검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 6

        1.
        2023.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Numerous studies have established a correlation between sociodemographic characteristics and water usage, identifying population as a primary independent variable in mid- to long-term demand forecasting. Recent dramatic sociodemographic changes, including urban concentration-rural depopulation, low birth rates-aging population, and the rise in single-person households, are expected to impact water demand and supply patterns. This underscores the necessity for operational and managerial changes in existing water supply systems. While sociodemographic characteristics are regularly surveyed, the conducted surveys use aggregate units that do not align with the actual system. Consequently, many water demand forecasts have been conducted at the administrative district level without adequately considering the water supply system. This study presents an upward water demand forecasting model that accurately reflects real water facilities and consumers. The model comprises three key steps. Firstly, Statistics Korea’s SGIS (Statistical Geological Information System) data was reorganized at the DMA level. Secondly, DMAs were classified using the SOM (Self-Organizing Map) algorithm to consider differences in water facilities and consumer characteristics. Lastly, water demand forecasting employed the PCR (Principal Component Regression) method to address multicollinearity and overfitting issues. The performance evaluation of this model was conducted for DMAs classified as rural areas due to the insufficient number of DMAs. The estimation results indicate that the correlation coefficients exceeded 0.9, and the MAPE remained within approximately 10% for the test dataset. This method is expected to be useful for reorganization plans, such as the expansion and contraction of existing facilities.
        4,200원
        2.
        2018.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The results of the survey on water utilization status, the wasted water factor, the awareness, and the education and promotional activities of water saving in Daejeon City are as follows: The percentage of using tap valve with a closure was 66% when showering. 74% of water was used with closing the tap valve when washing faces with no water needed, it was still considered that there existed a wasting water. The most wasting reasons of water were found to be shower, bath, and laundry in order. In the awareness of practicing tap water saving, 9.1% of respondents acted actively, 53.4% of them were trying to practice it, and more than 63% had a positive awareness. In the contents of practicing saving water, locking water when soaping while showering, non-laundry of small quantity, and using cups when brushing teeth were top priorities. About 50% of the reasons for saving water was to practice purely saving water, when saving for economic help was excluded. The level of water saving awareness was not high when considering that the ratio of usage without water saving equipment and installation, and using method was relatively high when moving in. In order to make usage of water saving equipment more common, it was deemed necessary to provide information on the purchase of water saving equipment and to promote and educate the efficiency of saving of related products. More than about 90% of the respondents responded that water saving education or promotional activities had an effect of improving water saving awareness. The most effective method of education and promotional activities was found to be 40.4% by mass media activities, and 21.7% by promotions through mobile devices.
        4,000원
        3.
        2018.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Maintaining adequate residual chlorine concentration is an important criteria to provide secure drinking water. The chlorine decay can be influenced by unstable flow due to the transient event caused by operation of hydraulic devices in the pipeline system. In order to understand the relationship between the transient event and the chlorine decay, the probability density function based on the water demand curve of a hypothetical water distribution system was used. The irregular transient events and the same number of events with regular interval were assumed and the fate of chlorine decay was compared. The chlorine decay was modeled using a generic chlorine decay model with optimized parameters to minimize the root mean square error between the experimental chlorine concentration and the simulated chlorine concentration using genetic algorithm. As a result, the chlorine decay can be determined through the number of transients regardless of the occurrence intervals.
        4,000원
        4.
        2013.06 구독 인증기관 무료, 개인회원 유료
        This study analyzed agricultural water distribution systems for the utilization of water demand-oriented water supply systems. Three major TM/TC(telemeter/telecontrol) districts of agricultural water management were selected for analyzing the characteristics of the water distribution systems. In addition, the characteristics of the water supply systems for general water supply zones based on irrigation facilities were also investigated, along with the case of special water management during the drought season. As a result, high annual and monthly variations were observed for the water supply facilities, including the reservoirs and pumping stations. In particular, these variations were more obvious during the drought season, depending on the type of facility. The operations of the pumping stations and weirs were more sensitive to the stream levels than the reservoirs, and the smaller reservoirs were influenced more than the larger reservoirs. Therefore, a water-demand-oriented water supply system should consider the existing general practices of water management in the agricultural sector, and focus on achieving a laborsaving system rather than water conservation in the case of reservoirs. Equal water distribution from the start to the end point of irrigation channels could be an effective solution for managing pumping stations.
        4,000원
        6.
        1998.06 KCI 등재 서비스 종료(열람 제한)
        시계열자료의 분해능력이 뛰어난 wavelet 변환을 사용하여 물소비특성을 분석하였다. Wavelet 변환의 기저함수로는 물수요량의 경우 Coiflets5 함수, 기온측정치의 경우 Coiflets3 함수를 사용하였으며 해석결과 212 scale에서 목표된 장기간에 걸친 변화추이는 hyperbolic tangent 함수의 형태로 전기간에 걸처 꾸준한 증가세를 보였다. 또한 절기혹은 경기주기와 밀접한 관련이 있을 것으로 생각되는 추가수요가 6월과 12월말을