Currently, the construction trend of high-rise structures is changing from a cube-shaped box to a free-form. In the case of free-form structures, it is difficult to predict the behavior of the structure because it induces torsional deformation due to inclined columns and the eccentricity of the structure by the horizontal load. For this reason, it is essential to review the stability by considering the design variables at the design stage. In this paper, the position of the weak vertical member was analyzed by analyzing the behavior of the structure according to the change in the core position of the twisted high-rise structures. In the case of the shear wall, the shear force was found to be high in the order of proximity to the center of gravity of each floor of the structure. In the case of the column, the component force was generated by the axial force of the outermost beam, so the bending moment was concentrated on the inner column with no inclination.
In this paper, a twisted shape structure with an elevation form favorable to the resistance of vibration caused by wind loads is selected from among the forms of high-rise buildings. The analytical model is a square, triangular, and hexagonal plane with a plane rotation angle of one degree from 0 to 3 degrees per each story. As a result of the analysis, as the twist angle increased, story drift ratio is increased. Responses with different eccentricity rates were shown by analytical models. Therefore planar shapes designed symmetrically to the horizontal axis of X and Y are considered advantageous for eccentricity and torsion deformation. In the case of the bending moment of the column, the response was amplified in the column supporting the base floor, the roof floor, the floor in which the cross-section of the vertical member changes, and the floor having the same number of nodes as the base floor. Finally, the axial force response of the column is determined to be absolutely affected by the gravity load compared to the lateral load.
본 연구에서는 변장비 1:5인 플레이트거더 단면에 대하여 주거더의 위치 및 개수를 달리한 총 7종류의 단면을 대상으로 풍동실험을 통하여 비틀림 응답특성을 파악하였다. 본 연구에서 얻어진 결과로서 2-거더 단면의 경우 진폭이 큰 2회의 와류진동이 발생하는 등 동적 안정성에 문제가 있었으나, 하부 거더의 개수를 1개 또는 2개를 추가한 경우, 플러터 한계풍속이 증가되었고 와류진동의 최대진폭이 감소하고 발생영역이 축소되는 등 거더의 추가가 내풍안정성 향상에 효과가 있음을 알 수 있었다. 또, 브래킷부를 두는 경우, 와류진동의 안정성이 향상되는 것을 확인하였으며 브래킷 길이가 증가할수록 (-)영각에서의 발산진동에 대한 한계풍속이 증가됨을 알 수 있었다.
최근 우리나라의 대도시에서는 주거와 상업기능을 동시에 갖는 복합용도의 건축물이 많이 건설되고 있는데, 이러한 건물은 대부분 하부골조에서 연층, 약층 또는 비틀림 비정형을 띠게 된다. 본 논문의 목적은 이러한 건물의 지진응답을 실험을 통해 관찰하는 것으로서 1:12 축소모델의 진동대 실험을 통해 다음과 같은 결론에 이르렀다. 1) 구조물의 불확실성으로 인한 우발비틀림을 예측하는 것은 정적해석에 의한 방법보다 동적해석에 의한 방법이 더 타당하였다. 2) 횡운동과 비틀림운동이 연관되어 있을 때, 전도모멘트는 지진방향 뿐만 아니라 지진방향에 수직인 방향으로도 상당부분 작용하였으며, 일반적인 해석프로그램에서 수행하는 모드해석법으로는 이와 같은 거동을 예측하기에 부적절하였다. 3) 모드형상과 BST 다이아그램을 통해 대상구조물과 같은 건물의 주요 진동모드와 파괴양상을 쉽게 예측할 수 있었다.