검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 12

        1.
        2022.10 구독 인증기관·개인회원 무료
        The Nuclear Cycle Experiment Research Center is one of the facility of the Korea Atomic Energy Research Institute (KAERI). This facility is a laboratory-scale version of pyro-processing technology. Mixture depleted Uranium (DU) and depleted Uranium (DU) feed material are used in this facility for pyro-research. During summer, air conditioners that maintain temperature and humidity are always in operation to protect analysis equipments. 15 air conditioners are installed in this facility. The condensate which is generated in 15 air conditioners is collected in one place to analyze. Sampling was performed to check the level of contamination, U, pH and gamma radiation test were performed. This paper shows the degree of contamination of air conditioner condensate which is generated in the radiation management area.
        2.
        2020.08 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        HANARO (High-flux Advanced Neutron Application Reactor)는 우라늄의 핵분열 연쇄반응에서 생성된 중성자를 이용하여 다양한 연구개발을 수행하는 열출력 30 MW 규모의 연구용 원자로이다. 탈기탱크는 HANARO의 부속시설에 설치되어 있다. 탈기탱크는 내부환경요인으로 인해 기체오염물질을 발생시킨다. 탈기탱크는 기체오염물질을 허용 가능한 수준 이하로 유지하기위해 필요하며 기체시료채취판넬의 분석기에 의해 모니터링 된다. 응축수가 발생하여 기체시료채취판넬의 분석기 내부로 유입된다면, 분석기의 측정 챔버 내부에 부식이 발생하여 고장을 야기한다. 응축수의 생성 원인은 탈기탱크에 존재 하는 기체가 분석기로 유입되는 과정에서 탈기탱크와 분석기사이 온도 차이다. 응축수 생성을 억제하고 계통 내부에 생성 된 응축수를 효율적으로 제거하기 위해 탈기탱크와 기체시료채취판넬 사이에 히팅시스템이 설치되었다. 이 연구에서 우리는 히팅시스템의 효율성을 알고자 한다. 또한 Wall Condensation Model을 이용하여 유체 입구온도, 외부온도 및 히팅 케이블 설정온도 변화에 따른 파이프 온도와 평균응축량의 변화를 모델링하였다.
        4,000원
        3.
        2018.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        During indoor air conditioning, cold condensate is generated. But until recently, this condensate has not been recycled. This experiment and research is on the technology of the condensed water recycling in air conditioning. This study demonstrates the effect of condensate recycling, contributes to energy saving and water use reduction. For this purpose, the test equipment was installed to measure the temperature of the condensate generated in the fan-coil unit, and the performance of the high-pressure pump to be applied to the cooling pipe was examined. As a result, the water quality and energy saving effect.
        4,000원
        4.
        2014.02 구독 인증기관·개인회원 무료
        It is intended to develop an experimental apparatus which can visualize flow patterns in condensate water reuse system with various cross sections. PVC particles on fluid surface help to obtain clear flow images. The flow region that were found in the experiments are steady, unsteady and significantly-mixed flows.
        7.
        2015.06 KCI 등재 서비스 종료(열람 제한)
        LFG, generated by the decomposition of wastes, is very humid and has high temperature. When it cools during its transfer in the piping system, condensate forms, blocking the flow of LFG. Typical condensate removal devices, which works on the principle of trap usually used in the sewer pipe and utilizes water to prevent the intrusion of outer gas and to drain condensate, have limitation for their uses in landfill by the evaporation of water when it comes to dry condition in the landfill. In this study we investigated the temperature distribution in the waste layer and the possibility of the evaporation of water in the trap. LFG could be cooled down or heated by the temperature of waste layers where the transfer pipe locates. Evaporation rates, estimated by the use of temperature distribution in the landfill, were high enough to cause malfunctions when the difference of temperature between LFG and waste layer is high.
        10.
        2011.10 KCI 등재 서비스 종료(열람 제한)
        This study was carried out to investigate the inhibitory effect of Angelicae Dahuricae Radix (ADR) extract on chronic obstructive pulmonary disease (COPD) induced by cigarette smoke condensate (CSC) and lipopolysaccharide (LPS) in mice. COPD was induced by intratracheal instillation of LPS and CSC 5 times for 12 days; this increased airway hyperresoponsiveness (AHR) and inflammatory cells in bronchoalveolar lavage fluid (BALF). ADR extract was administered orally at a dose of 50 and 200 mg/kg. The concentration of imperatorin, a major component of ADR and therefore used as a measure of quality control, was 0.098%±0.018%. Treatment of the mice with ADR extract (50 and 200 mg/kg) alleviated AHR and reduced inflammatory cell counts. Treatment with cyclosporin A (CSA; 10 mg/kg) also modulated AHR and reduced inflammatory cells effectively. Compared with CSA treatment, treatment with ADR (50 mg/kg) extract reduced neutrophil and CD4+/CD3+ cell counts by 22.67% and 44.92%, respectively. In addition, compared with CSA treatment, treatment ADR 200 mg/kg reduced neutrophils, CD4+/CD3+ cells and CD8+/CD3+ cells, by 32.10%, 83.17% and 82.11%, respectively. These results indicate that ADR extract may have an inhibitory effect on COPD induced by LPS and CSC in mice.