를 측정하였다. 주 실험변수는 동결융해 조건, FRP 복합체의 종류, 동결융해 싸이클로 설정하였다. KS F 2456의 동결융해 시험규격에 따라 실시된 탄소섬유복합체의 인장강도는 최종 싸이클까지 변화가 없었으며, 또한 접착성능의 저하도 관측되지 않아 CFRP의 동결융해 저항성은 매우 우수한 것으로 나타났다. 이에 대하여 유리섬유복합체의 경우는 최종 싸이클에서의 인장강도 및 인발접착강도가 각각 10%, 15% 저하된 것으로 나타나 부분적으로 성능이 저하되는 것으로 나타났다. 그러나 접착강도 평가시 지속적인 동결수가 공급되는 상황에서는 상이한 결과가 나타날 수 있으므로 이에 대한 주의가 필요할 것으로 판단된다.
        47.
        2009.10 KCI 등재 서비스 종료(열람 제한)
        In this paper, changes in the intensity (e.g., central pressure and maximum sustained wind speed) of Tropical Cyclone (TC) in summer in the regions located at 30 oN in East Asia from 1988 to 1991 were found. The intensity of TC from 1991 to 2007 was much higher than that of TC from 1965 to 1988. The reason for this was that the frequency of TCs passing China from 1991 to 2007 was much lower than that of TCs from 1965-1988 because a northeasterly wind caused by high-pressure circulation in East Asia got severer along the East Asian coast. Instead, TCs moved from the eastern region of the Tropical West Pacific to Korea and Japan mainly after passing the East China Sea due to the low-pressure circulation strengthened in the subtropical waters of East Asia. In addition, low Vertical Wind Shear (VWS) was created along the mid-latitude regions of East Asia and the main path of TCs from 1991 to 2007. Most of the regions in the Northwestern Pacific showed higher Sea Surface Temperature (SST) from 1991 to 2007, and had a good environment where TCs were able to maintain a higher intensity on the mid-latitude. In particular, a low sensible heat flux occurred due to high snow depth in East Asia in the spring of 1991 to 2007. Accordingly, the lower layer of East Asia showed high-pressure circulation, and the sea surrounding East Asia showed low-pressure circulation. Thus, the typical west-high, east-low pattern of winter atmospheric pressure was shown. The possibility of snowfall in East Asia in spring to be used as a factor for predicting the summer intensity of TC in the mid-latitude regions of East Asia was insinuated. The characteristics of TC in a low-latitude region were the same in Korea. The latest intensity of TCs got higher, and the landing location of TCs gradually changed from the west coast to the south coast.
        48.
        2009.05 KCI 등재 서비스 종료(열람 제한)
        This study found that tropical cyclones (TCs) formed for fall in 2007 over the western North Pacific were distributed in high-latitudes comparing to 56-year (1951-2006) climatological mean. The frequency and latitude of TC genesis became higher than 56-year climatological mean from September onward in 2007 and all the TCs that formed to the north of 20°N was also distributed after September in 2007. These characteristics of TC genesis for fall in 2007 could be confirmed through analyzing various variables, such as a large-scale atmospheric circulation, outgoing longwave radiation (OLR), vertical zonal wind shear, and sea surface temperature (SST). On the other hand, a frequency of the TC that occurred to the north of 20°N showed a clear interdecadal variation and its decreasing trend was distinctive in recent years. Its intensity was also weaker that TCs that did to the south of 20°N. However, a latitude of TC genesis showed an increasing trend until recent years, whose variation was consistent with trend that through a SST analysis, warm SST went north in recent years.
        49.
        2008.11 KCI 등재 서비스 종료(열람 제한)
        본 연구에서는 외부 부착 프리스트레스트 탄소섬유판으로 보강된 RC보의 휨거동을 분석하기 위한 실험연구를 수행하였다. 실험체는 프리스트레스 양을 변수로 축소모형으로 제작되었다. 또한 프리스트레스의 도입에 따른 구조성능 비교를 위하여 기준실험체와 단순부착 실험체를 함께 제작하였다. 실험결과, 단순 부착 탄소섬유판으로 보강된 부재는 조기 박리에 의해 탄소섬유판 인장강도의 50% 이하에서 최종파괴되었다. 그러나, 프리스트레스를 도입하여 보강한 실험체는 모두 탄소섬유판의 파단하중까지 도달하였다. 또한 프리스트레스 보강량의 증가에 따라서 균열하중, 항복하중은 증가하며 최대하중은 프리스트레스 양과 관계없이 일정한 것으로 나타났다.
        50.
        2008.11 KCI 등재 서비스 종료(열람 제한)
        본 연구에서는 외부 비부착형 프리스트레스트 탄소섬유판으로 보강된 RC보의 휨거동을 분석하기 위한 실험연구를 수행하였다. 실험체는 프리스트레스 양 및 정착장치의 형상을 변수로 총 10개로 제작되었다. 또한 프리스트레스의 도입에 따른 구조성능 비교를 위하여 기준실험체와 단순부착 실험체를 함께 제작하였다. 실험결과, 단순 부착 탄소섬유판으로 보강된 부재는 조기 박리에 의해 탄소섬유판 인장강도의 50% 이하에서 최종파괴되었다. 그러나, 프리스트레스를 도입하여 보강한 실험체는 모두 탄소섬유판의 파단하중까지 도달하였다. 또한 스터드형 정착장치를 적용한 실험체들의 보강성능은 매립형 정착장치를 적용한 실험체와 동등한 보강성능을 나타내었다.
        51.
        2008.05 KCI 등재 서비스 종료(열람 제한)
        FRP 복합체의 함침ㆍ접착에 사용되는 에폭시 수지와 같은 2액형 접착제는 두 성분을 상호 혼합함으로써 경화반응이 시작되며, 일정 시간이 경과되면 접착제의 점도와 온도가 급격히 증가된다. 이와 같이 접착제의 점도가 증가되면 작업성과 접착력이 저하되므로, 현장에서의 작업은 시공연도(workability)가 유지되는 한계, 소위「사용가능시간(pot life)」이내에 완료되어야만 한다. 본 연구에서는 구조보강용 FRP 복합체의 함침ㆍ접착에 사용되는 에폭시 수지의 사용가능시간을 평가하기 위하여 기존에 제안되고 있는 점도변화법 및 발열온도상승법의 적합성을 검증하고, 실험결과의 비교ㆍ분석을 통하여 구조용 접착제의 사용가능시간을 보다 합리적으로 산정할 수 있는 시험방법 및 평가기준을 제안하였다.
        52.
        2008.03 KCI 등재 서비스 종료(열람 제한)
        FRP와 콘크리트의 접착강도를 평가하기 위해 현장에서 일반적으로 사용되는 Pull-off 실험방법은 FRP 복합체의 손상을 초래하며 더욱이 FRP의 최대 pull-off 강도가 콘크리트의 인장강도에 의해 제한 되는 단점을 지니고 있다. 이에 따라 구조보강용 접착제의 역학적 특성을 1차적으로 평가할 수 있는 간접적인 실험방법의 개발이 요구된다. 본 연구에서는 여러나라에서 각기 제안되고 있는 실험규격에 대한 비교실험을 통하여 구조보강용 접착제의 역학적 특성을 개략적으로 예측할 수 있는 표준화된 실험방법 및 평가기준을 제안하고자 하였다. 본 연구결과를 바탕으로 인장전단접착강도 시험의 접착제 두께, 압축/휨강도 시험체의 제원 등이 통일되어 표준시험체 제원을 도출할 수 있었다.
        53.
        2008.01 KCI 등재 서비스 종료(열람 제한)
        본 논문에서는 RC 구조물의 보수ㆍ보강 공사에 적용되는 FRP 복합체의 역학적 특성치를 평가하기 위하여 각국에서 제안된 시험규격을 비교․분석하고, 시험편 형상 및 시험방법의 차이가 재료성능에 미치는 영향에 대한 실험적 검증을 통하여 표준화된 시험방법 및 평가기준을 도출하고자 하였다. 주 실험변수는 FRP 복합체의 종류, 시험편의 폭, 보강매수 및 가력속도로 설정하였다. 본 시험결과에 의하면, 최대 인장강도와 최소변동계수를 나타내는 인장 시험편의 폭은 FRP의 종류/직조방법에 따라 다르게 나타났으며, 특히 적층형으로 시공되는 FRP 복합체는 보강매수에 따른 인장강도의 저하현상이 관측되므로, 이를 적절히 고려할 수 있는 평가기준의 설정이 필요할 것으로 판단된다.
        54.
        2007.09 KCI 등재 서비스 종료(열람 제한)
        The impact of midlatitude synoptic system (upper-level trough) on typhoon intensity change was investigated by analyzing the spatial and temporal characteristics of vertical wind shear (VWS), relative eddy momentum flux convergence (REFC), and potential vorticity (PV). These variables were computed over the radial mean 300~1,000 km from the typhoon center by using GDAPS (Global Data Assimilation and Prediction System) data provided by the Korea Meteorological Administration (KMA). The selected cases in this study are typhoons Rusa (0215) and Maemi (0314), causing much damage in life and property in Korea. Results show that the threshold value of VWS indicating typhoon intensity change (typhoon to severe tropical storm) is approximately 15 m/s and of REFC ranges 6 to 6.5 ms-1day-1 in both cases, respectively. During the period with the intensity of typhoon class, PVs with 3 to 3.5 PVU are present in 360K surface-PV field in the cases. In addition, there is a time-lag of 24 hours between central pressure of typhoon and minimum value of VWS, meaning that the midlatitude upper-level trough interacts with the edge of typhoon with a horizontal distance less than 2,000 km between trough and typhoon. That is, strong midlatitude upper-level divergence above the edge of the typhoon provides a good condition for strengthening the vertical circulation associated with the typhoons. In particular, when the distance between typhoon and midlatitude upper-level trough is less than 1,000 km, the typhoons tend to weaken to STS (Severe Tropical Storm). It might be mentioned that midlatitude synoptic system affects the intensity change of typhoons Rusa (0215) and Maemi (0314) while they moves northward. Thus, these variables are useful for diagnosing the intensity change of typhoon approaching to the Korean peninsula.
        55.
        2007.09 KCI 등재 서비스 종료(열람 제한)
        본 연구에서는 아라미드섬유쉬트로 휨 보강된 RC 보의 파괴양상을 분석하고, 부착파괴를 방지하기 위한 실험연구를 수행하였다. 아라미드섬유쉬트의 부착파괴 방지상세에 대한 효과를 검증하기 위하여 총 5개의 실험체를 제작․실험하였다. 분석결과에 의하면 기존에 사용되어온 단순부착식이나 단부 U보강상세를 적용한 실험체는 아라미드섬유쉬트의 재료변형률보다 낮은 변형률에서 부착파괴되는 것으로 나타났다. 반면 본 연구에서 제안한 중앙부 U보강상세와 에폭시 전단키를 적용한 실험체는 아라미드섬유쉬트의 부착파괴를 억제함으로써 충분한 보강성능을 발휘하는 것으로 나타났다
        1 2 3