검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 8

        4.
        2017.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, thermal performance test of VMD module was performed, prior to the construction of the demonstration plant using the vacuum membrane distillation (VMD) module of the capacity of 400 m3/day and to the commercialization of the VMD module. For the thermal performance test, the experimental equipment of capacity of 2 m3/day was constructed. The permeate flux test and thermal performance test according to feed water conditions such as temperature and flow rate were conducted. The VMD module used in the study was manufactured by ECONITY Co., LTD with PVDF hollow fiber membrane. As a result, the Performance Ratio (PR) of the VMD module showed the maximum value of 0.904 under the condition of feed water temperature of 75℃ and flow rate of 8 m3/h. PR value of the VMD module using PVDF hollow fiber membrane showed linearly increasing relationship with feed water temperature and flow rate. Also, The permeate flux of the VMD module was analyzed to have maximum value of 18.25 LMH and the salt rejection was 99.99%.
        4,000원
        5.
        2017.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Scale formation is inevitable problem when seawater is treated by vacuum membrane distillation. The reason is the high concentration of calcium ion(Ca2+), sulfate ion(SO4 2-) and bicarbonate ion(HCO3 -). These ions form calcium sulfate(CaSO4) and calcium carbonate(CaCO3) on the membrane. The scale formed on membrane has to be removed, because the flux can be severely reduced and membrane wetting can be incurred. This study was carried out to investigate scale formation and effectiveness of acid cleaning in vacuum membrane distillation for SWRO brine treatment. It was found that permeate flux gradually declined until volume concentration factor(VCF) reached around 1.55 and membrane wetting started over VCF over 1.6 in the formation of precipitates containing CaSO4 during VMD operation. In contrast, when calcium carbonate formed on membrane, permeate flux was gradually reduced until VCF 3.0. The precipitates containing both CaSO4 and CaCO3 were formed on the membrane surface and in the membrane pore.
        4,000원
        6.
        2016.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, the performance experiment was conducted to compare the permeate flux of hollow fiber Vacuum Membrane Distillation module according to leak problem between module housing and membrane bundle. For the permeate flux performance experiment of the two Vacuum Membrane Distillation modules, the Lab-scale experimental equipment was built in the capacity of 1㎥/day. The performance test of the two Vacuum Membrane Distillation modules were analyzed according to the feed water conditions. As a result, it was analyzed that the leak VMD module decreased about 14% of permeate flux than normal VMD module.
        4,000원
        7.
        2014.09 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        파이로 공정은 사용후핵연료 관리 이슈 해결과 유용자원 재활용 제고의 목적으로 개발되고 있다. 파이로 공정 중 전해환원 공정은 LiCl을 전해질로 사용하여 산화물을 금속으로 전환시키는 공정으로 금속 전환체에 잔류염이 포함되므로 후속 공정이 요구된다. 진공 증류 공정은 다양한 용융염계에서 적용되어 왔으며 금속 전환체에서도 활용될 수 있다. 전해환원 금속 전환 체 잔류염은 LiCl과 알카리 및 알카리토 금속 염화물을 포함한다. 본 연구에서는 이들 염화물들의 증기압을 추산하여 진공 증 류 공정에서 잔류 액체의 조성변화를 계산하였다. 증류된 기체가 일정하게 제거되는 조건에서 물질수지와 기-액 평형식을 결 합한 모델을 개발하였으며 증기압을 이용하여 무차원 시간에 대한 액체 조성 변화를 계산하였다. 공정 조건 변화 모사를 위 해 온도와 용융염 조성을 변화시켜 거동을 비교하였다. 잔류염의 증류는 주성분인 LiCl에 의해 지배되었으며 LiCl 보다 증기 압이 높은 CsCl은 쉽게 제거될 것이 예상되었다. 증기압이 유사한 RbCl은 LiCl과 일정한 조성이 유지되었다. 반면 증기압이 낮은 SrCl2와 BaCl2는 시간에 따라 농축되며 초기 조성이 높은 경우 증류 과정에서 석출될 가능성이 있는 것으로 예상되었다.
        4,200원