검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 14

        1.
        2021.07 구독 인증기관 무료, 개인회원 유료
        3,000원
        2.
        2021.06 구독 인증기관 무료, 개인회원 유료
        3,000원
        3.
        2021.04 구독 인증기관 무료, 개인회원 유료
        4,000원
        4.
        2021.03 구독 인증기관 무료, 개인회원 유료
        3,000원
        5.
        2021.02 구독 인증기관 무료, 개인회원 유료
        3,000원
        6.
        2016.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Recently, advanced metering infrastructure (AMI) has been recognized as a core technology of smart water grid, and the relevant market is growing constantly. In this study, we developed all-in-one smart water meter of the AMI system, which was installed on the test-bed to verify both effectiveness and field applicability in office building water usage. Developed 15 mm-diameter smart water meter is a magneto-resistive digital meter, and measures flow rate and water quality parameters (temperature, conductivity) simultaneously. As a result of the water usage analysis by installing six smart water meters on various purposes in office building water usage, the water usage in shower room showed the highest values as the 1,870 L/day and 26.6 liter per capita day (LPCD). But, the water usage in laboratory was irregular, depending on the many variables. From the analysis of the water usage based on day of the week, the water usage on Monday showed the highest value, and tended to decrease toward the weekend. According to the PCA results and multivariate statistical approaches, the shower room (Group 3) and 2 floor man’s restroom sink (Group 1-3) have been classified as a separate group, and the others did not show a significant difference in both water use and water quality aspects. From the analysis of water usage measured in this study, the leak or water quality accident did not occur. Consequently, all-in-one smart water meter developed in this study can measure flow rate and water quality parameters (temperature, conductivity) simultaneously with effective field applicability in office building water usage.
        4,000원
        7.
        2006.12 KCI 등재후보 구독 인증기관 무료, 개인회원 유료
        Numerical simulation using computational fluid dynamics (CFD) was performed to calculate the predicted mean vote (PMV) based on velocity and temperature profiles of air in a partitioned office building. The office building (W:14.65 m, D:7.57 m, and H:2.63 m) was divided by partitions of 1.5 m height and shared by 7 office workers. Each person uses a personal computer and printer on a desk. One stand-type air conditioner was installed in the corner of the room and operated at the variable flow rate of 35 ㎥/min. In the case study, we assumed that the initial temperature of the room was 303 K and it was cooled down by operating air-conditioner. The outside temperature was fixed at 303 K and the heat flux through the windows was included in the calculation. Heat sources of personal computers, human bodies, fluorescent lamps, and refrigerator were considered. The temperature and PMV values were also calculated to asses the thermal comfort of each person by operating time of air conditioner. It was found that the thermal comfort could be improved by changing the angle of diffuser grill of air conditioner.
        4,000원
        8.
        2006.09 KCI 등재후보 구독 인증기관 무료, 개인회원 유료
        This research was performed with the subject of 111 offices in a chemical plant of Korea. Airborne concentration level of carbon dioxide, carbon monoxide, formaldehyde and total suspended particulates in the office rooms were measured along with temperature and relative humidity. Simultaneously, general characteristics and subjective health symptoms of 500 office workers were investigated through a questionnaire consisting of the five point weighting method : 0 = not at all, 1 = a little bit, 2 = moderately, 3 = quite a bit and 4 = extremely. Results showed that the mean values for temperature and relative humidity in investigated office rooms were 22.2℃ and 34.3%, respectively. The concentrations of formaldehyde, PM10, carbon dioxide and carbon monoxide were 0.17 ppb, 28.8 ㎍/㎥, 0.95 ppm and 424 ppm, respectively. 56.4% of all the workers investigated replied with a sense of fatigue or weariness (mean=2.23), drowsiness or languidness (mean=2.22), sneezing (mean=2.11) and ophthalmia oreye fatigue (mean=2.07). Female workers, non-smokers, non-drinkers, workers who do shift more than nine hours a day, and workers in poor health experienced more subjective symptoms than other workers (p<0.05). Subjective symptoms of office workers were significantly associated with the following items of office characteristics: the purchase date of office equipment, the change of office furniture, the use of paint, smoking in the office, ventilation condition, the use of an individual air-conditioner, the use of a fax machine, the degree of office repair, the proportion of workers per office, the degree of satisfaction in office environment, and the operation hours of the air-conditioner. Also, subjective symptoms were positively correlated with indoor environmental factors such as relative humidity, carbon dioxide level, level of PM10, and formaldehyde (p<0.05). In conclusion, office characteristics and air quality in a chemical plant affected subjective health symptoms of office workers. Thus, in order to improve the health of workers, to enhance work efficiency, and to establish a better office environment, air quality control in office rooms by optimal ventilation, adequately occupied number of workers in one office, and maintenance of office equipment should be fulfilled thoroughly. keywords:Air quality, Subjective health symptom, Formaldehyde, PM10, Carbon monoxide, Carbon dioxide
        4,300원
        12.
        2000.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        펌프는 다르 진동 유발원들과는 달리 일정한 주파수 및 크기를 갖는 진동을 일으키므로 스프링이나 댐퍼와 같은 간단한 방진기기를 이용하여 진동을 제어할 수 있다 현재 국내에서는 대부분의 펌프에 이러한 방진장치를 설치하는 것이 일반화되어있다 그러나 펌프의 용량 및 중량 주변 구조물의 형태 및 크기 등에 따라서 방진기구의 채택이 불필요한 경우도 있으므로 설비 진동기초에 대한 획일적인 설계와 시공개념은 불필요한 인적, 시간적 및 경제적인 낭비를 초래할 수 있다. 따라서 본 연구에서는 사무용 건무에 사용되는 각종 펌프류에 대하여 가진특성과 구조물의 진동가속도응답을 측정하는 진동실험 및 이론적 해석을 실시하고 본래 계와 수정된 계의 진동을 답과 허용진동수준을 비교.분석함으로서 방진장치의 설치가 불필요한 펌프용량을 제시하였다.
        4,300원
        13.
        1990.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 사무실 적재하중을 체계적으로 조사.수집하여 등가등분하중을 산정하였다. 등가등분포하중은 슬래브, 보 기둥등의 부재별로 영향선을 이용하여 분석하였다. 여기에서 하중효과는 보와 슬래브에서는 휨모멘트, 기둥에서는 축력이 고려되었다. 산정된 등가등분포하중 자료로부터 적재하중의 확률적 특성과 영향면적과의 상관관계가 분석되었으며, 다른 하중조사결과와도 비교되었다. 분석된 적재하중의 확률모형을 이용하여 사용기간 동안의 극한값을 산정하였으며, 이 결과는 현행 설계적재하중과 비교되었다. 또한 보다 합리적인 설계적재하중을 결정할 수 있는 기초자료로서 영향면적에 따른 설게하중식을 제안하였다.
        4,000원
        14.
        2002.03 KCI 등재 서비스 종료(열람 제한)
        Indoor and outdoor nitrogen dioxide (NO2) concentrations were measured and compared with measurements of personal exposures of 95 persons in Seoul, Korea and 57 persons in Brisbane, Australia, respectively. Time activity diary was used to determine the impact on NO2 exposure assessment and microenvironmental model to estimate the personal NO2 exposure. Most people both Seoul and Brisbane spent their times more than 90% of indoor and more than 50% in home, respectively. Personal NO2 exposures were significantly associated with indoor NO2 levels with Pearson coefficient of 0.70 (p<0.01) and outdoor NO2 levels with Pearson coefficient of 0.66 (p<0.01) in Seoul and of 0.51 (p<0.01) and of 0.33 (p<0.05) in Brisbane, respectively. Using microenvironmental model by time weighted average model, personal NO2 exposures were estimated with NO2 measurements in indoor home, indoor office and outdoor home. Estimated NO2 measurements were significantly correlated with measured personal exposures (r = 0.69, p<0.001) in Seoul and in Brisbane (r = 0.66, p<0.001), respectively. Difference between measured and estimated NO2 exposures by multiple regression analysis was explained that NO2 levels in near workplace and other outdoors in Seoul (p = 0.023), and in transportation in Brisbane (p = 0.019) affected the personal NO2 exposures.