제22권 제1호 (통권 제120호) (2018년 1월) 4

1.
2018.01 구독 인증기관 무료, 개인회원 유료
In this study, we develop and propose damping correction factors for the Korean standard design spectra. The newly proposed Korean standard design spectra has been given only for 5% damping ratio. But in practice, engineers need design spectra for damping values other than 5%. To obtain design spectra for various damping values from the standard spectra, damping correction factors are derived. These factors modify the shape of design spectra in accordance with the damping ratio. Response spectra for various damping values are calculated from the earthquake records that had been used to calculate standard design spectra. They consist of 55 records from 18 earthquakes occurred in overseas intraplate regions and Korea. The regressed spectra for the damping values ranging from 0.5% to 50% are compared with standard spectra at three regions acceleration, velocity and displacement sensitive regions. The regression analysis of these data rendered formula for damping correction factors. Finally, a single formula for damping correction factors is recommended that is valid for both horizontal and vertical design spectra and that is applicable to the entire range of periods. One thing to note that recommended damping correction factors is valid for the design spectrum of the rock grounds because the design spectra was developed based on the earthquake records of the rock ground.
4,600원
2.
2018.01 구독 인증기관 무료, 개인회원 유료
Pseudo-static approach has been conventionally applied for the design of gravity type quay walls. In this method, seismic coefficient (kh), expressed in terms of acceleration due to gravity, is used to convert the real dynamic behavior to an equivalent pseudo-static inertial force for seismic analysis and design. Therefore, the calculation of an appropriate kh considering frequency characteristics of input earthquake is critical for representing the real dynamic behavior. However, the definitions of kh, which is used for simplified analysis in Korea, focuses only on convenience that is easy to use, and the frequency characteristics of input earthquake are not reflected in the kh definitions. This paper evaluates the influences of the frequency characteristics of input earthquake on kh by initially reviewing the kh definitions in the existing codes of Japan for port structures and then by performing a series of dynamic centrifuge tests on caisson gravity quay walls of different earthquake input motions (Ofunato, Hachinohe). A review of the existing codes and guidelines has shown that the kh values are differently estimated according to the frequency characteristics of input earthquake. On the other hand, based on the centrifuge tests, it was found that the permanent displacements of wall are more induced when long-period-dominant earthquake is applied.
4,000원
3.
2018.01 구독 인증기관 무료, 개인회원 유료
In this study, we conducted a shake table test to verify the seismic performance of the paneling system with steel truss composed of bolt connections. The control group was set to the traditional paneling system with steel truss connected by spot welding method. Test results showed that the bolted connection type paneling system has excellent deformation capacity without cracking or brittle fracture of the steel truss connection parts compared to the welding type paneling system. Furthermore, in the bolted connection type, slight damage occurred at the time of occurrence of the same story drift angle as compared with the existing method, it is considered that it has excellent seismic performance. In compliance with the performance-based design recommended for the current code (ASCE 41-13) on non-structural components, it is judged that in the case of the bolted connection type paneling system, it can be applied to all risk category structures without restriction. However, in the case of traditional paneling system with spot welding method, it is considered that it can be applied limitedly.
4,000원
4.
2018.01 구독 인증기관 무료, 개인회원 유료
‘Seismic Performance Evaluation Method for Existing Buildings (2013)’ developed in accordance with the overseas guidelines ASCE 41 - 06 is the most widely used procedure among domestic seismic performance evaluation guidelines in Korea. However, unlike ASCE 41 - 06, it stipulates that the final performance should be derived as the gravity load distribution ratio of the lateral force resistance system in the guideline. Therefore, in the case of a dual steel structure system with slender braces, where the internal moment frame is mostly responsible for the gravity load, the evaluation of slender braces based on gravity load distribution ratio is difficult to be achieved. In this research, we propose an objective evaluation process for such system by evaluating seismic performance for large-scale factory facilities as an example.