This study aimed to examine the effect of a mild elevation in serum cholesterol level in a porcine coronary overstretch restenosis model using a balloon angioplasty catheter or drug-eluting coronary stent. Pigs were divided into two groups and were fed a commercial normal diet (CND, n = 4) or a high-fat diet (HFD, n = 4) for 5 weeks. Coronary overstretch injury by balloon angioplasty or stent implantation was induced in the left anterior descending and left circumflex artery after 1 week of feeding. Histopathological analysis was performed at 4 weeks after coronary injury. During the experiment, the total cholesterol level in the HFD group increased by approximately 44.9% (from 65.9 ± 3.21 mg/dL at baseline to 95.5 ± 9.94 mg/dL at 5 weeks). The lumen area in the CND group was reduced in comparison with that in the HFD group after balloon angioplasty. After stent implantation, the injury score showed no significant difference. There were significant differences in the neointimal area (2.7 ± 0.33 mm2 in the CND group vs. 3.3 ± 0.34 mm2 in the HFD group, p<0.05), lumen area (2.6 ± 0.54 mm2 in the CND group vs. 2.0 ± 0.33 mm2 in the HFD group, p<0.05), and percent area stenosis (52.0 ± 7.96% in the CND group vs. 62.4 ± 5.15% in the HFD group, p<0.05). Body weight change was not different between the two groups. Increased serum cholesterol level activated vascular smooth muscle cell proliferation in the porcine coronary overstretch model.
Acute myocardial infarction (AMI) is considered the major cause of mortality in the world. Tremendous animal studies are performed to develop novel therapeutics, and this study aimed to induce porcine myocardial infarction model by using polyethylene terephthalate (PET). Coronary guidewire was placed in left anterior descending artery (LAD). The balloon angioplasty catheter was inserted at the back of the PET. The balloon catheter was carefully pushed forward, until the balloon marker was located in mid-LAD. Coronary angiography was performed pre- and post-occlusion at 28 days by C-arm. Histologic analysis of heart tissue was performed 28 days after inducing AMI. Thirty three pigs were anesthetized and underwent percutaneous coronary catheterization. All pigs were successfully embolized in mid-LAD by PET. Fifteen pigs died due to ventricular fibrillation during post-anesthetic recovery time, and overall experiment mortality was 45.5%. In 2,3,5- triphenyl tetrazolium chloride staining, gross finding of the ischemic heart lesion showed firm and white area of infarction associated with the apex and left ventricular posterior wall. Infarct on H&E-stained sections demonstrated a region without myocytes and rich with cardiomyocyte with atypical nuclei. Successful induction of AMI by using PET may provide the pathophysiological information of ischemic heart disease and improvement of therapy development for AMI.
방사선은 의학, 이공학, 농학, 기타 산업분야 등에서 사용영역이 매우 넓고 방사선이용기술의 개발로 방사선 의 이용 빈도는 계속 증가되고 있다. 방사선의 인류에 대한 공헌은 지대하지만 생체에 미치는 영향으로 인하여 방사선에 의한 장해 또한 간과할 수 없는 부분이다. 방사선을 유효적절하게 이용하면서 장해를 방지하기 위해 서는 방사선을 정확하게 계측하여야 하며 이에 따른 연구와 교육이 철저하게 이루어 져야만 한다. 본 연구에 서는 유비쿼터스 컴퓨팅기술을 이용하여 생체에 유해한 작용을 하는 방사선을 방사선선원에 접근하지 않고 무 선으로 시간과 장소에 제한 없이 방사선을 계측할 수 있는 방안을 제안하였다. 제안된 방안의 구현은 무선전송 기술은 CDMA망을 이용하였고, 임베디드시스템(embedded system)을 PDA에 내장한 후, 고정된 IP를 가지는 방 사선계측시스템에 PDA를 CDMA망에 접속하여 계측값을 디스플레이 하였다. 본 연구에서 제안된 방안을 이용 한다면 인간이 유해한 방사선선원에 접근하지 않고 선원에 배치된 고정된 IP를 가지고 있는 방사선계측시스템 을 통하여 CDMA망으로 PDA에 표시된 계측값을 읽을 수 있게 될 것이다.
본 연구에서는 PDA 기반의 블루투스를 이용한 무선통신 방사선 측정 장치를 개발하였다. 제안하는 시스템 은 방사선 측정 센서로 GM (Geiger-Mueller) 계수관을 이용하는 Vernier사의 Student Radiation Monitor, 데이터 획득을 위한 모듈로는 Vernier사의 LabPro, 데이터의 무선전송을 위하여 Initium사의 최대 30미터까지 블루투스 통신이 가능한 Promi-SD 101, 데이터의 저장과 디스플레이에는 운영체계로 Pocket PC 2003이 내장된 HP사의 5550으로 구성하였다. 방사선측정센서로 GM 계수관을 이용하였으므로 방사선 에너지 측정은 불가능하고 카운 트 양과 카운트율을 측정할 수 있다. PC를 이용한 시스템의 자연방사선 계측치와 PDA를 이용한 시스템의 자연 방사선 계측치를 비교한 결과, 제안하는 시스템은 자료의 왜곡 없이 송수신이 이루어지고 있음을 확인하였다.