In this study, we conducted a shake table test to verify the seismic performance of the paneling system with steel truss composed of bolt connections. The control group was set to the traditional paneling system with steel truss connected by spot welding method. Test results showed that the bolted connection type paneling system has excellent deformation capacity without cracking or brittle fracture of the steel truss connection parts compared to the welding type paneling system. Furthermore, in the bolted connection type, slight damage occurred at the time of occurrence of the same story drift angle as compared with the existing method, it is considered that it has excellent seismic performance. In compliance with the performance-based design recommended for the current code (ASCE 41-13) on non-structural components, it is judged that in the case of the bolted connection type paneling system, it can be applied to all risk category structures without restriction. However, in the case of traditional paneling system with spot welding method, it is considered that it can be applied limitedly.
국내의 폐기물 발생량은 2013년 기준 약 1억 4천만톤이고, 이중 소각처리된 폐기물은 약 8백만톤으로 6%정도로 나타났다. 많은 연구를 통해 비산재의 재활용률은 80%에 이르렀으나, 바닥재의 경우 일부를 제외한 대부분이 매립되고 있는 실정이다. 본 연구에서는 폐기물 소각 시 발생하는 소각재중 바닥재의 건설재료로서 재활용가능성을 평가하기 위해 기본물성 및 역학시험을 수행하였다. 국내 3곳의 생활폐기물 소각장에서 발생된 바닥재를 채취하여 소각방식에 따라 화격자 소각방식으로 처리하는 소각장에서 채취된 바닥재를 시료 A, B로 분류하고 열분해 용융방식으로 소각된 바닥재를 시료 C로 구분하였다. 시료의 화학적 조성을 분석하기 위해 XRF 분석을 실시하였다. 성분분석결과 일반적인 조립질 지반과 비교하여 SiO2 함량이 낮고, CaO 함량이 높은 것으로 나타남에 따라 바닥재를 다른 재료와 혼합하는 경우 화학반응에 대한 영향을 고려해야 한다. 체가름 시험, 비중시험, 상대밀도시험을 실시하여 물리적 특성을 파악하였으며, 역학적 특성을 분석하기 위해 투수시험, 다짐시험, 직접전단시험을 실시하였다. 각 시험에서 도출된 결과는 표 1에 정리하였다. 생활폐기물 소각 바닥재는 통일분류법에 의해 양입도(A, C 시료)와 빈입도(C 시료)의 모래로 분류되는데 사질토와 유사한 경향을 보인다. 비중의 경우 일반 모래(2.6~2.8)와 비교하여 열분해용융 소각방식에서 큰 비중을 가지는 것으로 나타나는데, 이는 고온에서 용융된 슬래그(바닥재)의 영향 때문인 것으로 판단된다. 투수계수는 일반적인 사질토의 범위에 속하며, C 바닥재가 약 15배 이상 투수성이 큰 것으로 나타나 유효입경의 크기에 따른 영향보다는 소각방식에 따른 입자의 형상 및 간극의 분포에 의한 영향을 받는 것으로 판단된다. 바닥재의 다짐특성은 일반적인 조립토의 경향과 일치하며, A 및 B 시료와 비교하여 C 시료의 최대건조단위중량이 크고 최적함수비는 작은 경향을 보인다. 바닥재의 강도특성은 일반적인 사질토와는 다른 경향을 나타내는데, 이는 소각방식의 영향과 원 재료가 가지고 있던 물리적 특성의 복합적인 요인에 의한 차이로 판단된다.
In this study, Long-period component seismic wave is determined to a large damage of the non-structural material as compared to the structure damage when it is input to high-rise buildings, which allows to perform a vibration table test, was evaluated for damage or loss of the non-structural material.
In this study, subject to the new shape vibration damping system that can be reused, it performed response analysis. It have developed the analysis model which can be effectively reflect the structural properties of the damping system is verified through the analysis and experimental results of existing. And it analyzed the response characteristics of the developed damping system through the analysis result.
In this study, strain distribution of the beam end and the end of horizontal stiffener of high-strength steel beam-to-column connections was analyzed by finite element methods. According to the FEM results, applied stiffener method showed that it is available to relieve the strain of maximum stress point of beam member
In this strudy, it establish nonlinear finite element analysis for beam-to-column connections constituted high strength steel beam and general mild steel beam. it analyze major structural performance of connections according to stiffness and strength of both-way beams and it consider the structural problem of application of high strength steel beam through the analysis results.
To evaluate the ductility of high strength steel beam-to-column connections, Cycle loading connection test was conducted targeting HSA800 steel being developed in Korea and parameter is connection details. According to the study, The non-scallop detail and improved horizontal rib reinforcement detail used in this study enhanced deformation capacity of high strength steel connections which have brittle tendency by stress relaxation.
본 연구는 한국 축구심판들이 심판수행 과정에서 유발되는 판정실책 원인과 한 경기에서 경험하는 판정실책 횟수, 판정실책 시간대, 경기규칙 숙지도, 판정실책을 한 후 그 실책이 다음 판정에 어떤 영향을 주는지를 분석하기 위해 한국 축구심판 1급 심판 40명, 2급 심판 40명, 3급 심판 40명 총 120명을 대상으로 개방질문지를 사용하여 분석한 결과, 1) 축구심판들이 심판수행 과정에서 경험하는 판정실책 원인은 신체적요인, 심리적 요인, 인지적 요인, 환경적 요인, 경험적 요인 5개 영역으로 나타났다. 2) 한 경기에서 판정실책 횟수는 1급 심판 2회, 2급 심판 3회, 3급 심판 4회, 전체 평균은 4회로 나타났다. 3) 축구심판들의 판정실책 시간대는 1급 심판은 후반 종료 10분전에, 2급 심판은 전?후반 10분 사이에, 3급 심판은 전?후반 10분에서 후반 20분 사이에, 전체 심판은 후반 종료 10분전에 가장 많이 판정실책을 경험하는 것으로 나타났다. 4) 축구심판들의 경기규칙 숙지도는 1급, 2급 심판은 90%이상, 3급 심판은 70-89%가 가장 높게 나타났고, 2급 심판에서 70-89%가 2번째로 높게 나타났다. 5) 경기 중 판정실책이 있은 후 다음 판정에 미치는 영향을 조사한 결과, 1급 심판은 초지일관 처음과 같이 판정하며, 2급과 3급 심판은 그 후 판정기준의 흔들림을 느끼어 판정실책을 경험한다고 하였다. 결국 축구 심판들의 판정실책이 유발되는 원인은 심리적 요인으로 인한 판정실책이 가장 많이 조사되었다. 따라서 축구 심판들의 심판수행 능력을 향상시키기 위해서는 신체적인 훈련 뿐 만 아니라 정규적인 심리훈련과 심리적인 문제를 해결할 수 있도록 하여야할 것이다.
축구경기에서 승부차기 시 선수들은 킥 기술 외 환경적·상황적 요인에 따라 다양한 심리적 갈등을 경험한다. 본 연구는 축구선수들이 승부차기 시 경험하는 킥 선호순위, 습관요인, 방해요인과 그에 따른 대처요인을 규명하는 데 그 목적이 있다. 이를 위해 초·중·고 각 5개 학교의 축구선수 총 300명을 대상으로 선택형 질문과 개방질문지를 사용하였다. 그 분석 결과, 첫째, 승부차기 시 싫어하는 킥의 순서는 1번과 5번 그리고 좋아하는 순서는 2번과 3번으로 나타났다. 둘째, 승부차기 시 갖는 습관요인은 방향설정, 징크스 행동, 골키퍼 견제, 호흡, 발걸음 수 공식화, 기도, 기타 7개 영역으로 나타났다. 특히 방향 설정에 대한 습관은 "차는 쪽 반대쪽을 쳐다본다"가 가장 높은 빈도를 보였으며, 중·고 축구선수들은 "심호흡을 크게 한다"와 같은 호흡과 관련된 습관요인이 높은 빈도를 나타냈다. 여기서 축구선수들의 습관요인 중 골키퍼에게 킥의 방향을 예측할 수 있는 단서를 제공하는 습관이 있음이 발견되었다. 셋째, 승부차기 시 경험하는 방해요인은 실패 및 실수에 대한 걱정, 방향 설정에 대한 갈등, 자신감부족, 외부 요인의 작용, 기술 부족, 집중력 감소, 긴장 및 불안감 증대 7개 영역이 확인되었다. 넷째, 방해요인에 따른 대처요인은 정신 집중, 자기위안, 자신감 갖기, 자기암시, 목표 설정, 자기확신, 몰입, 연습, 심상 훈련, 마인드 컨트롤, 무시, 이미지 트레이닝, 심호흡 14개 요인으로 나타났다. 특히 실패 및 실수에 대한 걱정의 방해요인에 대해서는 심호흡, 마인드 컨드롤, 정신 집중, 자기위안 순위로, 자신감이 부족할 때는 자신감, 자기암시 방법과 같은 순위로 대처하였다. 모든 선수들이 공통적으로 가장 많이 사용하는 방해요인과 대처요인은 자신감 부족, 실패나 실수 걱정 그리고 자신감 갖기, 심호흡으로 나타났다. 축구 지도자들은 이와 갈이 승부차기 시 경험하는 축구선수들의 다양한 심리적 특성을 충분히 숙지하여 훈련에 임함이 바람직하겠다.