본 연구는 반복 횡하중 하에서 CFRP(Carbon Fiber Reinforced Polymer) Sheet로 보강된 철근콘크리트 프레임면내 조적벽체의 전단내력을 평가하여 국내 조적벽체 학교 건축물에 적합한 CFRP Sheet 보강 방안을 제안하는 것에 그 목적이 있다. 조적 허리벽이 있는 1층, 1경간, 1/2 스케일의 시험체를 4개 제작하여 CFRP Sheet의 보강량을 변수로 실험을 수행하였으며 이를 통하여 보강량에 따른 강도와 강성의 변화를 분석하였다. 실험 결과 CFRP Sheet는 시험체의 내력과 강성을 향상시켰으며 특히 기둥과 조적벽을 모두 보강하는 방법을 통한 보강방법에 있어 그 적용성을 확인할 수 있었다.
This paper describes an experimental program to investigate the shear behavior of insulated concrete sandwich panels (CSPs) with different types of GFRP shear connector. The study included testing of 13 insulated CSP specimens with two types of surface conditions for extruded polystyrene (XPS) insulation and various shapes of shear connectors. All specimens were loaded in direct shear by means of push-out and were consist of three concrete panels, two insulation layer and four rows of GFRP shear connectors. Load-relative slip between concrete panel and insulation response of CSP specimens has been established through push-out shear test. Test results indicate that the surface condition of insulation has a significant effect on the bond strength between concrete panel and insulation. The specimen used XPS foam with 10mm deep slot shows higher bond strength than those used XPS foam with meshed surface. Corrugated GFRP shear connectors show equivalent strength to grid GFRP shear connectors. Cross-sectional area and embedded length of shear connector have a notable effect on overall response and inplane shear strength of the CSP specimens.
To evaluate the shear strength of unreinforced masonry wall with/without a opening, analysis is conducted with/without a opening. As a result, the strength, stiffness, displacement are evaluated by using analysis program. Using this method, it is abel to evaluate the seismic performance of unreinforced masonry wall
Experimental observations and theoretical predictions were presented for a total of 8 reinforced concrete wall with all sides being exposed to ISO standard heating curve. In the modeling of wall axial deformation under constant load at varying elevated temperature conditions, numerical models on heat transfer and spalling were considered along with the mechanical model. Based on the model, preditions on the fire resistance of the bearing wall under the axial load was presented.
This paper describes the structural behavior of insulated concrete wall panels with no-bond stress insulation. That panels reinforced with fiber reinforced polymer (FRP) truss shear connector to achieve composite action of inner and outer concrete wythes. Main test variable is bond stress. According to the test result, the shear capacity of increased due to bond stress and reinforced with FRP truss shear connector.
This study was shear strength of insulated concrete sandwich panels with tress shear connector. Specimens with results XPSSTG insulation than the EPS insulation was good in the Shear Strength. The maximum displacement is better than the EPS specimens and that of the specimens XPSSTG trends that appear are considered.
일반적으로 조적조는 석재, 벽돌, 시멘트블록 등의 조적 개체와 모르타르(motar) 등 이종재료로 구성된 적층구조로서, 우리나라뿐만 아니라 전 세계적으로 가장 오래되고 광범위하게 사용되어진 구조재료이다. 그러나 수직하중에 대한 큰 저항능력에 비해 횡력에 매우 취약한 단점을 갖고 있으며, 최근에 발생한 지진피해사례에서도 저층의 조적조 건축물의 피해가 많이 보고되고 있다. 따라서 본 연구에서는 수평전단력 향상을 위하여 기존 사각형 블록 벽체에서 발생되는 횡방향 통줄눈을 방지하여 횡력에 대한 저항력을 높여줄 수 있는 육각형 형태의 블록을 개발하고, 개발된 블록을 사용한 조적 벽체의 구조실험을 수행하여 거동특성과 전단강도의 증가효과 등을 분석하며, 신축 및 건물 리모델링시에 내진보강용으로 사용할 수 있는 조적조를 제안하고자 하였다. 개발된 중공형 및 솔리드형 블록을 사용하여, 블록의 형상 및 수직 철근 보강량 및 배열위치를 변수로 육각형 블록 벽체의 구조실험을 수행 하였으며, 기존 사각형의 조적조 벽체에 비교하여 상대적으로 연성적인 거동과 전단저항 능력의 향상을 확인할 수 있었다.
본 논문의 목적은 경량기포모르터를 충전한 스틸스터드와 복합스터드 내력벽체의 내화성능을 KS규준에 따라 평가하는데 있다. 주거용과 상업용 건물의 최소 내화 요구시간은 2시간이다. 시험 결과로부터 스틸 스터드와 복합스터드에 경량기포 모르터를 충전한 두 시험체 모두 2시간 내화 성능을 만족하는 것으로 나타났다. 또한 복합스터드 패널 시험체의 경우 내화 성능면에서 스틸 스터드 패널 시험체 보다 우수하다는 것을 정량적 평가하였다.