The Moving Particle Semi-implicit (MPS) method is one of most famous method in the particle-based computational fluid dynamics field. The MPS, the state-of-art method, is simple but intuitive methodology including multi-phase and complex structure interactions problems. However, the concept of particle method may contain the physical weakness. In order to avoid physical violence, the particle number density and kernel function were employed. Despite all the efforts, the microscopic problems were not easily resolved yet. In this study, the surface tension model was developed and added into the MPS method to strengthen physical phenomena and physics laws. The simulation result with new MPS method including surface tension model was compared with corresponding theoretical results and they show good-agreement.
이 연구의 목적은 강남 선정릉지역에서 전산유체역학모델(CFD)을 사용하여 도시지역의 흐름 및 열 환경 모의를 검증하는 것이고, CFD 모델의 모의결과와 선정릉 지역의 관측 자료와 비교하는 것이다. CFD 모델은 국립기상과학원과 서울대가 공동으로 연구 개발된 모델이다. CFD_NIMR_SNU 모델은 기상청 현업 모델인 국지예보모델(LDAPS)의 바람성분과 온도성분을 초기 및 경계조건으로 적용되었고 수목효과와 지표 온도를 고려하여 2015년 8월 4일에서 6일까지 강남 선정릉 지역을 대상으로 수치실험을 진행하였다. 선정릉지역에서 수목효과 적용 전후의 풍속을 비교하였을 때 평균 제곱근 오차(RMSE)는 각각 1.06, 0.62 m s−1로 나타났고 수목효과 적용으로 풍속 모의정확도가 향상되었다. 기온은 LDAPS 과소 모의하는 경향을 나타내고 CFD_NIMR_SNU 모델에 의해 향상된 것을 확인하였다. CFD_NIMR_SNU 모델을 이용하여 복잡한 도시지역의 흐름과 열 환경을 자세하고 정밀한 분석이 가능하며, 도시 환경 및 계획에 대한 정보를 제공 할 수 있을 것이다.
This study identified effects of forest density and placed on the fluid flow in the canopy using a computational fluid dynamics model, ENVI_met model. In addition, change of the fluid flow for each point was observed by selecting the impact prediction point. As a result, the density of the forest gave a direct effect on the fluid flow in height below the tree height and inside crown. In case of height below the tree height, the strongest physical changes appeared in CASE1 of dense forest. On the other hand, in case of crown height, distinct fluid flow changes appeared in CASE 2 and 3. After calculating fluid change of the impact prediction point according to altitude, the more dense height below the tree height appear significant changes in the fluid. On the other hand, in case of crown, from the moment outside the interference of the tree, the result showed that the wind path formed distinctly in CASE 2 and 3.
This paper presents the dimensionless wall distance, y+ effect on SST turbulent model for wind turbine blade. The National Renewable Energy Laboratory (NREL) Phase VI wind turbine was used for the study, which the wind tunnel and structural test data has publicly available. The near wall treatment and turbulent characteristics have important role for proper CFD simulation. Most of the CFD development in this area is focused on advanced turbulence model closures including second moment closure models, and so called Low-Reynolds (low-Re) number and two-layer turbulence models. However, in many cases CFD aerodynamic predictions based on these standard models still show a large degree of uncertainty, which can be attributed to the use of the -equation as the turbulence scale equation and the associated limitations of the near wall treatment. The present paper demonstrates the y+ definition effect on SST (Shear Stress Transport) turbulent model with advanced automatic near wall treatment model and Gamma theta transitional model for transition from lamina to turbulent flow using commercial ANSYS-CFX. In all cases the SST model shows to be superior, as it gives more accurate predictions and is less sensitive to grid variations.
With global warming and the rapid increase in urbanization accompanied by a concentration of population, the urban heat island effects (UHI) have become an important environmental issue. In this study, rooftop greening and permeable asphalt pavement were selected as measures to reduce urban heat island and applied to a simple virtual urban environment to simulate temperature change using ENVI-met. A total of five measures were tested by dividing the partial and whole area application of each measure. The results showed that the temperature range of the base experiment is 33.11-37.11 ℃, with the UTCI comfort level described as strong heat and very strong heat stress. A case applied permeable asphalt has a greater temperature difference than a rooftop greening case, the larger the area where each condition was applied, the greater the temperature change was.