        1.
        2023.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In the case of a school building, even though it is a regular structure in terms of plan shape, if the masonry infill wall acts as a lateral load resisting element, it can be determined as a torsionally irregular building. As a result, the strength and ductility of the structure are reduced, which may cause additional earthquake damage to the structure. Therefore, in this study, a structure similar to a school building with torsional irregularity was selected as an example structure and the damping performance of the PC-BRB was analyzed by adjusting the eccentricity according to the amount of masonry infilled wall. As a result of nonlinear dynamic analysis after seismic reinforcement, the torsional irregularity of each floor was reduced compared to before reinforcement, and the beams and column members of the collapse level satisfied the performance level due to the reduction of shear force and the reinforcement of stiffness. The energy dissipation of PC-BRB was similar in the REC-10 ~ REC-20 analytical models with an eccentricity of 20% or less. REC-25 with an eccentricity of 25% was the largest, and it is judged that it is effective to combine and apply PC-BRB when it has an eccentricity of 25% or more to control the torsional behavior.
        4,000원
        2.
        2017.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The demand for skyscrapers is increasing worldwide. Until now, various lateral resistance structures have been used for lateral displacement control of high-rise buildings. An outrigger damper system has been introduced recently to improve lateral dynamic response control performance further. However, a study of outrigger damper system is yet to be sufficiently investigated. In this study, time history analysis was performed to investigate the control performance of an outrigger damper system of high-rise building under eccentric loading. To do this, an actual scale 3-dimensional tall building model with an outrigger damper system was prepared. The control performance of the outrigger damper system was evaluated by varying stiffness and damping values. On the top floor torsional angle response to the earthquake load, was greatly affected by damping value. And the displacement response was affected greatly by the stiffness value and damping value of damper system. In conclusion, it is necessary to select the proper damping and stiffness values of the outrigger damper system.
        4,000원
        3.
        2013.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In the Korean Building Code (KBC), the Design Eccentricity involves the torsional amplification factor (TAF), and the inherent and accidental eccentricities. When a structure of less than 6-stories and assigned to seismic design category C or D is designed using equivalent static analysis method, both KBC-2006 and KBC-2009 use the TAF but apply different calculation methods for the of design eccentricity. The design eccentricity in KBC-2006 is calculated by multiplying the sum of inherent eccentricity and accidental eccentricity at each level by a TAF but that in KBC-2009 is calculated by multiplying only the accidental eccentricity by a TAF. In this paper, the damage indices of a building with planar structural irregularity designed by different design eccentricities are compared and the relationship between the earthquake damage and design eccentricity of the building is evaluated. On the basis of this study, the increment of design eccentricity results in the decrement of final eccentricity and global damage index of structure. It is observed that design eccentricity in KBC-2006 reduces the vulnerability of torsional irregular building compared to design eccentricity in KBC-2009.
        4,000원
        4.
        2013.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        For most of recent tall buildings, one characteristic is that their building shapes vary with height such as taper and setback, and this implies that the distribution of their structural components may also vary with height. Because of these structural variations, although the sectional shapes of these buildings are symmetric, it is difficult to say whether or not they are structurally symmetric. The acceleration responses of structurally asymmetric tall buildings are larger than those of non-eccentric buildings, thus raising the possibility of problems during strong winds and typhoons. This paper describes wind tunnel tests carried out using building models with height variations and acceleration response analyses, and discusses the resulting response characteristics. For tapered and setback buildings, although the across-wind accelerations are larger than those of a square building, the total root-mean-square accelerations remain small because of smaller along-wind and torsional rms accelerations. And it was found that the effects of statistical couplings between along-wind force and other two forces are negligible.
        4,000원
        5.
        2012.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        지진하중에 의해 발생하는 비정형 건물의 피해를 줄이기 위하여 내진설계기준에서는 비틀림 증폭계수를 도입하였다. 이 계수는 내진설계기준에 따라 다르게 적용되었으며 같은 시기의 설계기준에서조차 다르게 적용되었다. 본 연구에서는 서로 다른 설계편심으로 설계된 건물의 최종 정적편심의 크기, 연약단부의 횡강성과 비틀림 강성비를 비교하였다. 비틀림 증폭계수가 증가할수록 연약단부의횡강성이 증가하여 건물의 최종 정적편심의 크기는 감소하였으나 이 계수가 최대값 3.0에 도달한 이후부터 건물의 최종 정적편심의 크기는 다시 증가하였다. 우발편심과 정적편심의 합에 비틀림 증폭계수를 곱하여 구한 설계편심으로 설계된 건물의 최종 정적편심의 크기는수직부재의 위치에 따라 0 또는 음수로 측정되었다.
        4,000원
        6.
        2012.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 비틀림 거동을 일으키는 편심구조물의 효율적인 제어를 위한 비틀림 강성을 가지는 동조질량감쇠기의 제어성능을 검토하고자 한다. 이를 위하여 지진하중을 받는 편심구조물에 동조질량감쇠기의 설치위치와 비틀림강성에 따른 제어성능을 평가한다. 반복되는 시간이력해석시 소요되는 해석시간을 줄이기 위하여 등가해석 모델을 사용하였고 비비례감쇠시스템인 동조질량감쇠가 설치된 구조물의 해석을 효율적으로 수행할 수 있었다. 본 연구를 통하여 일반적인 동조질량감쇠기에서 무시되어온 동조질량감쇠기의 비틀림 속성이 비틀림 거동이 발생하는 편심구조물에서는 효과적일 수 있음을 검증하였다. 그리고 편심구조물의 경우에는 동조질량감쇠기의 최적 설치 위치가 구조물 평면의 중심이 아닐 수 있음을 확인하였다.
        4,000원
        7.
        2010.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        건물의 실제 편심은 일반적으로 계산된 값과 상당히 다르며, 정형 건물도 비틀림의 영향을 받는다. 질량분포의 비대칭성과 수직축에 대한 지반의 회전요소와 같은 요인들의 영향을 고려하고, 비틀림 비정형 건물의 취약성을 줄이기 위하여 내진설계규준에서는 우발편심과 비틀림 증폭계수를 도입하였다. 본 연구에서는 정형건물의 다양한 형상비와 평면중심으로부터의 부재위치에 따른 비틀림 증폭계수의 영향 및 이 계수에 영향을 미치는 요인을 확인하였고 보통암 지반에 위치한 다양한 편심과 형상비를 갖는 비선형 철근콘크리트 단층모델을 이용하여 비틀림 증폭계수를 검증하였다. 비선형 정적해석과 시간이력해석을 이용하여 구한 연약단부의 최대 정적변위와 동적변위는 비교적 일치하였으나 최대 정적비틀림과 동적비틀림의 차이는 편심크기가 작을수록 크게 나타났다. 1차 설계편심에 비틀림 증폭계수 적용유.무에 따라 연약단부 부재의 밑면전단력 증가가 미비하여 최대 정적변위의 증가비가 크지 않다.
        4,000원
        8.
        2010.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        비정형 평면을 가진 건물의 추가적인 손상의 원인이 되는 비틀림과 비정형성의 척도인 편심과의 관계에 대한 많은 연구들이 진행되어 왔으나 손상도와 편심의 직접적인 관계에 대한 연구는 수행된 적이 거의 없다. 본 연구에서는 비정형 평면을 가진 건물의 복잡한 지진 응답에 적용할 수 있는 3차원 손상도 계수를 이용하여 건물의 손상도와 편심에 대한 정량적인 관계를 분석하였다. 이를 통해 건물의 편심이 커지면 최대변위는 줄어들지만 비틀림 거동이 증가하여, 손상의 집중으로 인해 전반적인 손상도 계수가 증가함이 관찰되었다. 또한, 2차원 주기가 비슷한 경우에는, 건물의 길이가 최대변위와 최대 비틀림에 미치는 영향이 작으며 이로 인해 전체 손상도 계수에도 그 영향이 미미한 것으로 관찰되었다. 해석 결과를 바탕으로 중약진 지역에서 편심의 크기가 10%, 20%, 30%인 단층 건물은 편심이 없는 건물에 비해서 각각 평균 3~5%, 13~18%, 33~47% 정도의 손상도 증가가 있을 것으로 분석하였다. 이와 같은 편심-손상도 관계는비정형 평면을 가진 건물의 내진 설계에 있어서 기본 구조 계획 수립과 내진 성능 평가에 유용한 자료가 될 것으로 생각된다.
        4,000원
        9.
        2018.04 서비스 종료(열람 제한)
        In this study, the seismic performance of a Low-rise Pilotis Building with Eccentric Core is investigated. Low-rise Pilotis Buildings are very popular in Korea, but regarded as very weak structure to earthquake.
        10.
        2017.04 서비스 종료(열람 제한)
        Recently, Earthquake occurrence in korea has become frequent, and the seismic safety of low-rise piloti buildings becomes more and more important. In this study, the seismic retrofit method of low-rise eccentric core type piloti building structures using concrete filled steel tube (CFT) columns was analysed and verified for seismic performance.
        11.
        2017.01 KCI 등재 서비스 종료(열람 제한)
        Recently, Earthquake occurrence in korea has become frequent, and the seismic safety of low-rise piloti buildings becomes more and more important. In this study, the seismic retrofit method of low-rise eccentric core type piloti building structures using concrete filled steel tube (CFT) columns was analysed and verified for seismic performance.