The 3-way valve have been used as a valve for opening and closing the valve by the flow control in the pressure system of the cryogenic and high pressure environment. In this paper, numerical analysis and experimental study on fracture nipple of 3-way ultra high pressure valve applied to space launch vehicle was carried out. We have developed a 3-way valve numerical simulation modeler of cryogenic environment using commercial software ANSYS 18.2. As results of numerical analysis, optimum nipple condition was derived. In addition, a 3-way valve prototype was fabricated and the fracture test was performed and compared with the numerical analysis results.
Orthodontic is important to apply the optimal orthodontic force. The orthodontic bracket is deformed and the stress caused by tension and torsion of the wire. In this study, using the ANSYS the material that is currently widely used in orthodontic bracket material of stainless steel, ceramic, titanium, polycarbonate, by applying the nitinol analyzed the strain and the stress distribution on the bracket side. Simulation results on the stress distribution and deformation, and it was found a difference of each material.