Background: The multiple hop test is an active performance test that has been commonly used to assess individuals with functional ankle instability. Previous studies have suggested that insufficiency of dynamic postural stability and passive stability during dynamic activities can have an influence on performance in the multiple hop test. However, no study has investigated the effects of dynamic postural stability training and ankle bracing on multiple hop test performance in individuals with functional ankle instability. Objects: The purpose of this study was to compare the immediate effects of dynamic postural stability training versus ankle bracing in the performance of the multiple hop test for participants with functional ankle instability. Methods: Twenty-nine participants with functional ankle instability who scored below 24 in the Cumberland Ankle Instability Tool were selected. The participants were randomly divided into two groups: a dynamic postural stability training group (n1=14) and an ankle bracing control group (n2=15). The multiple hop tests were performed before and after applying each intervention. Dynamic postural stability training was performed using visual-feedback-based balance-training equipment; participants in this group were asked to perform a heel raise in a standing position while watching the centering of their forefoot pressure to prevent excessive ankle inversion. Ankle bracing was applied in the control group. Results: When comparing the pre- and post-intervention period for both groups, both methods significantly improved the results of the multiple hop test (p<.05). However, no significant differences were shown between the dynamic postural stability training and ankle bracing groups (p>.05). Conclusion: Both dynamic postural stability training and ankle bracing showed significant improvement (2.85 seconds and 2.05 seconds, respectively) in test performance. Further study is needed to determine the long-term effects of dynamic postural stability training and to determine whether insufficient dynamic postural stability is a causative factor for functional ankle instability.
최근 국내에서도 지진의 발생 가능성이 증가하는 추세이며 교량 및 터널 등의 시설물에 대한 지진과 같은 예상하지 못한 작용하중에 대한 안전성을 강화하고 있다. 특히, 1988년 이전 건설된 도시철도 시설물의 대부분은 내진설계가 반영되지 않아 지진하중에 대해 취약할 수 있으므로, 내진안전성에 대한 검토와 보강이 요구되고 있다. 이 연구에서는 도시철도 개착식 터널의 내진성능 향상을 도모하고자, 구조적 취약부분인 내측 기둥에 내진보강을 위한 새로운 FRP-연성재 적층복합체를 제안하였다. 적층조건에 따른 FRP-연성재 적층복합체에 대한 실험을 통해 재료물성치를 산출하여, 이를 근간으로 수치모델을 작성하였다. 수치해석을 통해 제안된 보강재로 보강된 RC기둥의 내진성능이 증대됨을 알 수 있었다. 또한 섬유보강재의 적층조건 (연성재의 종류, FRP 적층수, 섬유배향각)에 따라 성능 향상의 차이가 있는 것을 확인할 수 있었다.