검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 27

        1.
        2020.01 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In 2016, an earthquake occurred at Gyeongju, Korea. At the Wolsong site, the observed peak ground acceleration was lower than the operating basis earthquake (OBE) level of Wolsong nuclear power plant. However, the measured spectral acceleration value exceeded the spectral acceleration of the operating-basis earthquake (OBE) level in some sections of the response spectrum, resulting in a manual shutdown of the nuclear power plant. Analysis of the response spectra shape of the Gyeongju earthquake motion showed that the high-frequency components are stronger than the response spectra shape used in nuclear power plant design. Therefore, the seismic performance evaluation of structures and equipment of nuclear power plants should be made to reflect the characteristics of site-specific earthquakes. In general, the floor response spectrum shape at the installation site or the generalized response spectrum shape is used for the seismic performance evaluation of structures and equipment. In this study, a generalized response spectrum shape is proposed for seismic performance evaluation of structures and equipment for nuclear power plants. The proposed response spectrum shape reflects the characteristics of earthquake motion in Korea through earthquake hazard analysis, and it can be applied to structures and equipment at various locations.
        4,000원
        3.
        2018.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        A base isolation system is widely used to reduce seismic responses of low-rise buildings. This system cannot be effectively applied to high-rise buildings because the initial stiffness of the high-rise building with the base isolation system maintains almost the same as the building without the base isolation system to set the yield shear force of the base isolation system larger than the design wind load. To solve this problem, the mid-story isolation system was proposed and applied to many buildings. The mid-story isolation system has two major objectives; first to reduce peak story drift and second to reduce peak drift of the isolation story. Usually, these two objectives are in conflict. In this study, a hybrid mid-story isolation system for a tall building is proposed. A MR (magnetorheological) damper was used to develop the hybrid mid-story isolation system. An existing building with mid-story isolation system, that is “Shiodome Sumitomo Building” a high rise building having a large atrium in the lower levels, was used for control performance evaluation of the hybrid mid-story isolation system. Fuzzy logic controller and genetic algorithm were used to develop the control algorithm for the hybrid mid-story isolation system. It can be seen from analytical results that the hybrid mid-story isolation system can provide better control performance than the ordinary mid-story isolation system and the design process developed in this study is useful for preliminary design of the hybrid mid-story isolation system for a tall building.
        4,000원
        4.
        2018.01 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, we conducted a shake table test to verify the seismic performance of the paneling system with steel truss composed of bolt connections. The control group was set to the traditional paneling system with steel truss connected by spot welding method. Test results showed that the bolted connection type paneling system has excellent deformation capacity without cracking or brittle fracture of the steel truss connection parts compared to the welding type paneling system. Furthermore, in the bolted connection type, slight damage occurred at the time of occurrence of the same story drift angle as compared with the existing method, it is considered that it has excellent seismic performance. In compliance with the performance-based design recommended for the current code (ASCE 41-13) on non-structural components, it is judged that in the case of the bolted connection type paneling system, it can be applied to all risk category structures without restriction. However, in the case of traditional paneling system with spot welding method, it is considered that it can be applied limitedly.
        4,000원
        5.
        2016.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        It has been many efforts for reinforcement of existing structure since the number of earthquake has been increased world widely. Especially the occurrence of earthquake surrounding area of Korean peninsular is dramatically increased. Since the buildings in Korea have not been designed to carry the lateral and shear force caused by earthquake, the building will experience massive damages even under moderate earthquake. For this reason, the viscoelastic damper is proposed in this paper to enhance the earthquake resistance of a steel frame buildings. The viscoelastic dampers have been able to increase the overall damping of the structure significantly, hence improving the overall performance of dynamically sensitive structures. In this paper, Viscoelastic dampers designed are consists of FRP panel and viscoelastic material. In this paper, evaluate the performance of the viscoelastic damper through the experiment.
        4,000원
        6.
        2015.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Damped outrigger systems have been proposed as a novel energy dissipation system to protect tall buildings from severe earthquakes and strong wind loads. In this study, semi-active damping devices such as magnetorheological (MR) dampers instead of passive dampers are installed vertically between the outrigger and perimeter columns to achieve large and adaptable energy dissipation. Control performance of semi-active outrigger damper system mainly depends on the control algorithm. Fuzzy logic control algorithm was used to generate command voltage sent to MR damper. Genetic algorithm was used to optimize the fuzzy logic controller. An artificial earthquake load was generated for numerical simulation. A simplified numerical model of damped outrigger system was developed. Based on numerical analyses, it has been shown that the semi-active damped outrigger system can effectively reduce both displacement and acceleration responses of the tall building in comparison with a passive outrigger damper system.
        4,000원
        7.
        2015.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Recently, the concept of damped outrigger system has been proposed for tall buildings. But, structural characteristics and design method of this system were not sufficiently investigated to date. In this study, the dynamic response control performance of outrigger damper has been analyzed. To this end, a simplified analysis model with outrigger damper system has been developed. An artificial wind of 1000 seconds with 0.1 second time steps was generated by using a Kaimal spectrum. Analysis results show that outrigger damper system is more effective up to 20-23% in the control of dynamic response compared to conventional outrigger system. The increase of outrigger damper capacity usually results in the improved control performance. However, it is necessary to select that proper stiffness and damping values of the outrigger damper system because, the outrigger damper having large capacity is result in heavy financial burden.
        4,000원
        8.
        2013.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, an externally reinforced structural system for SMC(Sheet Molding Compound) panel water tank, designed according to the Japanese design code, is experimented to evaluate its seismic performance. The test tank is 3m long, 2m wide and 3m high, considering the capacity and size of the shaking table. The measured hydrodynamic pressures are found to be approximately 70% of the Japanese design code values. It may be partially due to the convex shape effect of the unit panels. The analytical results of externally reinforced system based on the measured dynamic water pressures are found in good agreement with the test results. If the design hydrodynamic pressures are estimated properly, the proposed analytical model for the externally reinforced water tank becomes a useful design tool and the Japanese design code is found to provide a safe design for the external frames of SMC panel water tank.
        4,000원
        9.
        2010.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 지진시 앵커기초의 파괴한계성능을 평가하기 위하여 진동대 실험을 수행하였다. 앵커기초에 발생 가능한 열화현상인 균열의 영향을 평가하기 위하여 균열이 없는 시편, 관통균열 시편 그리고 파괴예상면 내에 측면균열이 있는 시편을 제작하여 각각의 파괴한계성능을 평가하였다. 우선적으로 임팩트 해머에 의한 가진 실험을 통하여 동특성분석실험을 수행하여 실험모형의 동특성을 분석하였으며, 앵커기초의 파괴 시까지 진동대 실험을 수행하여 극한거동을 평가하였다. 최종적으로 앵커기초의 설계기준과 비교하여 거동특성을 분석하였다.
        4,000원
        10.
        2010.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 스카이브릿지 설치위치 및 연결된 구조물의 고유진동주기 차이에 따른 전체 구조물의 진동제어 효과를 분석하였다. 이를 위하여 스카이브릿지로 연결된 40층과 50층 구조물을 예제 구조물로 사용하였고, 등가모형화기법을 이용하여 예제 모델을 구성하였다. El Centro 및 Taft 지진을 사용하여 경계비선형 시간이력해석을 수행하였고 구조물의 동적거동과 진동제어 효과를 분석하였다. 해석결과 변위응답은 스카이브릿지를 상부층에 설치할수록 더 효과적으로 제어할 수 있었고 가속도응답은 구조물의 중간층부근에 설치할 때 더 효과적으로 저감시킬 수 있었다.
        4,000원
        11.
        2010.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 스마트 최상층 면진시스템을 적용한 고층건물의 풍응답 제어성능을 검토해보았다. 이를 위하여 77층 초고층 건물을 예제구조물로 선택하였고 풍동실험을 통해서 얻은 풍하중을 사용하여 수치해석을 수행하였다. 예제구조물의 최상층은 FPS 및 MR 감쇠기로 구성된 스마트 면진시스템을 이용하여 주구조물과 분리된다. 주구조물의 동적응답을 저감시키는 것이 스마트 최상층 면진시스템의 가장 중요한 목표이지만 면진된 최상층의 과도한 응답은 구조물을 불안정하게 만들 수 있다. 따라서, 본 연구에서는 면진된 최상층과 주구조물을 효과적으로 제어하기 위하여 스카이훅제어기를 제어알고리즘으로 사용하였다. 제안된 스마트 최상층 면진시스템의 제어성능을 검토하기 위하여 일반적인 수동 최상층 면진시스템의 제어성능과 비교하였다. 수치해석결과 제안된 스마트 최상층 면진시스템을 이용하면 일반적인 수동 최상층 면진시스템에 비해서 면진층의 변위를 효과적으로 줄이면서도 구조물의 응답을 저감시킬 수 있음을 확인할 수 있었다.
        4,000원
        12.
        2009.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        2방향 중공슬래브 시스템은 슬래브 두께가 증가해도 자중은 크게 증가하지 않으면서 솔리드 슬래브에 비해서 휨강성이 크게 저하되지 않는 장점이 있다. 따라서 최근 넓은 바닥판 구조에 대한 수요가 커지면서 2방향 중공슬래브 시스템에 대한 관심이 증가하고 있다. 그러나 이러한 장스팬 구조의 경우 바닥판 진동의 증가에 의한 사용성에 문제가 발생할 수 있고 특히 2방향 중공슬래브의 경우 기존의 구조시스템과 동적특성이 상이하다. 따라서 본 연구에서는 기존의 라멘조 시스템과 2방향 중공슬래브 시스템의 바닥진동성능을 보행하중을 가하여 검토해 보았다. 본 연구에서는 해석의 효율성을 위하여 2방향 중공슬래브의 동적특성을 정확히 나타낼 수 있는 등가의 플레이트 모델을 사용하여 시간이력해석을 수행하였다. 해석결과를 바탕으로 일본건축학회와 미국표준협회에서 제안하는 진동성능평가 기준을 이용하여 진동성능 평가를 수행한 결과 2방향 중공슬래브가 사무실 수준의 진동성능을 만족하고 있는 것으로 나타났다.
        4,200원
        13.
        2008.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 sky-bridge로 연결된 고층건물의 진동제어성능을 검토하여 보았다. Sky-bridge를 이용한 진동제어의 원리는 서로 다른 동적특성을 가진 구조물이 sky-bridge를 통하여 제어력을 발휘함으로써 전체 시스템의 응답을 줄이는 것이다. 본 연구에서는 실제 건설 중인 sky-bridge로 연결된 고층건물(49층 및 42층)을 대상으로 구조물의 변위, 가속도 및 베어링반력, sky-bridge의 응력 등을 해석적인 방법으로 검토하였다. 이를 위하여 역사지진, 인공지진 및 풍동실험을 통해서 얻은 풍하중 시간이력을 사용하였다. 해석결과 sky-bridge를 사용하여 고층건물의 풍응답 및 지진응답을 효과적으로 줄일 수 있는 것을 확인하였다.
        4,000원
        14.
        2007.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        합성 교각의 설계에서 요구 내진성능을 만족하기 위한 철근상세 규정이 명확하지 않은 측면이 있다. 합성 교각은 단면치수를 감소시키고 지진하중하에서 기둥의 연성을 개선하기 위해 제안되었다. 이 논문에서는 400mm 직경을 가진 단일 강재를 콘크리트에 매입한 합성기둥 부재를 5기 제작하여 합성기둥의 내진성능을 연구하였다. 진동대 실험과 유사동적 실험이 수행되었는데 근단층지반운동을 고려한 축소모형의 구조적 거동이 평가되었다. 실험 변수는 횡철근의 간격, 주철근의 겹침이음, 매입 강재 단면으로 설정하였다. 진동대 실험에 의해 평가된 변위연성도가 유사동적 실험에 비해 적게 나타났고 한정연성설계, 주철근의 겹침 이음 50%를 가진 부재가 기준 부재에 비해서 낮은 연성도를 보였다. 강재비는 극한강도에 영향을 미치고 겹침이음과 횡철근 비의 감소는 변위능력을 감소시켰다. 합성 교각의 상세에 따른 에너지 소산능력의 차이는 뚜렷하게 나타나지 않았다.
        4,200원
        15.
        2006.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        지진과 같은 재난이 발생하였을 때에도 전력설비는 그 본래의 기능을 상실하지 않고 구조적인 안정성을 유지해야 하는 핵심 산업시설물이다. 이 연구는 가장 대표적인 전력설비인 154kV 변압기에 부착된 애자형 부싱의 진동특성과 내진성능을 분석하였다. 연구의 목적에 따라 국내에서 운용하던 실제 154kV 변압기 부싱을 대상으로 30tonf 용량의 진동대를 이용하여 진동시험이 실시되었다. 진동시험은 동특성분석시험과 내진성능시험 그리고 파괴한도시험으로 구분하고, 각각의 시험에는 정현소인파, 인공지진파 그리고 연속공진정현파를 진동대운동으로 입력하였다. 이 논문에는 시험에 사용된 시편과 진동설비의 특성 그리고, 시험 방법 및 종류를 설명하고, 시험 결과 얻어진 계측자료의 특성에 대하여 논의한다. 이 연구를 통하여 국내에서 운용중인 154kV 변압기 부싱은 그 고유진동수가 20Hz 이상인 고진동수 설비이며, 감쇠비는 4%미만인 것으로 분석되었다. 또한, 특별한 경우를 제외하고, 변압기 부싱은 국내의 설계기준지진에 대하여 충분한 내진안전성을 보유하고 있으며, 강한 공진운동에 의해 예상되는 부싱의 최초 파괴모드는 하단 개스킷의 파손인 것으로 밝혀졌다.
        4,000원
        16.
        2019.04 서비스 종료(열람 제한)
        Recently many investigations have been conducted to evaluate and analyze the seismic response of structures equipped different types of damper. Viscous dampers are known as effective energy dissipation devices improving structural response to earthquakes. The damping force developed by the viscous damper depends on internal structural system and the physical properties of the fluid used in the device. This study has developed a viscous damper for vibration and seismic control of structures. In order to verify the performance of a viscous damper, experimental tests were performed.
        17.
        2017.10 KCI 등재 서비스 종료(열람 제한)
        소음 저감을 목적으로 설치되는 방음벽은 크게 흡음판과 방음판으로 나뉘며, 일조 및 경관을 저해하는 방음벽의 문제점을 해결하 고자 투명 방음벽을 설치하는 것이 일반적 추세이다. 방음벽에 사용되는 투명 방음판의 소재는 여러 가지가 있으나 경우에 따라서는 황변현상 과 재질변형 등으로 인해 투명도가 떨어지고 오염이 심해져 오히려 도시미관을 해하기도 한다. 따라서 이러한 단점을 보안하기 위하여 투명 방 음판의 재질을 접합강화유리로의 대체가 가능하다. 본 논문은 메트로 지하철 고가교 상에서의 열차 유발진동에 따른 접합강화유리 방음판의 진동 및 풍하중에 의한 안전성을 분석하고, 접합강화유리 시스템 및 재료에 대한 휨능력 성능시험, 압축강도 및 탄성계수 시험, 충격시험 등을 수행하여 접합강화유리의 방음판으로서의 적정성을 평가하는 데 목적이 있다.
        18.
        2017.09 서비스 종료(열람 제한)
        In this study, the shake table tests were performed for seismic performance evaluation of fire protection riser pipes. The specimen was subjected to a tri-axial time history shake table test with acceleration levels corresponding to the 0.5g and 0.7g ZPA design level.
        19.
        2017.05 KCI 등재 서비스 종료(열람 제한)
        장스팬 구조물은 사용하중 하에서 바닥진동 문제가 발생할 가능성이 크다. 따라서 구조물 바닥판의 진동성능을 향상시키기 위한 가장 일반적인 방법은 슬래브의 두께를 증가시키는 것이지만 기존의 구조시스템에서 슬래브의 두께를 증가시키면 슬래브 자중의 증가로 건축 물 전체의 효율성이 떨어지게 되는 문제점이 있다. 따라서 슬래브의 두께를 증가시키면서도 자중은 크게 증가하지 않는 바닥판 시스템으로 중 공슬래브에 관한 관심이 커지고 있는 상황이다. 이에 부력방지능력 및 시공성 향상을 위하여 데크플레이트와 경량성형재를 결합한 형태의 중 공슬래브를 개발하였고, 이 중공슬래브를 적용한 실물(mock-up) 건축물에 대한 사용성 검증을 위한 진동성능 평가를 수행하였다. 측정된 결과값을 분석한 결과, 일본건축학회의 “건축물의 진동에 관한 거주 성능 평가지침”에 의하면 1등급인 거실, 침실에 사용해도 될 수준 으로 평가되었다.
        20.
        2016.05 KCI 등재 서비스 종료(열람 제한)
        이 연구에서는 SC 전단벽의 전단 연결재인 스터드의 배치와 형상이 SC 전단벽의 거동에 미치는 영향을 살펴보기 위해 전단벽체가 강제진동을 받을 때의 거동을 해석적으로 검토하였다. 이를 위해 서로 다른 배치간격과 형상의 스터드가 배열된 SC 전단벽을 대상으로 유한요 소해석을 수행하였다. 그 결과, 시간이력해석으로부터 구한 감쇠비가 파워반감대역폭법이 전반적으로 높게 그리고 적합지수함수법이 가장 낮은 수준으로 산정했으며 설계강도 절반정도에서의 감쇠비는 3.0~4.2%로, 설계강도에서는 4.1~5.2%로 나타남을 알 수 있었다. 또한, 개선된 스터드를 사용할 때, 감쇠비가 약간 감소하였고 DS1과 DS2 간에는 일관된 결과가 나타나지 않았다. 스터드의 간격이 필요이상 증가할 경우, 고유진동수가 감소하고 감쇠비가 증가함을 확인하였다.
        1 2