검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 2

        1.
        2012.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this paper, we propose a new re-quantization method after FFT processing to prevent the distortion of correlation result of VCS (VLBI Correlation Subsystem). The re-quantization is used to rearrange the data bit so as to reduce the data rate processed as 16-bit of FFT result of VCS. Having done this procedure, we found that the distorted spectrum of correlation result occurred in the delay tracking experiments by the re-quantization method introduced for initial design of VCS. In order to solve this, two kinds of re-quantization method, that is, the comparison and selection-type, are proposed. The first is to re-quantize the FFT result as a valid-bit by comparing with the input data after determining the adequate threshold. The second is manually to select the valid-bit of FFT result after finding the valid-field of data according to the bit-distribution of input data. We confirmed that the second is more effective compared with the first through the experimental result, and it will be implemented without so much modification of applied method in the condition of the limited resource of FPGA. The re-quantization is, however, carried out with 4-bit in the proposed second method for FFT result, and then the distortion of correlation result is also appeared. To fix this problem, the bit for re-quantization is extended to 8-bit. The proposed 8-bit selection-type is effectively verified so that the distortion of correlation result disappeared by applying to VCS in consequence of the simulation and correlation experiments.
        4,200원
        2.
        2012.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this paper, we describe the installation of VLBI Correlation Subsystem (VCS) main product and its performance at the Korea-Japan Correlation Center (KJCC). The VCS main product was installed at KJCC in August 2009. For the overall performance evaluation of VCS, playbacks, Raw VLBI Data Buffer (RVDB) system, and Data Archive (DA) system were installed together. The VCS main product was connected between RVDB and DA, and the correlation results were put into the DA to confirm the normal operation of VCS 16 station mode configuration. The evaluation test was first performed with 4 station mode, same as the factory test of VCS main product. Based on the results of 4 station mode, the same evaluation test was conducted for 16 station mode of VCS. We found that the correlation results of VCS were almost similarly compared to those of the Mitaka FX Correlator. Through the test results, we confirmed that the problems such as spectrum errors, delay parameter processing module and field programmable gate array errors in antenna unit, which were generated at the factory test of VCS main product, were clearly solved. And we verified the performance and connectivity of VCS by obtaining the expected correlation results and we also confirmed that the performance of VCS was sufficient for real VLBI observation data in both 4 and 16 station modes.
        4,900원