검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 12

        2.
        2023.11 구독 인증기관·개인회원 무료
        Concrete is the primary building material for nuclear facilities, making it one of the most common forms of radioactive waste generated when decommissioning a nuclear facility. Of the total waste generated at the Connecticut Yankee and Maine Yankee nuclear power plants in the United States, concrete waste accounts for 83.5% of the total for Connecticut Yankee and 52% for Maine Yankee. In order to dispose of the low- to medium-level radioactive concrete waste generated during the decommissioning of nuclear power plants, it is necessary to analyze the radioactivity concentration of gamma nuclides such as Co-58, Co-60, Cs-137, and Ce-144. Gamma-ray spectroscopy is commonly used method to measure the radioactivity concentration of gamma nuclides in the radioactive waste; however, due to the nature of gamma detectors, gamma rays from sequentially decaying nuclides such as Co-60 or Y-88 are subject to True Coincidence Summing (TCS). TCS reduces the Full Energy Peak Efficiency (FEPE) of specific gamma ray and it can cause underestimation of radioactivity concentration. Therefor the TCS effect must be compensated for in order to accurately assess the radioactivity of the sample. In addition, samples with high density and large volume will experience a certain level of self-shielding effect of gamma rays, so this must also be compensated for. The Radioactive Waste Chemical Analysis Center at the Korea Atomic Energy Research Institute performs nuclide analysis for the final disposal of low- and intermediate-level concrete waste. Since a large number of samples must be analyzed within the facility, the analytical method must simultaneously satisfy accuracy and speed. In this study, we report on the results of evaluating the accuracy of the radioactivity concentration correction by applying an efficiency transfer method that appears to satisfy these requirements to concrete standard reference material.
        3.
        2023.11 구독 인증기관·개인회원 무료
        The inorganic scintillator used in gamma spectroscopy must have good efficiency in converting the kinetic energy of charged particles into light as well as high light output and high light detection efficiency. Accordingly, various studies have been conducted to enhance the net-efficiency. One way to improve the light yield has been studied by coating scintillators with various nanoparticles, so that the scintillation light can undergo resonance on surface between scintillators and nanoparticles resulting in higher light yield. In this study, an inorganic scintillator coated with CsPbBr3 perovskite nanocrystals using dip coating technique was proposed to improve scintillation light yield. The experiment was carried out by measuring scintillation light output, as the result of interaction between inorganic scintillator coated with CsPbBr3 perovskite nanocrystals and gamma-ray emitted from Cs-137 gamma source. The experimental results show that the channel corresponding to 662 keV full energy peak in the Cs-137 spectrum shifted to the right by 14.37%. Further study will be conducted to investigate the detailed relationships between the scintillation light yield and the characteristics of coated perovskite nanoparticles, such as diameter of nanoparticles, coated area ratio and width of coated region.
        4.
        2023.05 구독 인증기관·개인회원 무료
        Some of the metal waste generated from KEPCO NF is being disposed of in the form of ingots. An ingot is a metal that is melted once and then poured into a mold to harden, and it is characterized by a uniform distribution of radioactive material. When measuring the uranium radioactivity in metal ingot with HPGe detector, 185.7 keV of U-235 is used typically because most gamma rays emitted at U-235 are distributed in low-energy regions below 200 keV. To analyze radioactivity concentration of U-235 with HPGe detector more accurately, self-attenuation due to geometrical differences between the calibration source and the sample must be corrected. In this study, the MCNP code was used to simulate the HPGe gamma spectroscopy system, and various processes were performed to prove the correlation with the actual values. First an metal ingottype standard source was manufactured for efficiency calibration, and the GEB coefficient was derived using Origin program. And through the comparison of actual measurements and simulations, the thickness of the detector’s dead layers were defined in all directions of Ge crystal. Additionally instead of making an metal ingot-type standard source every time, we analyzed the measurement tendency between commercially available HPGe calibration source (Marinelli beaker type) and the sample (metal ingot type), and derived the correction factor for geometry differences. Lastly the correction factor was taken into consideration when obtaining the uranium radioactivity concentration in the metal ingot with HPGe gamma spectroscopy. In conclusion, the U-235 radioactivity in metal ingot was underestimated about 25% of content due to the self-attenuation. Therefore it is reasonable to reflect this correction factor in the calculation of U-235 radioactivity concentration.
        5.
        2022.10 구독 인증기관·개인회원 무료
        Plastic scintillators can be used to find radioactive sources for portal monitoring due to their advantages such as faster decay time, non-hygroscopicity, relatively low manufacturing cost, robustness, and easy processing. However, plastic scintillators have too low density and effective atomic number, and they are not appropriate to be used to identify radionuclides directly. In this study, we devise the radiation sensor using a plastic scintillator with holes filled with bismuth nanoparticles to make up for the limitations of plastic materials. We use MCNP (Monte Carlo N-particle) simulating program to confirm the performance of bismuth nanoparticles in the plastic scintillators. The photoelectric peak is found in the bismuth-loaded plastic scintillator by subtracting the energy spectrum from that of the standard plastic scintillator. The height and diameter of the simulated plastic scintillator are 3 and 5 cm, respectively, and it has 19 holes whose depth and diameter are 2.5 and 0.2 cm, respectively. As a gamma-ray source, Cs-137 which emits 662 keV energy is used. The clear energy peak is observed in the subtracted spectrum, the full width at half maximum (FWHM) and the energy resolution are calculated to evaluate the performance of the proposed radiation sensor. The FWHM of the peak and the energy resolution are 61.18 keV and 9.242% at 662 keV, respectively.
        6.
        2022.05 구독 인증기관·개인회원 무료
        Gamma-ray spectroscopy, which is an appropriate method to identify and quantify radionuclides, is widely utilized in radiological leakage monitoring of nuclear facilities, assay of radioactive wastes, and decontamination evaluation of post-processing such as decommissioning and remediation. For example, in the post-processing, it is conducted to verify the radioactivity level of the site before and after the work and decide to recycle or dispose the generated waste. For an accurate evaluation of gamma-ray emitting radionuclides, the measurement should be carried out near the region of interest on site, or a sample analysis should be performed in the laboratory. However, the region is inaccessible due to the safety-critical nature of nuclear facilities, and excessive radiation exposure to workers could be caused. In addition, in the case of subjects that may be contaminated inside such as pipe structures generated during decommissioning, surveying is usually done over the outside of them only, so the effectiveness of the result is limited. Thus, there is a need to develop a radiation measurement system that can be available in narrow space and can sense remotely with excellent performance. A liquid light guide (LLG), unlike typical optical fiber, is a light guide which has a liquid core. It has superior light transmissivity than any optical fiber and can be manufactured with a larger diameter. Additionally, it can deliver light with much greater intensity with very low attenuation along the length because there is no packing fraction and it has very high radiation resistant characteristics. Especially, thanks to the good transmissivity in UV-VIS wavelength, the LLG can well transmit the scintillation light signals from scintillators that have relatively short emission wavelengths, such as LaBr3:Ce and CeBr3. In this study, we developed a radiation sensor system based on a LLG for remote gamma-ray spectroscopy. We fabricated a radiation sensor with LaBr3:Ce scintillator and LLG, and acquired energy spectra of Cs-137 and Co-60 remotely. Furthermore, the results of gamma-ray spectroscopy using different lengths of LLG were compared with those obtained without LLG. Energy resolutions were estimated as 7.67%, 4.90%, and 4.81% at 662, 1,173, and 1,332 keV, respectively for 1 m long LLG, which shows similar values of a general NaI(Tl) scintillator. With 3 m long LLG, the energy resolutions were 7.92%, 5.48%, and 5.07% for 662, 1,173, and 1,332 keV gamma-rays, respectively.
        11.
        2019.09 KCI 등재 SCOPUS 서비스 종료(열람 제한)
        This paper is a part of the series on positron annihilation spectroscopy of two-phase diffuse gas-and-dust aggregates, such as interstellar medium and the young remnants of type II supernovae. The results obtained from prior studies were applied here to detect the relationship between the processes of the annihilation of the K-shell electrons and incident positrons, and the effects of these processes on the optical spectra of their respective atoms. Particular attention was paid to the Doppler broadening of their optical lines. The relationship between the atomic mass of the elements and the Doppler broadening, ΔλD (Å), of their emission lines as produced in these processes was established. This relationship is also illustrated for isotope sets of light elements, namely 3 6 7 7 9 10 11 2 3 3 4 4 5 5 He, Li, Li, Be, Be, B, and B. A direct correlation between the γ-line luminosity ( Eγ =1.022 MeV) and D Δλ (Å) was proved virtually. Qualitative estimates of the structure of such lines depending on the positron velocity distribution function, f(E), were made. The results are presented in tabular form and can be used to set up the objectives of further studies on active galactic nuclei and young remnants of type II supernovae.
        12.
        2009.06 KCI 등재 SCOPUS 서비스 종료(열람 제한)
        ESR spectroscopy에 의한 방사선 조사 건조향신료의 조사여부의 정확한 판별에 필요한 기초자료를 얻고자 방사선 조사 유래의 cellulose radical에 대한 parameter를 분석하였다. 건조향신료 분말 4종(고추, 마늘, 양파, 후추)에 대하여 0, 1, 5, 10 kGy의 감마선을 조사한 후 ESR signal을 분석하였다. 방사선 조사된 4종의 건조향신료는 모두 방사선 조사 유래의 triplet signal인 cellulo