검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 6

        3.
        2016.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Development of shale gas has drawn increasing attention since it is one of promising alternative energy resources. However, contamination of groundwater and surface water during the extraction of shale gas is becoming a serious environmental issues, which brings the needs to treat wastewater generated from hydraulic fracking. In this study, the feasibility of membrane distillation (MD) for the treatment of shale gas wastewater was investigated using a laboratory scale experimental setup. Flat-sheet MD membranes were used to treat produced water from a shale gas well in the United States. Different configurations such as direct contact MD (DCMD) and air gap MD (AGMD) were compared in terms of flux and fouling propensity. The foulants on the surface of the membranes were examined. The results suggest that MD can treat the shale gas produced water containing more than 200,000 mg/L of total dissolved solids, which is impossible by other technologies such as reverse osmosis (RO) and forward osmosis (FO). In this study, we investigated the possibility of processing and characterization of shale gas produce wastewater using membrane distillation. Laboratory scale membrane distillation experimental device was developed. It was compared the flat-sheet direct contact membrane distillation and flat-sheet air gap membrane distillation. AGMD flux in lower than the flux of DCMD, it was expected that the contamination caused by organic matters.
        4,000원
        4.
        2016.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 하수처리수를 원수로 사용하여 직접 접촉식 막증발법을 적용하여 원수 온도와 원수 유량 변화에 따 른 하수처리수의 COD, TN, TP, TOC의 제거율 변화와 여과플럭스의 변화를 측정하였다. 또한 하수처리수에 의한 분리막의 오염 가역성을 평가하기 위해 1차 증류수만을 사용하여 물리세정을 수행한 후 플럭스의 회복률을 측정하였다. 실험결과 원수 의 온도 및 유량에 관계없이 원수가 3배 농축될 때까지 여과를 진행하였음에도 불구하고 하수처리수의 주요 오염물질인 COD, TN, TP, TOC에 대한 제거율이 92% 이상으로 높게 나타났다. 또한 비교적 낮은 온도인 50°C와 60°C에서 원수의 유량에 따라 최소 13.8 LMH에서 20.3 LMH로 높은 여과플럭스를 나타냈다. 그리고 높은 농축계수까지 여과 실험을 진행했음에도 불구하 고 낮은 여과플럭스의 감소를 나타냈으며 1차 증류수를 이용한 짧은 시간 동안의 물리세정만으로 최소 90% 이상의 높은 여과 플럭스 회복율을 나타냈다. 따라서 하수처리수 재이용을 위한 공정으로 막증발법의 적용이 충분히 가능할 것으로 판단된다.
        4,000원
        5.
        2015.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        A combined treatment system using multiple source water is becoming important as an alternative to conventional water supply for small-scale water systems. In this research, combined water treatment systems were investigated for simultaneous use of multi-source water including rainwater, ground water, river water, and reclaimed wastewater. A laboratory-scale system was developed to systematically compare various combinations of water treatment processes, including sand filtration, microfiltration (MF), granular activated carbon (GAC), and nanofiltration (NF). Results showed that the efficiency of combined water treatment systems was affected by the quality of feed waters. In addition, a simply approach based on the concept of linear combination was suggested to support a decision-making for the optimum water treatment systems with the consideration of final water quality.
        4,000원
        6.
        2014.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        지붕이나 여러 가지 방법과 장소에서 수집된 빗물을 처리하면 직접적 간접적으로 유익하게 사용될 수 있다. 이러한 빗물은 점점 더 높은 품질을 위해 고려되고 있고, 분리막은 이러한 빗물 처리를 위한 중요한 기술이다. 특히, 분리막은 고품질 물 생산, 높은 집적도 및 낮은 에너지 소비 등의 장점이 있다. 그럼에도 불구하고, 막오염은 수처리 및 폐수 재활용 부분과 마찬가지로 심각한 문제로 간주되고 있다. 본 연구에서는 빗물 처리에 정밀여과(MF)막을 적용하였고, 저압 자외선(LPUV)처리를 정밀여과막의 전처리로 사용하였다. 유기물에 대한 UV의 영향을 정량화하기 위해 총 유기탄소(TOC) 및 UV 흡광도(UVA)를 모두 측정하였다. 또한 UV 전처리 효과에 따른 막의 오염 정도를 조사하였다. LPUV 전처리를 하고 실험을 한 결과 조류에 의해 오염된 빗물에서 막의 오염을 제어하는데 효과적임을 알 수 있었으며, 이것은 UV 처리 후 유기물의 양이 감소하고 특성이 변화하기 때문이었다. 따라서 UV/MF 처리는 마이크로 워터 그리드 시스템과 같은 수처리를 위한 유망한 옵션이 될 수 있을 것으로 생각된다.
        4,000원