검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 2

        1.
        2016.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Although the Hazen-Williams C factors are very important in the design, operation, and maintenance of water supply pipes, sufficient studies for them have been not reported in korea, which are based on experiments or measured data. Because of this, we have estimated C factors by measurement considering constraints in time precise safety diagnosis for multi-regional water supply system were performed. In this study, we confirmed constraints and variables characteristics of Hazen-Williams equation, and collected reliable C factors data of 174 by measurement, and analyzed their characteristics. According to collected data, the average value is 115.35, which is almost equal to the value of design standard or a little higher than it in korea. Also, among the equations suggested to determine C factor in the past, the C factors calculated by Sharp and Walski equation was closest to them in this study. In addition, to analyze collected C factors, use year and pipe diameter having high correlation with them were respectively divided into there categories. Analysis results showed that C factors evidently decreases depending on increases in use year, on the other hand, size of pipe diameter is proportional to value of them. In conclusion, this research showing evaluation and characteristics for C factors based on measured data will be used as practical reference in determining C factor in multi-regional water supply systems at a later date.
        4,000원
        2.
        2015.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, Hazen-Williams C value of pipes in wide waterworks system was estimated and statistically analyzed. Hazen-Williams C value of water pipe was predicted after 20 years of service period. From the results, it was found that C value of water pipe for treated water maintained higher value of 110 after 20 years of installation. Furthermore, it was found that velocity coefficients of steel pipe for less than and more than 20 years of installation were 117.7 and 109.3, respectively. C value of ductile iron pipe for less than and more than 20 years of installation were 118.1 and 114.2, respectively. In this study, it was also found that small value of C is used in the design of water pipe system. Therefore, excessively bigger size of pipe can be determined in the design of water pipe system. From the results of present study, optimum value of C can be used to avoid the oversized design of water pipe system.
        4,000원