검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 2

        1.
        2024.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, fire extinguisher system to which form fire extinguisher agents were adopted was applied to the combat vehicle crew room to apply fire extinguishing performance and acid gas safety that meet the national defense standards. As a result of evaluation and verification, the following conclusions were drawn. For standard fire sizes in the combat vehicle crew's standard model, we ignited using a mixture of Novec 1230 and Halon 1301 form extinguisher agent and released form extinguisher agent after 30 seconds to determine the fire extinguishing time. The amount of acid gas generated met the criteria in all cases. When the fire size was increased to 0.12m2 and a 2.0mm nozzle was used, all of the extinguishing time, the amount of acid gas generated, and the concentration of Novec 1230 met the criteria. Despite the more difficult conditions to extinguish the fire by making the fire larger, it was possible to confirm the extinguishing performance of the Novec 1230 form extinguisher agent and its safety against acid gas.
        4,000원
        2.
        2023.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Combat-armored vehicles were equipped with an automatic-fire-extinguishing system to ensure the safety of the crew and vehicle from fires on the vehicle. When a fire was occurred, the automatic-fire-extinguishing system automatically detects the fire through sensors and detection lines, sprays a fire extinguisher, and notifies the crew visually and audibly. Recently, there had been cases of automatic-fire-extinguishing systems malfunction on combat-armored vehicles. In this study, in order to resolve the automatic-fire-extinguisher's malfunction phenomenon, ground noise and inter-circuit noise generated from the fire detection line were identified, and the resistance connected on the circuit was revised to remove noise. As a result of resistance revision, the noises was eliminated and the electromotive force difference between input circuits was made constant, thereby improving the malfunction of the automatic-fire-extinguishing system. By applying the result, it was confirmed that the control device sensed a temperature similar to the actual temperature on actual vehicles, and it was confirmed that the automatic-fire-extinguishing system's malfunction phenomenon was not founded in the field vehicles after then.
        4,000원