검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 9

        1.
        2016.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        We have constructed a wide-field photometric survey system called as the Korea Microlensing Telescope Network (KMTNet) in 2015. It consists of three 1.6 m optical telescopes equipped with mosaic CCD cameras. Four 9k CCDs were installed on the focal plane of each telescope. In this paper, we present the crosstalk analysis of the KMTNet mosaic CCD images. The crosstalk victims caused by bright sources were visible at eight sub-images obtained through different readout ports of each CCD. The crosstalk coefficients were estimated to be several tens of 10-4 in maximum, differing from sub-image to sub-image, and the non-linearity effect certainly appeared at the victims made from saturated sources. We developed software functions to correct the crosstalk effect of the KMTNet CCD images. The software functions showed satisfying results to remove clearly most of the crosstalk victims and have been implemented in the KMTNet image processing pipeline since 2015 September.
        4,000원
        3.
        2015.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The IGRINS is a near infrared high resolution spectrograph jointly developed by the Korea Astronomy and Space Science Institute and the University of Texas at Austin. We present design and fabrication of the optomechanical mount for the five mirrors, i.e., an input fold mirror, a slit mirror, a dichroic, and two camera fold mirrors. Based on the structure analysis and the thermal analysis of finite element methods, the optomechanical mount scheme satisfies the mechanical and the thermal design requirements given by the optical tolerance analysis. The performance of the fabricated mirror mounts has been verified through three IGRINS commissioning runs.
        4,500원
        5.
        2013.06 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        Star clusters are superb astrophysical laboratories containing cospatial and coeval samples of stars with similar chemical composition. We initiate the Sejong Open cluster Survey (SOS) - a project dedicated to providing homogeneous photometry of a large number of open clusters in the SAAO Johnson-Cousins’ UBV I system. To achieve our main goal, we pay much attention to the observation of standard stars in order to reproduce the SAAO standard system. Many of our targets are relatively small sparse clusters that escaped previous observations. As clusters are considered building blocks of the Galactic disk, their physical properties such as the initial mass function, the pattern of mass segregation, etc. give valuable information on the formation and evolution of the Galactic disk. The spatial distribution of young open clusters will be used to revise the local spiral arm structure of the Galaxy. In addition, the homogeneous data can also be used to test stellar evolutionary theory, especially concerning rare massive stars. In this paper we present the target selection criteria, the observational strategy for accurate photometry, and the adopted calibrations for data analysis such as color-color relations, zero-age main sequence relations, Sp - MV relations, Sp - Teff relations, Sp - color relations, and Teff - BC relations. Finally we provide some data analysis such as the determination of the reddening law, the membership selection criteria, and distance determination.
        5,700원
        6.
        2003.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        We have developed a seeing monitoring system and measured seeing variation of the Bohyunsan Optical Astronomy Observatory (BOAO) and the Sobaeksan Optical Astronomy Observatory (SOAO) using a small telescope system. Our seeing monitoring system is similar to the differential image motion monitor (DIMM) installed at the ESO. The ooly difference between the BOAO and the SOAO seeing monitoring system is a detector system, a video camera at the BOAO and ST-4 camera at the SOAO. We confirmed that the seeing monitoring system at the SOAO can measure average seeing size inspite of its simple detector system. From the BOAO seeing measurement, we found that the seeing size changes fast. We expect that our seeing monitoring system could be used for real time seeing monitoring after some improvement, and the data to be obtained would be very useful when we build adaptive optic system in the future.
        4,000원
        7.
        2002.12 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        Cassegrain interface module (CIM) of the fiber-fed high resolution echelle spectrograph has been designed and manufactured for the 1.8 m reflector at the Bohynsan Optical Astronomy Observatory. We also constructed a long slit spectrograph attached to this CIM, which would replace the earlier rather inefficient medium dispersion spectrometer. We present detailed description for design and manufacturing concepts of the CIM which consists of a slit assembly, slit monitoring system, calibration lamp system and a long slit spectrograph, in order to provide how the overall system and each part. are constructed. The preliminary performance test carried out so far seems to indicate a successful result.
        4,000원
        8.
        2001.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        We developed a CCD camera that can observe wide fields on the sky. We tested the field of views using various lenses. For cooling the CCD chip, we used a thermoelectric cooling device and tested the cooling efficiency. This camera will continuously observe a part of the sky. The data from the camera will be used to decide the current weather condition by the real-time star counting program (SCount) which will be developed later.
        4,000원
        9.
        2001.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        We present the characteristics of the 2K CCD camera at the Bohyunsan Optical Astronomy Observatory of the Korea Astronomy Observatory at the time of its development. The purpose of this paper is to support the observers who may need detailed information on the characteristics of the camera and to provide helpful information on the optimization' of a CCD camera for those who try to develop their own camera. The 2K CCD camera was optimized to have a gain of 1.8e−/ADU and a read out noise of 7e− from an experiment using radioactive 55 Fe X-ray source. The charge transfer efficiency was measured as 0.9999976 for serial and 0.9999942 for parallel direction, which means 0.5% charge loss along the serial direction and 1.2% along the parallel direction across the chip. The quantum efficiency of the camera was measured from an experiment using a homogeneous light source consisting of a halogen lamp and an integrating sphere with a monochromator. The resulting quantum efficiency of the camera peaked at the wavelength range 600-700 nm with the value of \-0.89 .
        4,000원