The correlation among gaseous air pollutants (odorous compounds, greenhouse gases) and meteorological parameters was analyzed in-depth using measurement data at a barn and ambient in a naturally ventilated dairy farm. Both concentration and emission data (loading rate and emission rate), which more accurately express the actual pollutant emissions, were used in the correlation analysis. Gaseous air pollutants (ammonia, hydrogen sulfide, carbon dioxide, nitrous oxide, methane) and meteorological factors (relative humidity, temperature, wind speed, solar strength) were measured for one week in July 2013. The upper and lower outliers of measured data by inducing 1.5 times the interquartile range (IQR) were eliminated. After eliminating the outliers and grouping according to data magnitude, the correlation analysis among gaseous compounds and meteorological factors was conducted using the average values of each group. In the correlation analysis, data for the emission rate (barn) and the loading rate (ambient) showed a better correlation than concentration data. Gaseous air pollutants except for hydrogen sulfide in the barn showed a good correlation. Hydrogen sulfide might not be produced from manure or animal origin. Rather, the compound may be produced by flushing water, which was flushed at periodical times (every six hours). Ammonia emissions increased with increasing temperature, and this increase can be affected from greater exertion of feces by frequent water drinking in a high-temperature condition. In the ambient, the correlation for all gaseous air pollutants was better than that in the barn, because those air pollutants from manure, animals, and flushing water origins were sufficiently mixed in the atmosphere. Wind speed also showed a good correlation with all gaseous air pollutants.
폐기물을 사용한 가스화 공정에서 발생되는 합성가스는 폐기물의 특성상 분진, 타르 외에도 HCl, HCN, NH3 등 다양한 종류의 가스상 물질을 함유하고 있어 이들 가스상 물질로 인해 생물체에 해를 주거나 환경의 정상적인 기능을 저해하는 대기오염문제를 야기할 수 있다. 따라서 폐기물 기반의 합성가스를 활용하기 위해 이러한 대기오염물질들을 제어할 수 있는 정제 과정이 필요하다. 본 연구에서는 폐기물에서 발생한 합성가스에서 가스상 대기오염물질을 포집하여 각 정제설비 후단에서의 농도를 확인하여 정제설비의 가스상 대기오염물질 제거 효율을 파악하였다. 본 연구에서의 합성가스 정제설비는 급속냉각탑, 벤츄리 스크러버, 중화세정탑, 탈황세정탑, 습식전기집진기를 사용하였으며, 가스상 대기오염물질은 가스화로 후단, 중화세정탑 후단, 습식전기집진기 후단에서 각각 포집하였다. 3종류(HCl, HCN, NH3)의 포집을 위해 HCl은 0.1 N-NaOH, HCN은 0.5 N-NaOH, NH3는 0.5wt%의 H3BO3을 사용하였으며, 분당 2L의 유량으로 20분간 포집하였다. 폐기물 기반 합성가스의 가스상 대기오염물질 정제설비의 총괄 제거 효율은 HCl이 98.58%, HCN은 87.30%, NH3 는 99.68%로 나타났다. 또한, 급속냉각탑, 벤츄리스크러버, 중화세정탑의 가스상 대기오염물질 제거 효율은 HCl 92.13%, HCN 66.02%, NH3 91.40%로 나타났다.