This study aims to propose a simplified equation for estimating the bond strength of corroded reinforcing bars. To this end, extensive parametric analyses were performed using the detailed analysis method presented in the authors’ previous study, where a wide range of critical variables were considered, such as compressive strength of concrete, net cover thickness, and reinforcing bar diameter. The sensitivity in bond strength of the corroded reinforcing bar according to each variable was evaluated. On this basis, a simplified formula for the bond strength of the corroded reinforcing bar was derived through regression analysis. The proposed equation was rigorously tested and verified using the bond test results of corroded reinforcing bars collected from the literature. The results confirmed that the proposed equation could estimate the bond strengths of specimens with better accuracy than the existing models, providing a reliable tool for engineers and researchers. In addition, the proposed equation was used to analyze the development length required for corroded tensile reinforcement to exert its yield strength, and it showed that the cover thickness of concrete must be at least four times the diameter of the reinforcing bar to achieve the yielding strength of reinforcing bar even at a corrosion degree of more than 5.0%.
철근의 부식 문제를 해결하기 위해 최근 복합재료 기반의 철근이 개발되어 사용되고 있으며 CFRP 그리드도 개발되어 구조부재로 사용되기 시작하고 있다. 그러나 CFRP 그리드의 부착 특성과 응력을 연구한 경우는 매우 드물다. 이에 본 실험은 CFRP 그리드의 부착거동, 부착응력을 평가하고 정착길이를 산정하기 위해 다양한 길이의 정착길이를 가진 인발실험체를 제작한 후 인발하였으며 실험 결과 부착력의 경우 정착길이가 길어질수록 커지며 반대로 부착응력은 정착길이가 길어질수록 작아지는 결과를 얻을 수 있었다. 이는 FRP 보강근도 같은 경향을 보이지만 CFRP 그리드와 FRP 보강근의 차이점은 부착응력의 추세선의 경향에서 두드러지며 또한, 최대 부착력 이후 거동에서 차이를 나타냈다. 위 실험 결과를 토대로 CFRP 그리드의 정착길 이를 산정한 결과 본 연구에서 사용된 CFRP 그리드의 보수적인 정착길이는 250mm로 나타났다.
This research presents assessmental FRP plate, one of materials used for reinforcing damage of RC structure caused by deterioration. in order to investigate effective bonding length and bonding strength according to material property of epoxy used for bonding between FRP-Concrete, experimental tests for 3 specimens with each bonding length of 50,100,150,200and 250mm respectively are performed. test results indicate frat material property of epoxy can affect effective bonding length of FRP-Concrete.
Change in the adhesion strength between AR-glass textile and concrete was performed through pull-out test with longitudinal (load direction) and transverse development length. In case of longitudinal development length, adhesion performance was not shown. But in case of transverse, adhesion performance was increased according to the increasing transverse textile length.
In the case of cultural properties, each member has a cultural value and replacing of damaged wood is not easy. In addition, state of our country research for repair and reinforcement of timber are still incomplete. since 2008, research of the reinforcement method using CFRP plate has started. in this study, experiment for the adhesion strength along attachment length of surface bonded and NSM using CFRP plate. As a result, the adhesive strength is increased depend on increased of the adhesion area, measured the change of intensity according to the species of the wood.
본 연구는 부착재료의 변화 및 동결융해에 따른 FRP-콘크리트구조물 경계면의 거동을 조사하였다. 실험 시 고려된 연구변수로는 부착경계면의 부착강도, 경계면 유효부착길이 등을 조사하였다. 경계면 부착재료에 따른 거동변화 실험체의 경우 FRP-구조물 부착경계면에 사용되는 에폭시의 종류를 각각 3가지로 분류하며 FRP-콘크리트간 다양한 부착길이를 고려하여 시편을 제작하였으며 동결융해에 따른 경계면 거동조사의 경우 0 cycle에서 300cycle까지 계속적으로 증가되는 주기에 대하여 실험체들을 제작, 장기거동 부착실험을 수행하였다. 본 실험결과, 적용 부착재료의 종류에 따라 최대 유효부착길이는 5~7% 차이가 있었으며 동결융해 주기증가에 따른 최대부착하중 및 유효부착길이의 경우 초기에 나타난 급격한 거동변화 이후 상대적으로 불규칙한 변화를 장기적으로 나타내었다.
본 연구에서는 철근과 같은 기계적 맞물림 현상을 활용하기 위하여 이형리브가 형성되어 있는 GFRP 보강근을 제작하여 철근대체 재료로 사용하기 위해 FRP 보강근의 부착성능을 규명하고자 한다. 하지만 지금까지 많은 기존 연구자들이 부착성능에 대한 실험으로 단순 1방향(수직, 수평)인장실험으로 철근과 콘크리트 또는 FRP 보강근과 콘크리트사이의 부착특성을 고찰하여 두 재료 사이의 부착-슬립에 관한 제안식을 도출해왔다. 국내에서는 아직까지 GFRP 보강근의 부착에 대한 관심이 증대대고 있는 실정이지만 피로부착에 관한연구는 미흡한 편이이어서 GFRP 보강근의 피로 연구가 필요로 하다. 본 연구에서는 BRITISH STANDARD에서 규정하고 있는 방법에 의하여 휨 부착 시험체를 제작하여 정적 휨 부착실험 최대파괴하중의 70% ~ 90%의 하중으로 반복하중재하 후 정적실험을 통하여 GFRP로 보강된 콘크리트 피로부착 성능을 검증하였다