검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 10

        3.
        2022.10 구독 인증기관·개인회원 무료
        The safe, efficient and cost-effective decommissioning and dismantling of radioactive facilities requires the accurate characterization of the radionuclide activities and dose rate environment. And it is critical across many nuclear industries to identify and locate sources of radiation accurately and quickly. One of the more challenging aspects of dealing with radiation is that you cannot see it directly, which can result in potential exposure when working in those environments. Generally, semiconductor detectors have better energy resolution than scintillation detectors, but the maximum achievable count rates are limited by long pulse signals. Whereas some high pure germanium detectors have been developed to operate at high count rates, and these HPGe detectors could obtain gamma-ray spectra at high count rates exceeding 1 Mcps. However, HPGe detectors require cooling devices to reduce the leak currents, which becomes disadvantageous when developing portable radiation detectors. Furthermore, chemicalcompound semiconductor detectors made of cadmium telluride and cadmium zinc telluride are popular, because they have good energy resolution and are available at room temperature. However, CdTe and CZT detectors develop irradiation-induced defects under intense gamma-ray fields. In this Review, we start with the fundamentals of gamma rays detection and review the recent developments in scintillators gamma-ray detectors. The key factors affecting the detector performance are summarized. We also give an outlook on the field, with emphasis on the challenges to be overcome.
        6.
        2016.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study carried out fiber damage detections of laminated GFRP plate structures using a modified bi-variate Gamma function. The effects of different layup sequences of composites on the fiber damage detection are studied using the finite element commercial package and genetic algorithm. Four unknown parameters are considered to determine the shape of the damage distribution, which is a modified form of the bivariate Gamma density distribution function. The sample studies show the excellence of the proposed method from the standpoints of its computation efficiency as well as its ability to determine the complex shape of an arbitrary stiffness degradation distribution.
        4,000원
        7.
        2013.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 비허용 품목인 유지종실류 5종(달맞이꽃씨, 홍화씨, 유채씨, 해바라기씨 및 아마씨)을 선정하여 광자 극발광법(PSL), 열발광법(TL), 전자스핀공명법(ESR) 및 기체크로마토그래프/질량분석법(GC/MS)을 활용하여 검지 특성 연구를 수행하였다. PSL 및 TL 측정 결과, 5종 모두 적용 가능성이 높은 것으로 판단하였다. ESR 분석결과는 5종 모두 조사시료에서 조사유래의 특이 ESR signal이 관찰되지 않아 적용 가능성이 낮다고 판단하였다. GC/MS 분석 결과, 홍화씨, 유채씨, 해바라기씨 및 아마씨의 경우에는 조사 유래의 hydrocarbon류가 검출되어 적용 가능성이 높은 것으로 판단하였다. 특히, oleic acid에서 유도된 8-heptadecene (C17:1), 1,7-hexadecadiene (C16:2)이 조사 여부를 확인하는 화학적 마커로 활용 가능성이 높았다. 달맞이꽃씨 경우에는 oleic acid에서 유도된 hydrocarbon류가 검출되지 않아 적용 가능성이 낮다고 판단하였다. 또한, 달맞이꽃씨, 홍화씨 및 해바라기씨에서 감마리놀렌산의 주요 원료인 linoleic acid에서 유도된 1,7,10-hexadecatriene (C16:3)과 6,9-heptadecadiene (C17:2)이 검출되어 조사여부를 확인하는 화학적 검지 마커로 활용 가능성이 높다고 판단 하였다. 본 연구 결과를 통해 유지종실류 5종에 대한 적용 가능성 및 다중분석 체계(PSL-TL-GC/MS)를 확립하였다.
        4,000원